Summary
PRRES20221225
Building Permit - Residential
Certificate of Occupancy
ACH DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED/UNCOVERED PATIO
03/31/2022
04/04/2022
10/01/2022
06/08/2023
Locations
Contacts
A PLACE CALLED HOME CONSTRUCTION CO INC, Address:804 SE WILLOW PL, Phone:(816) 365-4663  
ACH DEVELOPMENT LLC, Address:3170 NE CARNEGIE DR STE 400  
Randy Gish, Address:804 SE WILLOW PL, Phone:(816) 365-4663  
MCDANIEL FURNACE & SHEET METAL, Address:2905 S M 291 FRONTAGE RD, Phone:(816) 373-6370  
CROWN ELECTRICAL SERVICES, Address:1213 SE 11TH TER, Phone:(816) 272-5379  
ACCU-PLUMBING INC, Address:PO BOX 683, Phone:(816) 229-4776  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,156.88 $1,156.88 Paid 04/04/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 04/04/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/04/2022
8331507-Sewer Connection Fee $390.00 $390.00 Paid 04/04/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 04/04/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 04/04/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/31/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/18/2022 (2:00) 5/18/2022 05/18/2022
Erosion Control Inspection Residential Failed 6/1/2022 06/01/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/01/2022
-ON 6/1-IT WAS OBSERVED THAT ABI CONTRACTOR WAS TRACKING MUD AND DEBRIS OUT ONTO THE STREET. STREET SHALL BE CLEANED UP WITHIN TWO WORKING DAYS. MIN 3/4" GRAVEL MIN 6" DEEP SHALL BE PROVIDED AT LOT ENTRANCE. -DEFICIENT EROSION CONTROL INSTALLATION SHALL BE CORRECTED NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Erosion Control Inspection Residential Failed 7/1/2022 07/01/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/01/2022
-PROVIDE MIN 3/4" & 6" DEEP OF GRAVEL AT LOT ENTRANCE. -RESTORE EROSION CONTROL ALONG THE STREET. REPLACE FLAT WATTLE EROSION CONTROL THAT HAS BEEN DRIVEN OVER NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Failed 7/1/2022 7/1/2022 07/01/2022
Misc
Corrective Action Required
07/01/2022
INSPECTION DENIED. TAKE CARE OF THE EROSION CONTROL BEFORE SCHEDULING AN INSPECTION
Underslab Plumbing Inspection - Residential Passed 7/21/2022 7/21/2022 07/21/2022
Misc
Resolved
07/21/2022
INSPECTION DENIED. TAKE CARE OF THE EROSION CONTROL BEFORE SCHEDULING AN INSPECTION
Water Service Inspection - R Passed 10/14/2022 10/14/2022
Sewer Service Inspection - R Passed 10/17/2022 (1:00) 10/17/2022 10/17/2022
Gas Service Inspection - Residential Passed 10/21/2022 10/21/2022 10/21/2022
Piers/Caissons Inspection - Residential Passed 11/10/2022 11/10/2022
Electrical Service Inspection Failed 11/23/2022 11/23/2022 11/23/2022
Misc
Corrective Action Required
11/23/2022
-Only one grounding conductor connection at each grounding clamp -Ufer grounding electrode conductor shall be run continuously and connected to the outside service disconnect per code -Provide a 4-conductor SE cable feeder to the basement sub-panel, with the insulated grounded conductor for the grounded bus bar and bare conductor for the grounding bus bar -Secure all wiring within 12” of sub-panel
All Rough Inspection - Residential Failed 11/23/2022 11/23/2022 11/23/2022
Misc
Corrective Action Required
11/23/2022
-Fasten siding to sill plates @6” oc, not 8”-10” -Install tension straps at garage PFH walls per code -Protect dryer circuit at laundry room -Secure steel column to I beam -Provide security blocking at patio exterior door -Provide wall receptacle spaced per code at rear great room wall -Route electrical cable through grommet connector at entry into fireplace -Strap wall top plate lapped less than two ft at hallway bathroom -Support roof above master closet -Nail corner studs at master closet -Provide wall receptacles spaced per code near wet bar -Securely fasten SE cable every 4.5 ft or less, not just laying the cable on framing -Fb basement wall space from soffit space -Extend bedroom 4 supply duct to ceiling level Install double joist below bearing wall between bedrooms 2&3. Should not cut the rafters -Code requires studs to be continuous from floor to ceiling. You have wall corner-to-corner window headers all along the rear exterior wall. Have engineer address this **OK TO INSULATE
All Rough Inspection - Residential Partial 12/1/2022 12/1/2022 12/01/2022
Misc
Corrective Action Required
11/23/2022
-Secure steel column to I beam at dining/stair **OK TO ROCK
Driveway Inspection Partial 12/5/2022 12/5/2022 12/05/2022
Misc
Informational
12/05/2022
12-5-22 AN forms are in place and aggregate is present and compacted
Sidewalk Inspection Partial 12/5/2022 12/5/2022 12/05/2022
Misc
Informational
12/05/2022
12-5-22 AN forms are in place and aggregate is present and compacted
All Rough Inspection - Residential Passed 12/16/2022 12/16/2022 12/16/2022
Misc
Resolved
12/16/2022
-Secure steel column to I beam at dining/stair **OK TO ROCK
Electrical Service Inspection Passed 12/29/2022 12/29/2022 12/29/2022
Misc
Resolved
12/29/2022
-Only one grounding conductor connection at each grounding clamp -Ufer grounding electrode conductor shall be run continuously and connected to the outside service disconnect per code -Provide a 4-conductor SE cable feeder to the basement sub-panel, with the insulated grounded conductor for the grounded bus bar and bare conductor for the grounding bus bar -Secure all wiring within 12” of sub-panel
Driveway Inspection Passed 12/8/2022 4/10/2023 04/10/2023
Misc
Informational
12/05/2022
12-5-22 AN forms are in place and aggregate is present and compacted 4-10-23 Site visited and it appears Driveway and Sidewalk pass.
Sidewalk Inspection Passed 12/8/2022 4/10/2023 04/10/2023
Misc
Informational
12/05/2022
12-5-22 AN forms are in place and aggregate is present and compacted 4-10-23 NS Site visited and it appears Driveway and Sidewalk pass.
Occupancy Inspection - Codes Residential Failed 5/23/2023 5/23/2023 05/23/2023
Misc
Corrective Action Required
05/23/2023
-Obtain lawn irrigation permit and submit backflow valve test report to city -Provide sewer tracer wire port at grade -Provide min 3 ft sump pump extension from building -Move the downspout discharge away from AC unit -Secure AC whip within 12” of disconnect -Seal above AC disconnect -Paint gas service piping -Provide box extension for all electrical boxes recessed more than 1/4” behind non-combustible wall finish -Provide gfci protection for clothes washer receptacle -Provide security strike plate that comes with this door. Screw the exterior door embedded jamb brace into studs -Install CO/smoke alarm immediately outside bedrooms -Light in front bedroom not working -Provide AFCI protection for all outlets required per NEC 210.12. All outlets (definition: receptacle, light, utilization equipments, etc) shall be afci-protected unless located in following areas: outdoor, fire alarm outlet, underfloor space, unfinished basement, garage, bathroom, and attic. -Label or identify all dedicated non-gfci receptacles in garage and basement
Occupancy Inspection - Codes Residential Failed 5/25/2023 5/25/2023 05/25/2023
Misc
Corrective Action Required
05/23/2023
-Secure AC whip within 12” of disconnect -Provide security strike plate that comes with this door. Screw the exterior door embedded jamb brace into studs -Provide AFCI protection for all outlets required per NEC 210.12. Breakers 5,9,11,13,18,24 -Label or identify all dedicated non-gfci receptacles in garage and basement
Occupancy Inspection - Codes Residential Ready for Temp CO 5/26/2023 5/26/2023 05/26/2023
Misc
Corrective Action Required
05/25/2023
-Final grade, sod, splash blocks -Provide security strike plate that comes with this door. Screw the exterior door embedded jamb brace into studs
Erosion Control Inspection Residential Passed 06/08/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/23/2023
-PROVIDE MIN 3/4" & 6" DEEP OF GRAVEL AT LOT ENTRANCE. -RESTORE EROSION CONTROL ALONG THE STREET. REPLACE FLAT WATTLE EROSION CONTROL THAT HAS BEEN DRIVEN OVER NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Full C of O 6/8/2023 6/8/2023 06/08/2023
Misc
Resolved
06/08/2023
-Final grade, sod, splash blocks -Provide security strike plate that comes with this door. Screw the exterior door embedded jamb brace into studs
Documents & Images
Date Uploaded File Type Document Name
03/31/2022 Lot 303 PR Permit App
04/04/2022 Permit Codes Residential Plan Review
04/04/2022 Approved Plans Approved Drawings
04/04/2022 Plot Plan Approved Plot Plan
04/04/2022 Permit Codes Residential Plan Review
04/04/2022 Permit DS Building Permit
04/04/2022 Receipt Receipt for transaction:2022-001843
05/18/2022 Letter INSPECTION SUMMARY
06/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
10/14/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
11/10/2022 Letter INSPECTION SUMMARY
11/23/2022 Letter INSPECTION SUMMARY
11/23/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
12/05/2022 Letter INSPECTION SUMMARY
12/05/2022 Letter INSPECTION SUMMARY
12/16/2022 Letter INSPECTION SUMMARY
12/29/2022 Letter INSPECTION SUMMARY
04/10/2023 Letter INSPECTION SUMMARY
04/10/2023 Letter INSPECTION SUMMARY
05/23/2023 Letter INSPECTION SUMMARY
05/25/2023 Letter INSPECTION SUMMARY
05/31/2023 Certificate/License Codes Temporary Certificate of Occupancy
05/31/2023 Receipt Receipt for transaction:2023-003778
06/08/2023 Letter INSPECTION SUMMARY
06/08/2023 Letter Field Certificate of Occupancy
06/08/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home