Summary
PRRES20221737
Building Permit - Residential
Certificate of Occupancy
TRUMARK HOMES LLC
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED DECK
04/28/2022
05/23/2022
10/25/2022
08/10/2023
Locations
Contacts
TRUMARK HOMES, LLC, Address:PO BOX 728, Phone:(816) 564-5613  
TRUMARK HOMES LLC, Address:508 NW MANOR DR  
MARK A YANCIK, Address:508 nw manor dr  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,279.99 $1,279.99 Paid 05/23/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 05/23/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/23/2022
8331507-Sewer Connection Fee $570.00 $570.00 Paid 05/23/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 05/23/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 05/23/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 6/6/2022 6/6/2022 06/06/2022
Sewer Service Inspection - R Passed 6/17/2022 06/17/2022
Water Service Inspection - R Partial 6/17/2022 06/17/2022
Water Service Inspection - R Passed 6/20/2022 (9:00) 6/20/2022 06/20/2022
Piers/Caissons Inspection - Residential Passed 7/14/2022 (8:00) 7/14/2022 07/14/2022
Footing Inspection - Residential Passed 08/15/2022
Informational
08/15/2022
FOOTING APPROVED BY ENGINEER
Electrical Service Inspection Passed 8/15/2022 8/15/2022 08/15/2022
Gas Service Inspection - Residential Passed 8/15/2022 8/15/2022 08/15/2022
All Rough Inspection - Residential Failed 8/15/2022 8/15/2022 08/15/2022
Misc
Corrective Action Required
08/15/2022
-Nail siding to sill plates per code at front -Install windows and doors and nail siding per code -Provide attic access to roof space above garage -Support valley rafter above garage -Provide min 2 anchors for garage column -Over notched joist above garage near I beam -Fb duct chase from joist space -Solid block joist ends above bearing wall -Fb floor at plumbing trap; Fb plumbing space in office from soffit&joist space -Seal gaps along studs of return air space at front 2nd fl bathroom; Fb gap at top of this double stud wall -Install hangers at lvl beam connections above hallway bathroom -Move all roof purlin load off the non-bearing wall -Above master closet, nail one not-fully-nailed joist hanger and add more fasteners to 7/16” sheathing to tie rafters to ceiling joists -Reduce span of hip rafter above master bathroom -Fb basement bathroom wall from joist **OK TO INSULATE
All Rough Inspection - Residential Failed 8/19/2022 08/19/2022
Misc
Corrective Action Required
08/15/2022
-Install windows and doors and nail siding per code -Provide attic access to roof space above garage **Need min 30” headroom clearance -Provide min 2 anchors for garage column -Over notched joist above garage near I beam -Fb duct chase from joist space -Fb floor at plumbing trap; Fb plumbing space in office from soffit&joist space -Seal gaps along studs of return air space at front 2nd fl bathroom **OK TO INSULATE
All Rough Inspection - Residential Passed 8/22/2022 8/22/2022 08/22/2022
Misc
Resolved
08/22/2022
-Install windows and doors and nail siding per code -Seal gaps along studs of return air space at front 2nd fl bathroom **OK TO INSULATE
Driveway Inspection Passed 10/12/2022 10/12/2022 10/17/2022
Misc
Informational
10/17/2022
10-17-22 AN driveway looks good
All Rough Inspection - Residential Failed 10/31/2022 10/31/2022 10/31/2022
Misc
Corrective Action Required
10/31/2022
DECK ONLY - open electrical box over deck
Plot Plan Inspection Passed 2/10/2023 02/10/2023
All Rough Inspection - Residential Passed 02/13/2023
Misc
Resolved
02/13/2023
DECK ONLY - open electrical box over deck
Occupancy Inspection - Codes Residential Failed 2/13/2023 2/13/2023 02/13/2023
Misc
Corrective Action Required
02/13/2023
-Shim gap at deck joist hangers -Provide graspable handrail no wider than 3.5”for deck stair -Provide an outdoor receptacle accessible from grade and within 6.5 ft of grade at back of dwelling -Paint gas service piping to protect against corrosion -Provide sewer tracer wire port at grade -Provide max 35 amp breaker for AC unit circuit
Occupancy Inspection - Codes Residential Full C of O 8/10/2023 8/10/2023 08/10/2023
Misc
Resolved
08/10/2023
Documents & Images
Date Uploaded File Type Document Name
04/28/2022 SKM_C36822042606330
04/28/2022 SKM_C36822042606320
04/28/2022 Permit Codes Residential Plan Review
05/02/2022 Letter Codes Residential Plan Review
05/03/2022 Approved Plans Approved Drawings
05/11/2022 Plot Plan Approved Plot Plan
05/11/2022 Permit Codes Residential Plan Review
05/13/2022 4732 NE Freehold Dr LSMO MC Lot 148 Trumark P 2022-1737 3rd Party Footing Inspection Report 5-13-22
05/23/2022 Permit DS Building Permit
05/23/2022 Receipt Receipt for transaction:2022-003837
06/06/2022 Letter INSPECTION SUMMARY
06/17/2022 Letter INSPECTION SUMMARY
06/17/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
08/15/2022 Letter INSPECTION SUMMARY
08/15/2022 Letter INSPECTION SUMMARY
08/15/2022 Letter INSPECTION SUMMARY
08/15/2022 Letter INSPECTION SUMMARY
08/19/2022 Letter INSPECTION SUMMARY
08/22/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/31/2022 Letter INSPECTION SUMMARY
02/09/2023 NextDocument (150) AS GRADED PLOT PLAN LOT 148 MONTICELLO
02/09/2023 Plot Plan APPROVED AS GRADED PLOT PLAN
02/10/2023 Letter INSPECTION SUMMARY
02/13/2023 Letter INSPECTION SUMMARY
02/13/2023 Letter INSPECTION SUMMARY
08/10/2023 Letter Field Certificate of Occupancy
08/10/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home