Permit Application Status

PRRES20221108


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20221108
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - SUSPENDED SLAB - COVERED DECK
03/24/2022
04/01/2022
01/25/2024
Locations
Contacts
WOOD BROTHERS CONSTRUCTION INC, Address:PO BOX 553, Phone:(816) 564-5024  
Wood Brothers Construction INC, Address:PO Box 553  
WOODBROTHERSINC@GMAIL.COM  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
BMW ELECTRIC CO, Address:1238 W 31ST, Phone:(816) 289-3474  
PREFERRED PLUMBING INC, Address:1664 NW 415TH RD, Phone:(816) 828-1680  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $690.00 $690.00 Paid 04/01/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 04/01/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 04/01/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 04/01/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 04/01/2022
9110078-Valuation Fee New Single Family $1,970.11 $1,970.11 Paid 04/01/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/04/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 06/07/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Not Ready 6/16/2022 6/16/2022 06/16/2022
Misc
Corrective Action Required
06/16/2022
Inspection denied -no address posted
Erosion Control Inspection Residential Failed 6/22/2022 06/16/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/16/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Repair downed silt fence
Footing Inspection - Residential Passed 6/23/2022 06/23/2022
Misc
Informational
06/23/2022
Third party inspection performed
Underslab Plumbing Inspection - Residential Passed 6/23/2022 6/23/2022 06/23/2022
Misc
Corrective Action Required
06/16/2022
Inspection denied -no address posted
Sewer Service Inspection - R Passed 10/5/2022 10/05/2022
Water Service Inspection - R Passed 10/10/2022 (1:00) 10/10/2022 10/10/2022
Electrical Service Inspection Failed 1/3/2023 1/3/2023 01/03/2023
Misc
Corrective Action Required
01/03/2023
Remove sub-panel bonding screw
Gas Service Inspection - Residential Failed 1/3/2023 1/3/2023 01/03/2023
Misc
Corrective Action Required
01/03/2023
Bond gas line
All Rough Inspection - Residential Failed 1/4/2023 1/4/2023 01/04/2023
Misc
Corrective Action Required
01/04/2023
-address over notched stud at NE garage corner -fire block plumbing chase in garage to ceiling space -address holes in joist above mud room for dwv and pex closer than 2” to one another -fire block plumbing chase in kitchen to ceiling space -fire block pantry W wall to ceiling space -fire block kitchen hood wall to ceiling space -fire block fireplace wall to ceiling space -missing stud master closet/entry -fire block master bedroom walls to ceiling space -missing hanger above master bedroom -strap top plate breaks mast bedroom S wall -address holes drilled closer than 2” to one another above master bath for electrical -address over notched rafters above bed 4 provide engineering for fix -address exterior wall studs notched for anchor bolts -all anchor bolts to be in the middle 1/3 of sill plate -fire block vertically to horizontally every 10’ in basement -fire block S basement wall space to ceiling space -fire block bed 5 closet wall space to ceiling space -provide supports for furr downs to furr downs above -fire block beam ends in basement hall
All Rough Inspection - Residential Failed 1/10/2023 1/10/2023 01/10/2023
Misc
Corrective Action Required
01/04/2023
-fire block plumbing chase in garage to ceiling space -address holes in joist above mud room for dwv and pex closer than 2” to one another -fire block plumbing chase in kitchen to ceiling space -fire block master bedroom walls to ceiling space (see NE and SE corner) -address holes drilled closer than 2” to one another above master bath for electrical (provide engineering for fix) -address over notched rafters above bed 4 provide engineering for fix -address exterior wall studs notched for anchor bolts (not done) -fire block vertically to horizontally every 10’ in basement (seal penetrations) -fire block S basement wall space to ceiling space -fire block bed 5 closet and bath wall space to ceiling space -provide supports for furr downs to floor joists above
Electrical Service Inspection Passed 1/10/2023 1/10/2023 01/10/2023
Misc
Resolved
01/10/2023
Remove sub-panel bonding screw
Gas Service Inspection - Residential Passed 1/10/2023 1/10/2023 01/10/2023
Misc
Resolved
01/10/2023
Bond gas line
All Rough Inspection - Residential Failed 1/20/2023 1/20/2023 01/20/2023
Misc
Corrective Action Required
01/10/2023
-address holes in joist above mud room for dwv and pex closer than 2” to one another -address holes drilled closer than 2” to one another above master bath for electrical (provide engineering for fix) -address over notched rafters above bed 4 provide engineering for fix -address exterior wall studs notched for anchor bolts (not done) -fire block S basement wall space to ceiling space -fire block bed 5 closet and bath wall space to ceiling space OKAY TO INSULATE
All Rough Inspection - Residential Passed 2/2/2023 2/2/2023 02/02/2023
Misc
Resolved
02/02/2023
-address holes in joist above mud room for dwv and pex closer than 2” to o -address holes drilled closer than 2” to one another above master bath for electrical (provide engineering for fix) -address over notched rafters above bed 4 provide engineering for fix -address exterior wall studs notched for anchor bolts (not done) -fire block S basement wall space to ceiling space -fire block bed 5 closet and bath wall space to ceiling space OKAY TO INSULATE
Driveway Inspection Partial 4/27/2023 4/27/2023 04/27/2023
Misc
Informational
04/27/2023
4-27-23 RH. Driveway is formed up and aggreagate is placed and compacted.
Sidewalk Inspection Partial 5/1/2023 5/1/2023 05/01/2023
Misc
Informational
05/01/2023
5-1-23 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour.
Driveway Inspection Passed 5/4/2023 5/4/2023 05/04/2023
Misc
Informational
04/27/2023
4-27-23 RH. Driveway is formed up and aggreagate is placed and compacted. 5-4-23 RH. Driveway meets LS and ADA specifciation.
Sidewalk Inspection Passed 5/24/2023 5/24/2023 05/24/2023
Misc
Informational
05/01/2023
5-1-23 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour. 5-24-23 RH. Sidewalk meets LS and ADA specification.
Occupancy Inspection - Codes Residential Failed 6/6/2023 6/6/2023 06/06/2023
Misc
Corrective Action Required
06/06/2023
-open ground on outlets in garage -stairs in garage require graspable handrail to code -open electrical box above basement -landing at bottom of stairs at deck must be 36” in the direction of travel -2 1/2” through bolts at each deck post to beam connection -uncover covered manhole
Occupancy Inspection - Codes Residential Ready for Temp CO 6/7/2023 6/7/2023 06/07/2023
Misc
Corrective Action Required
06/06/2023
-final grade -sod -splash blocks and sump pump discharge to extend 36” from foundation -landing at bottom of stairs at deck must be 36” in the direction of travel -2 1/2” through bolts at each deck post to beam connection -uncover covered manhole
Piers/Caissons Inspection - Residential Passed 6/29/2023 06/29/2023
Plot Plan Inspection Passed 6/29/2023 06/29/2023
Erosion Control Inspection Residential Passed 6/29/2023 06/29/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/29/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Repair downed silt fence
Occupancy Inspection - Codes Residential Failed 6/29/2023 6/29/2023 06/29/2023
Misc
Corrective Action Required
06/07/2023
-landing at bottom of stairs at deck must be 36” in the direction of travel (R311.7.6) -2 1/2” through bolts at each deck post to beam connection (R507.5.1)
Occupancy Inspection - Codes Residential Failed 7/10/2023 7/10/2023 07/10/2023
Misc
Corrective Action Required
06/29/2023
TCO expiered 7/7/23 Submit TCO extension request form -landing at bottom of stairs at deck must be 36” in the direction of travel (R311.7.6) -2 1/2” through bolts at each deck post to beam connection (R507.5.1)
Occupancy Inspection - Codes Residential Failed 11/28/2023 11/28/2023 11/28/2023
Misc
Partial Correction
11/28/2023
TCO expiered 7/7/23 Submit TCO extension request form -2 1/2” through bolts at each deck post to beam connection (R507.5.1) PROVIDE DOCUMENTATION THAT LEDGER LOCKS MEET THE CODE REQUIREMENT
Occupancy Inspection - Codes Residential Full C of O 1/25/2024 1/25/2024 01/25/2024
Misc
Resolved
01/25/2024
Documents & Images
Date Uploaded File Type Document Name
03/24/2022 License_Tax_Application
03/24/2022 Permit Codes Residential Plan Review
04/01/2022 Approved Plans APPROVED PLANS
04/01/2022 Plot Plan APPROVED PLOT PLAN
04/01/2022 Permit Codes Residential Plan Review
04/01/2022 Permit DS Building Permit
04/01/2022 Receipt Receipt for transaction:2022-001822
04/27/2022 Plans pier plan detail
05/06/2022 M L Crose 3104 SW Summit View Trl LSMO SVF Lot 93 Wood Bros P 2022-1108 3rd Party Footing Inspection Report 5-6-22
06/16/2022 Letter INSPECTION SUMMARY
06/16/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
10/05/2022 Letter INSPECTION SUMMARY
10/10/2022 Letter INSPECTION SUMMARY
01/03/2023 Letter INSPECTION SUMMARY
01/03/2023 Letter INSPECTION SUMMARY
01/04/2023 Receipt Receipt for transaction:2023-000035
01/04/2023 Letter INSPECTION SUMMARY
01/10/2023 Letter INSPECTION SUMMARY
01/10/2023 Letter INSPECTION SUMMARY
01/10/2023 Letter INSPECTION SUMMARY
01/20/2023 Letter INSPECTION SUMMARY
02/01/2023 Final_2023_01_31_Struct_LSMO_Woods Brothers Construction
02/01/2023 MISSOURI Rev Final_2023_01_31_Struct_LSMO_Woods Brothers Construction
02/02/2023 Letter INSPECTION SUMMARY
04/27/2023 Letter INSPECTION SUMMARY
05/01/2023 Letter INSPECTION SUMMARY
05/04/2023 Letter INSPECTION SUMMARY
05/24/2023 Letter INSPECTION SUMMARY
06/06/2023 Letter INSPECTION SUMMARY
06/06/2023 DW PIER INSPECTION LETTER Durango 2 Lot 93 SVF 3104 SW Summit View Trail (1)
06/07/2023 Certificate/License Codes Temporary Certificate of Occupancy
06/07/2023 Receipt Receipt for transaction:2023-004036
06/29/2023 Letter INSPECTION SUMMARY
06/29/2023 Letter INSPECTION SUMMARY
06/29/2023 Letter INSPECTION SUMMARY
06/29/2023 Letter INSPECTION SUMMARY
07/10/2023 Letter INSPECTION SUMMARY
11/27/2023 Letter Codes 10 Day Letter
11/28/2023 Letter INSPECTION SUMMARY
01/25/2024 Letter Field Certificate of Occupancy
01/25/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home