Permit Application Status

PRRES20221783


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20221783
Building Permit - Residential
Certificate of Occupancy
TRUMARK HOMES LLC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT (FULL BASEMENT). COVERED DECK.
04/29/2022
06/09/2022
10/30/2022
08/10/2023
Locations
Contacts
TRUMARK HOMES, LLC, Address:424 SE MAXWELL DR, Phone:(816) 564-5613  
MARK A YANCIK, Address:508 nw manor dr  
TRUMARK HOMES LLC, Address:508 NW MANOR DR  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
TRUMARKHOMES.MARK@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $390.00 $390.00 Paid 06/09/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 06/09/2022
Water Meter Fee $479.24 $479.24 Paid 06/09/2022
Right of Way Permit Fee $85.00 $85.00 Paid 06/09/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/09/2022
Valuation Fee New Single Family $1,169.23 $1,169.23 Paid 06/09/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 6/29/2022 06/29/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/29/2022
DEFICIENT EROSION CONTROL INSTALLATION. RESTORE EROSION CONTROL ALONG THE STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Footing Inspection - Residential Passed 06/29/2022
Informational
06/29/2022
FOOTING APPROVED BY ENGINEER
Underslab Plumbing Inspection - Residential Passed 6/29/2022 6/29/2022 06/29/2022
Piers/Caissons Inspection - Residential Passed 7/14/2022 (8:00) 7/14/2022 07/14/2022
Sewer Service Inspection - R Passed 7/20/2022 (9:30) 7/20/2022 07/20/2022
Water Service Inspection - R Failed 7/20/2022 (10:00) 7/20/2022 07/20/2022
Misc
Corrective Action Required
07/20/2022
-WATER SERVICE LINE MUST BE MIN 42" BELOW GRADE. CURRENTLY AT 27" FROM GRADE AT FOUNDATION WALL
Electrical Service Inspection Passed 10/17/2022 10/17/2022 10/17/2022
Gas Service Inspection - Residential Passed 10/17/2022 10/17/2022 10/17/2022
All Rough Inspection - Residential Failed 10/17/2022 10/17/2022 10/17/2022
Miscellaneous Correction
Corrective Action Required
10/17/2022
-Unable to verify PFH nailing pattern -Install and flash all missing windows -seal upward penetration at garage soffit framing to attic spaces -Sister or replace over notched stud at garage west and east walls -Provide anchor bolt at end of plate west wall -Tighten anchor bolts -Strap top plates lapped less than 24” at garage walls -Seal top plate penetration at pantry -Provide lateral restraint for joists above load bearing walls -Seal penetration at top plate stair landing in garage -Address roof load bearing on ceiling joists in garage -Seal top plate penetrations at kitchen -Seal plate penetration at pantry exterior wall -Secure 2”’ and smaller dwv at midpoint -Fireblock tub trap —Seal op and bottom plate penetrations at master bath -Protect dryer duct 2” below top plate -Provide proper slope at vent piping in attic space throughout -Seao stud penetrations at return air spaces throughout -SEAL ALL PLATE AND FLOOR PENETRATIONS THROUGHOUT -Address concrete form board used as ridge in bed 2 -Address studs short of top plate at load bearing wall in basement stairwell -Fireblock top of furout wall from joist space at stairs and electrical panel -Fireblock dead so at column -Return air at bed 4 is dead a end -Seal joist/ stud penetrations at all return air -Address holes bored closer than 2” and closer than 2” to bottom of joist in bed 4 pex -Seal fireblocking at furout walls bed 4 -Tighten anchor bolts near sump pump
All Rough Inspection - Residential Passed 10/21/2022 10/21/2022 10/21/2022
Miscellaneous Correction
Resolved
10/21/2022
Driveway Inspection Partial 10/28/2022 10/28/2022
Misc
Informational
10/28/2022
10-28-22 AN form are in place and rock is compacted
Driveway Inspection Passed 10/31/2022 10/31/2022 11/04/2022
Misc
Informational
10/28/2022
10-28-22 AN form are in place and rock is compacted 10-4-22 AN driveway looks good
Erosion Control Inspection Residential Passed 07/03/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
07/03/2023
DEFICIENT EROSION CONTROL INSTALLATION. RESTORE EROSION CONTROL ALONG THE STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 7/3/2023 7/3/2023 07/03/2023
Misc
Corrective Action Required
07/03/2023
-Provide permanent address -Fix flashing above window trim not properly installed; seal gap -Provide manufacturer ratings label for AC. Label missing -Drive the grounding rod and bury the grounding clamp into ground as required -Seal above meter; seal exterior lights -Furnace receptacle must be gfci-protected or dedicated -Protect the enclosed and accessible space underneath foyer stair with 1/2” gypsum board
Water Service Inspection - R Passed 07/03/2023
Misc
Resolved
07/03/2023
-WATER SERVICE LINE MUST BE MIN 42" BELOW GRADE. CURRENTLY AT 27" FROM GRADE AT FOUNDATION WALL
Occupancy Inspection - Codes Residential Full C of O 8/10/2023 8/10/2023 08/10/2023
Misc
Resolved
08/10/2023
-Provide permanent address -Fix flashing above window trim not properly installed; seal gap -Provide manufacturer ratings label for AC. Label missing -Drive the grounding rod and bury the grounding clamp into ground as required -Seal above meter; seal exterior lights -Furnace receptacle must be gfci-protected or dedicated -Protect the enclosed and accessible space underneath foyer stair with 1/2” gypsum board
Documents & Images
Date Uploaded File Type Document Name
04/29/2022 Application Form SKM_C36822042911540
04/29/2022 Application Form SKM_C36822042911550
05/03/2022 Permit Codes Residential Plan Review
05/05/2022 Plot Plan APPROVED PLOT PLAN
05/09/2022 Approved Plans APPROVED PLANS
05/09/2022 Permit Codes Residential Plan Review
06/09/2022 Permit DS Building Permit
06/09/2022 Receipt Receipt for transaction:2022-004482
06/13/2022 M L Crose 1117 NE Goshen Dr LSMO Monticello 3rd Party Footing Inspection Report 6-10-22
06/13/2022 M L Crose 1117 NE Goshen Ct LSMO Monticello 3rd Party Footing Inspection Report 6-10-22
06/13/2022 M L Crose 1117 NE Goshen Ct LSMO Monticello 3rd Party Footing Inspection Report 6-10-22
06/29/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/20/2022 Letter INSPECTION SUMMARY
07/20/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
10/28/2022 Letter INSPECTION SUMMARY
11/04/2022 Letter INSPECTION SUMMARY
07/03/2023 Letter INSPECTION SUMMARY
07/03/2023 Letter INSPECTION SUMMARY
07/03/2023 Letter INSPECTION SUMMARY
08/10/2023 Letter Field Certificate of Occupancy
08/10/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home