Permit Application Status

PRRES20220126


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220126
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 08/23/2023 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 11/08/2023 12:00 AM by username 'Mitchell Schwarz'.
01/11/2022
01/11/2022
03/04/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
LOREN@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,003.24 $1,003.24 Paid 01/11/2022
Right of Way Permit Fee $85.00 $85.00 Paid 01/11/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/11/2022
8331507-Sewer Connection Fee $390.00 $390.00 Paid 01/11/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 01/11/2022
Water Meter Fee $479.24 $479.24 Paid 01/11/2022
Not Ready Inspection Fee $75.00 $75.00 Paid 11/09/2023
Not Ready Inspection Fee $75.00 $75.00 Paid 11/15/2023
Not Ready Inspection Fee $75.00 $75.00 Paid 11/22/2023
3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 02/29/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Residential Passed 6/22/2023 06/22/2023
Footing Inspection - Residential Passed 6/22/2023 (11:30) 6/22/2023 06/22/2023
Misc
Corrective Action Required
06/22/2023
Deck pier poured with footing
Underslab Plumbing Inspection - Residential Passed 7/10/2023 7/10/2023 07/10/2023
Sewer Service Inspection - R Passed 7/28/2023 (11:15) 7/28/2023 07/28/2023
Water Service Inspection - R Partial 7/28/2023 07/28/2023
Misc
Corrective Action Required
07/28/2023
Partial, pex out on foundation
Water Service Inspection - R Passed 8/1/2023 (8:30) 8/1/2023 08/01/2023
Misc
Resolved
08/01/2023
Partial, pex out on foundation
Erosion Control Inspection Residential Failed 8/18/2023 08/18/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/18/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed - Stop Work 8/23/2023 8/23/2023 08/23/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/18/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
08/23/2023
Erosion control still not in compliance Stop work issued -missing silt fence Mitchell Schwarz 8/23/23 1:12PM
Erosion Control Inspection Residential Not Ready 11/6/2023 11/6/2023 11/06/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/23/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
08/23/2023
Erosion control still not in compliance Stop work issued Mitchell Schwarz 8/23/23 1:12PM Gravel filter still not in compliance Mitchell Schwarz 11/06/23 10:25Am
Erosion Control Inspection Residential Partial 11/8/2023 11/08/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
11/08/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Resolved
11/08/2023
Erosion control still not in compliance Stop work issued Mitchell Schwarz 8/23/23 1:12PM Gravel filter still not in compliance Mitchell Schwarz 11/06/23 10:25Am
Misc
Informational
11/08/2023
Erosion control back in compliance at time of inspection. Mitchell Schwarz 11/8/23 9:36Am
Gas Service Inspection - Residential Failed 11/9/2023 11/9/2023 11/09/2023
Misc
Corrective Action Required
11/09/2023
Complete gas line installation at fireplace
Electrical Service Inspection Passed 11/9/2023 11/9/2023 11/09/2023
All Rough Inspection - Residential Failed 11/9/2023 11/9/2023 11/09/2023
Misc
Corrective Action Required
11/09/2023
-plate break strapping to be installed on top or bottom of top plate throughout -lib bracing to be installed to code -fire block plumbing chase in garage -cs-pf exterior nailing at dining room -uncover covered deck trusses for inspection -missing lib bracing in n bed 1 -bath 1 toilet room bracing detail not identified on plans -complete gas line installation at fire place -4 2x4 under girder truss see stairwell wall and laundry -b3 truss missing lateral bracing. Check all other trusses -tighten anchor bolt in wet bar area -fireblock wall space to ceiling space at wet bar area and furr down -missing multiple areas throughout basement -address multiple studs over notched for anchor bolts in basement -fire blocking for wall space to ceiling space to be of approved fire blocking material -missing bracing for S rec room wall -missing solid blocking under kitchen island per plans -over drilled floor joist above bed 4 -over drilled and over notched floor joist above basement bath (2 joist) -
All Rough Inspection - Residential Not Ready 11/15/2023 11/15/2023 11/15/2023
Misc
Corrective Action Required
11/09/2023
-plate break strapping to be installed on top or bottom of top plate throughout -lib bracing to be installed to code -fire block plumbing chase in garage -cs-pf exterior nailing at dining room (bottom of cspf nailing incorrectly done) -missing lib bracing in n bed 1 -bath 1 toilet room bracing detail not identified on plans -complete gas line installation at fire place (not secured) -fireblock wall space to ceiling space at wet bar area and furr down (seal penetrations and gaps) -fireblock vertical floor to ceiling every 10’ in wall space missing multiple areas throughout basement. -address multiple studs over notched for anchor bolts in basement -missing bracing for S rec room wall (nail to design specifications) -over drilled floor joist above bed 4 -over drilled and over notched floor joist above basement bath (2 joist)
Gas Service Inspection - Residential Passed 11/15/2023 11/15/2023 11/15/2023
Misc
Resolved
11/15/2023
Complete gas line installation at fireplace
All Rough Inspection - Residential Failed 11/15/2023 11/15/2023 11/15/2023
Misc
Corrective Action Required
11/15/2023
-plate break strapping to be installed on top or bottom of top plate throughout -fire block plumbing chase in garage -cs-pf exterior nailing at dining room (bottom of cspf nailing incorrectly done) -missing lib bracing in n bed 1 -bath 1 toilet room bracing detail not identified on plans -complete gas line installation at fire place (not secured) -fireblock wall space to ceiling space at wet bar area and furr down (seal penetrations and gaps) -fireblock vertical floor to ceiling every 10’ in wall space missing multiple areas throughout basement. -address multiple studs over notched for anchor bolts in basement -missing bracing for S rec room wall (nail to design specifications) ensure exterior nailing as well -over drilled floor joist above bed 4 -over drilled and over notched floor joist above basement bath (2 joist)
All Rough Inspection - Residential Not Ready 11/17/2023 11/17/2023 11/17/2023
Misc
Corrective Action Required
11/15/2023
-fire block plumbing chase in garage -call in for inspection of gb bracing at bed 1 bath time of dry wall -secure gas line at fire place (still not secured) -fireblock wall space to ceiling space at wet bar area and furr down (seal penetrations and gaps see dwv, beams ends exc) -fireblock vertical floor to ceiling every 10’ in wall space missing multiple areas throughout basement. (SEAL GAPS AND PENETRATIONS throughout) (Multiple penetrations and gaps in fireblocking throughout) -over drilled floor joist above bed 4(provide engineering for fix) -over drilled and over notched floor joist above basement bath (2 joist)(provide engineering for fix)
All Rough Inspection - Residential Failed 11/22/2023 11/22/2023 11/22/2023
Misc
Corrective Action Required
11/17/2023
-call in for inspection of gb bracing at bed 1 bath time of dry wall -over drilled floor joist above bed 4(provide engineering for fix) -over drilled and over notched floor joist above basement bath (2 joist)(provide engineering for fix)
All Rough Inspection - Residential Failed 11/28/2023 11/28/2023 11/28/2023
Misc
Corrective Action Required
11/22/2023
-call in for inspection of gb bracing at bed 1 bath time of dry wall -over drilled floor joist above bed 4(provide engineering for fix) -over drilled and over notched floor joist above basement bath (2 joist)(provide engineering for fix) no access front door blocked shut garage doors locked gara
All Rough Inspection - Residential Failed 11/29/2023 11/29/2023 11/29/2023
Misc
Corrective Action Required
11/28/2023
-call in for inspection of gb bracing at bed 1 bath time of dry wall -over drilled and over notched floor joist above basement bath (2 joist)(FIX TO ENGINEER SPECIFICATIONS)
All Rough Inspection - Residential Failed 11/30/2023 11/30/2023 11/30/2023
Misc
Corrective Action Required
11/29/2023
-call in for inspection of gb bracing at bed 1 bath time of dry wall okay to insulate
All Rough Inspection - Residential Failed 12/5/2023 12/5/2023 12/05/2023
Misc
Corrective Action Required
11/30/2023
-call in for inspection of gb bracing at bed 1 bath time of dry wall(top and bottom plate not fastened to gb specifications ) okay to insulate
All Rough Inspection - Residential Passed 12/6/2023 12/6/2023 12/06/2023
Misc
Resolved
12/06/2023
-call in for inspection of gb bracing at bed 1 bath time of dry wall(top and bottom plate not fastened to gb specifications ) okay to insulate
Driveway Inspection Partial 12/14/2023 12/14/2023
Misc
Informational
12/14/2023
12-14-23 PS Driveway pre pour, forms in place and aggregate compacted, approved to pour
Driveway Inspection Passed 1/26/2024 1/26/2024 01/26/2024
Misc
Informational
12/14/2023
12-14-23 PS Driveway pre pour, forms in place and aggregate compacted, approved to pour 1-26-24 PS Driveway meets LS Specs
Erosion Control Inspection Residential Failed 2/7/2024 02/07/2024
Misc
Resolved
02/07/2024
Erosion control back in compliance at time of inspection. Mitchell Schwarz 11/8/23 9:36Am
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/07/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/07/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN EROSION CONTROL AT FRONT OF LOT. INTALL WHERE MISSING
Erosion Control Inspection Residential Passed 3/1/2024 03/01/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
03/01/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/01/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN EROSION CONTROL AT FRONT OF LOT. INTALL WHERE MISSING
Plot Plan Inspection Passed 3/1/2024 03/01/2024
Occupancy Inspection - Codes Residential Failed 3/1/2024 3/1/2024 03/01/2024
Misc
Corrective Action Required
03/01/2024
- Seal top of electrical meter and - Seal exterior penetrations ( gas line) - Seal top of AC disconnect
Occupancy Inspection - Codes Residential Full C of O 3/4/2024 3/4/2024 03/04/2024
Misc
Resolved
03/04/2024
- Seal top of electrical meter and - Seal exterior penetrations ( gas line) - Seal top of AC disconnect
Documents & Images
Date Uploaded File Type Document Name
01/11/2022 LOT 83 FINAL
01/11/2022 H3 #83 - PERMIT APP
01/11/2022 Approved Plans Approved Drawings
01/11/2022 Approved Plans Approved Truss Layout
01/11/2022 Approved Plans Approved Truss Package
01/11/2022 Plot Plan Approved Plot Plan
01/11/2022 Permit Codes Residential Plan Review
01/11/2022 Permit DS Building Permit
01/11/2022 Receipt Receipt for transaction:2022-000182
06/08/2022 Letter Codes 140 Day Letter
06/22/2023 Letter INSPECTION SUMMARY
07/10/2023 Letter INSPECTION SUMMARY
07/10/2023 Letter INSPECTION SUMMARY
07/10/2023 Letter INSPECTION SUMMARY
07/28/2023 Letter INSPECTION SUMMARY
07/28/2023 Letter INSPECTION SUMMARY
08/01/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/23/2023 Letter Stop Work Order
08/23/2023 Letter Stop Work Order
11/06/2023 Letter INSPECTION SUMMARY
11/08/2023 Letter INSPECTION SUMMARY
11/08/2023 Letter INSPECTION SUMMARY
11/09/2023 Letter INSPECTION SUMMARY
11/09/2023 Letter INSPECTION SUMMARY
11/09/2023 Letter INSPECTION SUMMARY
11/09/2023 Receipt Receipt for transaction:2023-008403
11/15/2023 Letter INSPECTION SUMMARY
11/15/2023 Letter INSPECTION SUMMARY
11/15/2023 Letter INSPECTION SUMMARY
11/15/2023 Receipt Receipt for transaction:2023-008545
11/16/2023 H3 #83 - SOMERSET - BRACING CLARIFICATION - 231114
11/22/2023 Letter INSPECTION SUMMARY
11/22/2023 83 Hawthorne Ridge Letter
11/22/2023 Receipt Receipt for transaction:2023-008701
11/28/2023 Letter INSPECTION SUMMARY
11/29/2023 Letter INSPECTION SUMMARY
11/30/2023 Letter INSPECTION SUMMARY
12/05/2023 Letter INSPECTION SUMMARY
12/05/2023 Letter INSPECTION SUMMARY
12/06/2023 Letter INSPECTION SUMMARY
12/14/2023 Letter INSPECTION SUMMARY
01/26/2024 Letter INSPECTION SUMMARY
02/07/2024 Letter INSPECTION SUMMARY
02/29/2024 Receipt Receipt for transaction:2024-001248
03/01/2024 Letter INSPECTION SUMMARY
03/01/2024 Letter INSPECTION SUMMARY
03/01/2024 Letter INSPECTION SUMMARY
03/04/2024 Letter Field Certificate of Occupancy
03/04/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home