Permit Application Status

PRRES20220635


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220635
Building Permit - Residential
Certificate of Occupancy
ACH DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. COVERED DECK.
02/22/2022
03/14/2022
08/23/2022
04/03/2023
Locations
Contacts
CAPITAL CONSTRUCTION SERVICES LLC, Address:2642 NE HAGAN RD, Phone:(816) 875-0018  
ACH DEVELOPMENT LLC, Address:3170 NE CARNEGIE DR STE 400  
Doug Rothfuss, Address:2642 HAGAN RD  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INHOME SYSTEMS LLC, Address:510 MISSION RD SW, Phone:(816) 372-0483  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
DROTHFUSS@CAPITALCONST.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $570.00 $570.00 Paid 03/14/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 03/14/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 03/14/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 03/14/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/14/2022
9110078-Valuation Fee New Single Family $1,354.56 $1,354.56 Paid 03/14/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/09/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/17/2022 (11:00) 3/17/2022 03/17/2022
Underslab Plumbing Inspection - Residential Failed 4/1/2022 04/01/2022
Misc
Corrective Action Required
04/01/2022
-NOT READY. BACKFILL TO F. WALL FOR FULL VISUAL ACCESS
Underslab Plumbing Inspection - Residential Passed 4/12/2022 4/12/2022 04/12/2022
Misc
Resolved
04/12/2022
-NOT READY. BACKFILL TO F. WALL FOR FULL VISUAL ACCESS
Sewer Service Inspection - R Passed 4/25/2022 (9:45) 4/25/2022 04/25/2022
Water Service Inspection - R Passed 4/27/2022 (1:30) 4/27/2022 04/27/2022
Piers/Caissons Inspection - Residential Passed 6/23/2022 (2:00) 6/23/2022 06/23/2022
Erosion Control Inspection Residential Failed 6/23/2022 06/23/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/23/2022
DEFICIENT EROSION CONTROL INSTALLATION ALONG THE STREET. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Electrical Service Inspection Passed 7/28/2022 7/28/2022 07/28/2022
Gas Service Inspection - Residential Failed 7/28/2022 7/28/2022 07/28/2022
Misc
Corrective Action Required
07/28/2022
-Pressure less than ten psi
All Rough Inspection - Residential Failed 7/28/2022 7/28/2022 07/28/2022
Misc
Corrective Action Required
07/28/2022
-Install collar ties near roof ridge above garage -Fb garage duct chase from soffit; Fb all wall plate penetrations -Pan off return air space from unused joist space above living room TV wall -Seal penetrations of ceiling return air space -Protect wiring at bottom wall plate near fireplace; near rear exterior door; -Provide a receptacle within 18” of wall at rear dining area -Complete soffit above kitchen countertop and Fb as required -Fb front office window wall from joist space -Install header support for ridge beam above bedroom 4 window -Support upper end of hip rafter to beam above bedroom 3 -Install collar ties @4 ft interval at upper roof ridge -Fb dead space adjacent to Jack-Jill bathroom tub -Replace damaged NM cable above Jack-Jill bathroom switch -Install roof flashing at dryer duct roof penetration -Support valley rafter to 2x10 header above master bathroom -Provide min 12”x12” of clear access opening to hydro tub pump. -Fb master bedroom/bathroom wall, rear master bedroom, and duct chase from roof -Provide purlin support every 4 ft or less -Support mid-stair landing header joist -Over notched joist below half bathroom -Toe nail joists to sill plates per code -Support joists with hangers at basement opening into garage duct chase **DO NOT INSULATE
Gas Service Inspection - Residential Passed 7/29/2022 7/29/2022 07/29/2022
Misc
Resolved
07/29/2022
-Pressure less than ten psi
All Rough Inspection - Residential Failed 7/29/2022 7/29/2022 07/29/2022
Misc
Corrective Action Required
07/28/2022
-Install collar ties near roof ridge above garage -Fb garage duct chase from soffit; -Install roof flashing at dryer duct roof penetration -Provide min 12”x12” of clear access opening to hydro tub pump. -Provide purlin support every 4 ft or less -Over notched joist below half bathroom **OK TO INSULATE
All Rough Inspection - Residential Failed 8/5/2022 8/5/2022 08/05/2022
Misc
Corrective Action Required
07/29/2022
-Install collar ties near roof ridge above garage -Fb garage duct chase from soffit; -Install roof flashing at dryer duct roof penetration -Provide min 12”x12” of clear access opening to hydro tub pump. -Provide purlin support every 4 ft or less -Over notched joist below half bathroom **OK TO INSULATE
Misc
Corrective Action Required
08/05/2022
inspection denied no address posted. Mitchell Schwarz 08/05/2022 10:15 AM
All Rough Inspection - Residential Passed 8/8/2022 8/8/2022 08/08/2022
Misc
Resolved
08/08/2022
Misc
Resolved
08/08/2022
Driveway Inspection Partial 8/12/2022 8/12/2022 08/15/2022
Misc
Informational
08/15/2022
8-15-22 AN forms are in place and aggregate is present and compacted
Driveway Inspection Passed 8/17/2022 8/17/2022 08/17/2022
Misc
Informational
08/15/2022
8-15-22 AN forms are in place and aggregate is present and compacted 8-17-22 AN driveway looks good and meets Ada spec
Sidewalk Inspection Partial 9/19/2022 9/19/2022 09/19/2022
Sidewalk Inspection Partial 9/21/2022 09/22/2022
Misc
Informational
09/22/2022
Sidewalk was formed and rock was compacted.
Sidewalk Inspection Passed 9/22/2022 09/22/2022
Misc
Informational
09/22/2022
Sidewalk was formed and rock was compacted.
Misc
Informational
09/22/2022
Concrete has been poured and appears to be compliant.
Erosion Control Inspection Residential Passed 03/07/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/07/2023
DEFICIENT EROSION CONTROL INSTALLATION ALONG THE STREET. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 3/7/2023 3/7/2023 03/07/2023
Misc
Corrective Action Required
03/07/2023
-Sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Secure AC whip within 12” of disconnect; install missing cover; connect whip to connector -Install tamper-proof caps at AC valves -Provide sewer tracer wire port at grade -Anchor column to floor
Occupancy Inspection - Codes Residential Ready for Temp CO 3/9/2023 3/9/2023 03/09/2023
Misc
Corrective Action Required
03/07/2023
-Sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc
Occupancy Inspection - Codes Residential Full C of O 4/3/2023 4/3/2023 04/03/2023
Misc
Resolved
04/03/2023
-Sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc
Documents & Images
Date Uploaded File Type Document Name
02/22/2022 Lot 299 - Application
02/24/2022 Permit Codes Residential Plan Review
03/01/2022 Plot Plan APPROVED PLOT PLAN
03/01/2022 Drawing APPROVED DRAWINGS
03/01/2022 Permit Codes Residential Plan Review
03/14/2022 Permit DS Building Permit
03/14/2022 Receipt Receipt for transaction:2022-001369
03/17/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter INSPECTION SUMMARY
04/27/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/28/2022 Letter INSPECTION SUMMARY
07/28/2022 Letter INSPECTION SUMMARY
07/28/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
08/05/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
08/15/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
09/19/2022 Letter INSPECTION SUMMARY
09/22/2022 Letter INSPECTION SUMMARY
09/22/2022 Letter INSPECTION SUMMARY
03/07/2023 Letter INSPECTION SUMMARY
03/07/2023 Letter INSPECTION SUMMARY
03/07/2023 Letter INSPECTION SUMMARY
03/07/2023 Letter INSPECTION SUMMARY
03/09/2023 Certificate/License Codes Temporary Certificate of Occupancy
03/09/2023 Receipt Receipt for transaction:2023-001317
04/03/2023 Letter Field Certificate of Occupancy
04/03/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home