Summary
PRRES20220582
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 05/23/2022 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 11/16/2022 12:00 AM by username 'Mitchell Schwarz'.
02/16/2022
03/02/2022
08/21/2022
05/02/2023
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
WALKERCUSTOMHOMESKC@GMAIL.COM  
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $420.00 $420.00 Paid 03/02/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 03/02/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 03/02/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 03/02/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 03/02/2022
9110078-Valuation Fee New Single Family $1,160.29 $1,160.29 Paid 03/02/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 5/11/2022 05/11/2022
Footing Inspection - Residential Passed 5/11/2022 05/11/2022
Misc
Informational
05/11/2022
Third party inspection performed
Water Service Inspection - R Passed 5/17/2022 (10:00) 5/17/2022 05/17/2022
Erosion Control Inspection Residential Failed 5/18/2022 05/18/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/18/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 05/18/2022 9:51 AM
Underslab Plumbing Inspection - Residential Passed 5/18/2022 5/18/2022 05/18/2022
Erosion Control Inspection Residential Failed - Stop Work 5/23/2022 05/23/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/18/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 05/18/2022 9:51 AM
Misc
Corrective Action Required
05/23/2022
Erosion control still not in compliance 05/23/22
Erosion Control Inspection Residential Passed 11/16/2022 11/16/2022 11/16/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
11/16/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 05/18/2022 9:51 AM
Misc
Resolved
11/16/2022
Erosion control still not in compliance 05/23/22
All Rough Inspection - Residential Failed 11/18/2022 11/18/2022 11/18/2022
Misc
Corrective Action Required
11/18/2022
- Provide anchor bolts plate break single bay garage within 12” - PFH portal frame, header to jack stud strap R602.10.6.4 - Solid block joist above beam garage per plan - Strap top plate rear of single bay garage less than 24” over lap - Missing nails joist hangers at owner entry and laundry - Provide security blocking at all doors - Address rafters landing on double 2x10” at pantry entry - Fb sides of fire place dead space above first plate - Repair floor dining room - Complete Fb of ceiling height change at Great room and entry - Provide tempered glass at front door - Fb upward penetrations in bedroom 2 - Fb floor penetration bedroom 2 - Repair floor master closet - Fb upward penetration master closet - Fb floor master bathroom tub - Strap top plate master bedroom at triple 2x12s exterior wall less than 24” over lap - Nail all exterior corners - Secure gas line to fire place within 12” of appliance - Address rafters landing on blocks through out - Steel column at bottom of stairs plan calls for 3 1/2” (F) - Provide anchor bolt at plate break within 12” East wall - Provide anchor bolts bedroom 3 within 12” of plate breaks 3 locations
Electrical Service Inspection Failed 11/18/2022 11/18/2022 11/18/2022
Miscellaneous Correction
Corrective Action Required
11/18/2022
- if landing UFER bond to grounding bus provide #4 jumper to neutral bus both sides
Gas Service Inspection - Residential Failed 11/18/2022 11/18/2022 11/18/2022
Misc
Corrective Action Required
11/18/2022
- no pressure on gauge
Gas Service Inspection - Residential Failed 12/15/2022 12/15/2022 12/15/2022
Misc
Corrective Action Required
11/18/2022
- no pressure on gauge no change Shawn Hoffman 12/15/2022 8:01 AM
Electrical Service Inspection Passed 12/15/2022 12/15/2022 12/15/2022
Miscellaneous Correction
Resolved
12/15/2022
All Rough Inspection - Residential Failed 12/15/2022 12/15/2022 12/15/2022
Misc
Corrective Action Required
11/18/2022
- Strap top plate master bedroom at triple 2x12s exterior wall less than 24” over lap - Steel column at bottom of stairs plan calls for 3 1/2” (F)
All Rough Inspection - Residential Passed 12/21/2022 12/21/2022 12/21/2022
Misc
Resolved
12/21/2022
- Strap top plate master bedroom at triple 2x12s exterior wall less than 24” over lap - Steel column at bottom of stairs plan calls for 3 1/2” (F)
Gas Service Inspection - Residential Passed 12/21/2022 12/21/2022 12/21/2022
Misc
Resolved
12/21/2022
- no pressure on gauge no change Shawn Hoffman 12/15/2022 8:01 AM
Driveway Inspection Partial 3/20/2023 3/20/2023 03/20/2023
Misc
Informational
03/20/2023
3-20-23 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour.
Driveway Inspection Passed 3/27/2023 3/27/2023 03/27/2023
Misc
Informational
03/20/2023
3-20-23 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour. 3-27-23 RH. Driveway meets LS and ADA specification.
Piers/Caissons Inspection - Residential Passed 05/01/2023
Plot Plan Inspection Passed 05/01/2023
Occupancy Inspection - Codes Residential Failed 5/1/2023 5/1/2023 05/01/2023
Misc
Corrective Action Required
05/01/2023
-address non labeled breakers -label non GFCI outlet in unfinished area -provide access to sump pump area.
Occupancy Inspection - Codes Residential Full C of O 5/2/2023 5/2/2023 05/02/2023
Misc
Resolved
05/02/2023
-provide access to sump pump area.
Documents & Images
Date Uploaded File Type Document Name
02/16/2022 Lee's Summit City App Filled Out
02/22/2022 Permit Codes Residential Plan Review
03/01/2022 Approved Plans APPROVED PLANS
03/01/2022 Plot Plan APPROVED PLOT PLAN
03/01/2022 Permit Codes Residential Plan Review
03/02/2022 Permit DS Building Permit
03/02/2022 Receipt Receipt for transaction:2022-001106
04/08/2022 Wilmoth 2323 SW Serena Pl LSMO Summit View Farms Lot 79 Footing Inspection Report 4-6-22
05/11/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
05/18/2022 Letter INSPECTION SUMMARY
05/18/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter Stop Work Order
09/13/2022 Deck pier 3rd party inspection
11/18/2022 Letter INSPECTION SUMMARY
11/18/2022 Letter INSPECTION SUMMARY
11/18/2022 Letter INSPECTION SUMMARY
11/18/2022 Letter INSPECTION SUMMARY
11/18/2022 Letter INSPECTION SUMMARY
12/07/2022 2323 SW Serena Pl ROW
12/13/2022 SVF079 - Inspection Letter (12-6-22)
12/15/2022 Letter INSPECTION SUMMARY
12/15/2022 Letter INSPECTION SUMMARY
12/15/2022 Letter INSPECTION SUMMARY
12/21/2022 Letter INSPECTION SUMMARY
12/21/2022 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/27/2023 Letter INSPECTION SUMMARY
04/26/2023 LOT 79 ASBUILT
04/26/2023 Plot Plan approved as graded plot plan
05/01/2023 Letter INSPECTION SUMMARY
05/01/2023 Letter INSPECTION SUMMARY
05/01/2023 Letter INSPECTION SUMMARY
05/02/2023 Letter Field Certificate of Occupancy
05/02/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home