Summary
PRRES20220466
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - SUSPENDED SLAB - ENGINEERED FLOOR SYSTEM (DEF)
02/07/2022
03/02/2022
05/25/2023
Locations
Contacts
GALE HOMES II INC, Address:400 SW LONGVIEW BLVD, Unit 109, Phone:(816) 761-9292  
Matt Faulkner, Address:400 SW Longview BLVD, Unit:210  
MFAULKNER@GALECOMMUNITIES.COM  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
HATHEWAY ELECTRIC LLC, Address:3125 SW PRYOR RD, Phone:(660) 232-2419  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $840.00 $840.00 Paid 03/02/2022
Right of Way Permit Fee $85.00 $85.00 Paid 03/02/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 03/02/2022
Valuation Fee New Single Family $2,573.10 $2,573.10 Paid 03/02/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 03/02/2022
Water Meter Fee $479.24 $479.24 Paid 03/02/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Residential Passed 4/22/2022 04/12/2022
Footing Inspection - Residential Passed 4/12/2022 (9:00) 4/12/2022 04/12/2022
Erosion Control Inspection Residential Failed 4/22/2022 04/22/2022
Misc
Corrective Action Required
04/22/2022
Provide gravel filter
Sewer Service Inspection - R Passed 4/29/2022 04/29/2022
Water Service Inspection - R Partial 4/29/2022 04/29/2022
Misc
Corrective Action Required
04/29/2022
Partial, poly from foundation out. Tap not complete
Water Service Inspection - R Passed 5/2/2022 (11:00) 5/2/2022 05/02/2022
Misc
Corrective Action Required
04/29/2022
Partial, poly from foundation out. Tap not complete
Underslab Plumbing Inspection - Residential Passed 5/13/2022 5/13/2022 05/13/2022
Erosion Control Inspection Residential Failed 9/30/2022 09/30/2022
Misc
Resolved
09/30/2022
Provide gravel filter
Misc
Corrective Action Required
09/30/2022
PROVIVE SILT FENCE OR STAW SWADDLES AT FRONT OF LOT.
All Rough Inspection - Residential Failed 10/27/2022 10/27/2022 10/27/2022
Misc
Corrective Action Required
10/27/2022
- Anchor bolts middle third of plate north garage - I-beam in North garage to have 6 studs each side - PFH portal frame straps should include top plate ( both garages ) - Fire block I-beam garage to mud room - Fire block I-beam garage to pantry - Address LVL hip rafter notched south west corner dining room - Unable to inspect deck roof, open lid - Install fire place deck - Gas line to deck fire place must have shut off before gas inspection - Fire block top plate chase and double wall next to fire place - Provide joist hangers on.LVLS above double non load bearing wall - Fire block above fire place at top plate blocking fur out - Address both hip rafters over notched - In master bedroom - Add second stud under heder master bathroom at closet - Tighten through bolts on all I- beams fired out - Fire block attic space to mechanical room second floor - Add triple stud shoe on over bored studs loft - Support ridge north charlottes room - Security blocking at both basement man doors - Fire block fur out wall west side And check all fur downs - Tighten anchor bolts in basement - Fire block north exercise closet top plate - Fire block stud space between steel columns into fur down at landing - Fire block top plate basement laundry -
Gas Service Inspection - Residential Failed 10/27/2022 10/27/2022 10/27/2022
Miscellaneous Correction
Corrective Action Required
10/27/2022
Install deck fire place or add shut off valve at the location
Electrical Service Inspection Passed 10/27/2022 10/27/2022 10/27/2022
Gas Service Inspection - Residential Passed 11/10/2022 11/10/2022 11/10/2022
Miscellaneous Correction
Resolved
11/10/2022
Install deck fire place or add shut off valve at the location
All Rough Inspection - Residential Failed 11/10/2022 11/10/2022 11/10/2022
Misc
Corrective Action Required
10/27/2022
- Install fire place deck-secure ward flex - Provide joist hangers on.LVLS above double non load bearing wall-Use proper hangers - Address both hip rafters over notched In master bedroom-Complete per engineer's letter and remove insulation for inspection - Support ridge north charlottes room-Support hip rafters at same location - Fire block fur out wall west side And check all fur downs-fire block fur down at fur out wall west bed **OK TO INSULATE-DO NOT COVER INSPECTION ITEMS
All Rough Inspection - Residential Failed 11/14/2022 11/14/2022 11/14/2022
Misc
Corrective Action Required
11/10/2022
-UPLOAD ENGINEERS LETER ON MASTER BEDROOM LVL'S REPAIR **OK TO INSULATE-DO NOT COVER INSPECTION ITEMS
Driveway Inspection Partial 3/27/2023 3/27/2023 03/27/2023
Misc
Informational
03/27/2023
3-27-23 DP. Crew had DW formed, aggregate compacted. approved to pour. The road does need to be cleaned up from concrete truck tracking down Winter Road.
Driveway Inspection Passed 4/3/2023 4/3/2023 04/03/2023
Misc
Informational
03/27/2023
3-27-23 DP. Crew had DW formed, aggregate compacted. approved to pour. The road does need to be cleaned up from concrete truck tracking down Winter Road. 4-3-23 DP. DW was poured, forms removed, debris cleaned up. Passed.
Erosion Control Inspection Residential Failed 5/19/2023 05/19/2023
Misc
Corrective Action Required
09/30/2022
PROVIVE SILT FENCE OR STAW SWADDLES AT FRONT OF LOT.
All Rough Inspection - Residential Failed 05/19/2023
Misc
Corrective Action Required
11/14/2022
-UPLOAD ENGINEERS LETER ON MASTER BEDROOM LVL'S REPAIR **Reminded builder today: Shawn Hoffman 05/19/2023 11:09 AM
Occupancy Inspection - Codes Residential Failed 5/19/2023 5/19/2023 05/19/2023
Misc
Corrective Action Required
05/19/2023
- Provide hardware for front patio door - Provide security screws at all exterior doors - Secure whip at water heater second floor mechanical room - Provide protection from fall at second floor bedroom bench windows - Provide smoke detector in charlotte’s room - Basement island outlets not GFCI protected - GFCI outlet on wall counter of bar will not reset - Outlet at basement laundry not GFCI protected - Protect I-joist in basement, only 80 sq. Ft. Exception - Missing nails in joist hangers under deck - Protect I-joist above sump pump - Final grading and sod
Erosion Control Inspection Residential Passed 5/25/2023 05/25/2023
Misc
Resolved
05/25/2023
PROVIVE SILT FENCE OR STAW SWADDLES AT FRONT OF LOT.
All Rough Inspection - Residential Passed 5/25/2023 05/25/2023
Misc
Resolved
05/25/2023
-UPLOAD ENGINEERS LETER ON MASTER BEDROOM LVL'S REPAIR **Reminded builder today: Shawn Hoffman 05/19/2023 11:09 AM
Plot Plan Inspection Passed 5/25/2023 05/25/2023
Misc
Informational
05/25/2023
Plot plan has change, up to date on pool permit.
Occupancy Inspection - Codes Residential Full C of O 5/25/2023 5/25/2023 05/25/2023
Misc
Resolved
05/25/2023
Documents & Images
Date Uploaded File Type Document Name
02/09/2022 Application Form APPLICATION
02/09/2022 Application Form License Tax Form
03/02/2022 Approved Plans APPROVED PLANS
03/02/2022 Plot Plan APPROVED PLOT PLAN
03/02/2022 Permit Codes Residential Plan Review
03/02/2022 Permit DS Building Permit
03/02/2022 Receipt Receipt for transaction:2022-001103
03/17/2022 Final_2022_01_12_HPier_LSMO_Gale Homes
04/11/2022 Final_2022_03_14_SiteObv PierDes_LSMO_Gale Homes II
04/12/2022 Final_2022_03_28_HPier_LSMO_Gale Homes
04/12/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
05/02/2022 Letter INSPECTION SUMMARY
05/13/2022 Letter INSPECTION SUMMARY
09/30/2022 Letter Codes 140 Day Letter
10/27/2022 Letter INSPECTION SUMMARY
10/27/2022 Letter INSPECTION SUMMARY
10/27/2022 Letter INSPECTION SUMMARY
10/27/2022 Letter INSPECTION SUMMARY
11/10/2022 Letter INSPECTION SUMMARY
11/10/2022 Letter INSPECTION SUMMARY
11/14/2022 Letter INSPECTION SUMMARY
03/27/2023 Letter INSPECTION SUMMARY
04/03/2023 Letter INSPECTION SUMMARY
05/19/2023 Letter INSPECTION SUMMARY
05/19/2023 Letter INSPECTION SUMMARY
05/19/2023 Letter INSPECTION SUMMARY
05/25/2023 DW FRAMING INSPECTION RESPONSE Skelsey Residence 11-7-22
05/25/2023 Letter Codes Final Certificate of Occupancy
05/25/2023 Letter Field Certificate of Occupancy
05/25/2023 Letter INSPECTION SUMMARY
05/25/2023 Letter INSPECTION SUMMARY
05/25/2023 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home