Summary
PRRES20220006
Building Permit - Residential
Certificate of Occupancy
JCM DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - UNCOVERED DECK
01/03/2022
01/07/2022
07/03/2022
10/14/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
JCM DEVELOPMENT LLC, Address:1314 SW MARKET ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,034.72 $1,034.72 Paid 01/07/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/07/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/07/2022
8331507-Sewer Connection Fee $420.00 $420.00 Paid 01/07/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 01/07/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 01/07/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/25/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/15/2022 2/15/2022 02/15/2022
Misc
Informational
02/15/2022
APPROVED PER DAVID P AINSWORTH 1/26/22
Erosion Control Inspection Residential Partial 2/15/2022 2/15/2022 02/15/2022
Misc
Corrective Action Required
02/15/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Underslab Plumbing Inspection - Residential Failed 2/16/2022 2/16/2022 02/16/2022
Misc
Corrective Action Required
02/16/2022
WHERE BUILDING SEWER HAS CHANGE OF DIRECTION GREATER THAN 45 DEGREES A CLEANOUT SHALL BE INSTALLED AT THE CHANGE OF DIRECTION P3005.2.4
Erosion Control Inspection Residential Partial 2/16/2022 2/16/2022 02/16/2022
Misc
Corrective Action Required
02/15/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Underslab Plumbing Inspection - Residential Passed 3/1/2022 3/1/2022 03/01/2022
Misc
Resolved
03/01/2022
Sewer Service Inspection - R Passed 3/1/2022 (10:00) 3/1/2022 03/01/2022
Water Service Inspection - R Passed 3/8/2022 (9:45) 3/8/2022 03/08/2022
Erosion Control Inspection Residential Failed 3/8/2022 3/8/2022 03/08/2022
Misc
Resolved
03/08/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/08/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Erosion Control Inspection Residential Failed 5/11/2022 5/11/2022 05/11/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/11/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Miscellaneous Correction
Corrective Action Required
05/11/2022
MAINTAIN GRAVEL FILTER TO HOUSE
All Rough Inspection - Residential Failed 5/11/2022 5/11/2022 05/11/2022
Miscellaneous Correction
Corrective Action Required
05/11/2022
-Maintain gravel filter from street to house -Provide bonding jumpers at metallic boxes at garage -Tighten all anchor bolts -Anchor bolts to be in middle 3rd of plate-see by service panel and west garage wall -Nail corner and intersecting wall studs 12” oc throughout -Provide stud shoe on over bored stud at service panel -Missing truss hanger at D2 truss in double car bay -Provide (2) nails per framing member at LIB throughout -Address joist bored closer than 2” to bottom at nm in double car bay -Secure nm at range within 12” of box -Protect nm near owner’s entry less than 1.25” to face of framing -Address over bored joists at dwv at owner’s entry closet -Address holes bored closer than 2” in joists at owner’s entry -Provide structural strap at over bored top plate in powder room -Address Overbored joist in pantry -(3) 2x12 at stairwell/entry per plans -Protect nm by SGD less than 1.25” to face of stud -Sister damaged stud by beam at exterior great room wall -Protect nm at top plate by entry door -Strap top plates lapped less than 24” at second floor landing -Address exterior walls not connected where 2x6 and 2x4 walls meet stairwell/ walk in closet -Seal through floor penetration at master bath -Provide proper slope at vent in attic space at master bath -Provide proper slope at laundry drain -Seal gaps at fireblocking in hvac chase -Protect nm at laundry room to plate -Seal top plate penetration at exterior wall bed 3 -Provide (3) 2x6 stud pack to beam for stud pack above great room in basement-see plans -(2) 2x12 corner to corner at CS-PF in basement windows -Complete CSPF at basement windows-see details -Flash and install basement windows -Strap top plate lapped less than 24” at beam by windows -Tighten anchor bolts -Anchor bolts to be in middle 3rd of plate -No deck installed at this time
Electrical Service Inspection Passed 5/11/2022 5/11/2022 05/11/2022
Gas Service Inspection - Residential Passed 5/11/2022 5/11/2022 05/11/2022
Erosion Control Inspection Residential Failed 05/20/2022
Miscellaneous Correction
Corrective Action Required
05/11/2022
MAINTAIN GRAVEL FILTER TO HOUSE, SPREAD GRAVEL TO COVER AREAS NOT PROTECTED BY SILT FENCE
All Rough Inspection - Residential Not Ready 5/20/2022 5/20/2022 05/20/2022
Miscellaneous Correction
Corrective Action Required
05/11/2022
Maintain gravel filter from street to house -Provide bonding jumpers at metallic boxes at garage-NOT DONE -Provide stud shoe on over bored stud at service panel-FILL ALL HOLES WITH APPROVED NAILS -Address holes bored closer than 2” in joists at owner’s entry-NOT DONE -Address Overbored joist in pantry- STRAP UNDER THE HOLE -Strap top plates lapped less than 24” at second floor landing -Provide (3) 2x6 stud pack to beam for stud pack above great room in basement-see plans -(2) 2x12 corner to corner at CS-PF in basement windows -Complete CSPF at basement windows-see details -Flash and install basement windows -Strap top plate lapped less than 24” at beam by windows -Tighten anchor bolts -Anchor bolts to be in middle 3rd of plate -No deck installed at this time
All Rough Inspection - Residential Failed 6/2/2022 6/2/2022 06/02/2022
Miscellaneous Correction
Corrective Action Required
05/20/2022
-Flash and install basement windows **OK to insulate and rock**
Erosion Control Inspection Residential Partial 06/02/2022
Miscellaneous Correction
Resolved
06/02/2022
MAINTAIN GRAVEL FILTER TO HOUSE, SPREAD GRAVEL TO COVER AREAS NOT PROTECTED BY SILT FENCE
Driveway Inspection Passed 6/16/2022 6/16/2022 06/16/2022
Misc
Informational
06/16/2022
On Thursday, 6-16-2022 I performed and passed a driveway inspection for concrete placement.
All Rough Inspection - Residential Passed 7/19/2022 7/19/2022 07/19/2022
Miscellaneous Correction
Resolved
07/19/2022
-Flash and install basement windows **OK to insulate and rock**
Erosion Control Inspection Residential Partial 7/19/2022 7/19/2022 07/19/2022
Piers/Caissons Inspection - Residential Passed 8/18/2022 (8:15) 8/18/2022 08/18/2022
Plot Plan Inspection Passed 8/30/2022 08/30/2022
Erosion Control Inspection Residential Passed 9/22/2022 09/22/2022
Occupancy Inspection - Codes Residential Failed 9/22/2022 9/22/2022 09/22/2022
Misc
Corrective Action Required
09/22/2022
-seal all penetrations in siding, seal across top of AC disconnect and meter can -downspouts and sump pump min 36” discharge from foundation -(2) 1/2” through bolts each post/beam connection at deck -shear off set screw head anti siphon device basement on spigot -provide mid rail support at basement stairs handrail
Occupancy Inspection - Codes Residential Full C of O 10/14/2022 10/14/2022 10/14/2022
Misc
Resolved
10/14/2022
Documents & Images
Date Uploaded File Type Document Name
01/03/2022 CB #155 - PERMIT APPLICATION
01/03/2022 Approved Plans Approved Drawings
01/03/2022 Approved Plans Approved Truss Layout
01/03/2022 Approved Plans Approved Truss Package
01/04/2022 Permit Codes Residential Plan Review
01/06/2022 Plot Plan Approved Plot Plan
01/06/2022 Permit Codes Residential Plan Review
01/07/2022 Permit DS Building Permit
01/07/2022 Receipt Receipt for transaction:2022-000119
02/14/2022 M L Crose 3538 SE Corbin Dr LSMO Cobey Creek Lot 155 Clayton Permit 2022-0006 Footing Inspection Report 1-26-22
02/15/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/18/2022 155 COBEY CREEK LETTER #2
05/18/2022 155 COBEY CREEK LETTER
05/20/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
05/23/2022 155 COBEY CREEK LETTER #3
06/02/2022 Letter INSPECTION SUMMARY
06/02/2022 Letter INSPECTION SUMMARY
06/16/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
07/25/2022 Receipt Receipt for transaction:2022-006045
08/18/2022 Letter INSPECTION SUMMARY
08/29/2022 Plot Plan Approved As Graded Plot Plan
08/30/2022 Letter INSPECTION SUMMARY
09/22/2022 Letter INSPECTION SUMMARY
09/22/2022 Letter INSPECTION SUMMARY
10/14/2022 Letter Field Certificate of Occupancy
10/14/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home