Permit Application Status

PRRES20216303


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20216303
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINIHSED BASEMENT - COVERED PATIO
12/09/2021
12/10/2021
06/08/2022
04/19/2023
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $630.00 $630.00 Paid 12/10/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 12/10/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/10/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 12/10/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 12/10/2021
9110078-Valuation Fee New Single Family $1,662.16 $1,662.16 Paid 12/10/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/04/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 04/18/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/5/2022 (1:30) 4/5/2022 04/05/2022
Erosion Control Inspection Residential Failed 4/26/2022 04/26/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/26/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 04/26/2022 3:09 PM
Erosion Control Inspection Residential Failed 5/5/2022 05/05/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/26/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 04/26/2022 3:09 PM
DCM5 ESC INSP DENIED
Corrective Action Required
05/05/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Underslab Plumbing Inspection - Residential Not Ready 5/5/2022 5/5/2022 05/05/2022
Misc
Corrective Action Required
05/05/2022
inspection denied erosion control not in compliance
Erosion Control Inspection Residential Partial 5/11/2022 05/11/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
05/11/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 04/26/2022 3:09 PM
DCM5 ESC INSP DENIED
Resolved
05/11/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Misc
Informational
05/11/2022
Erosion control back in compliance at time of inspection. Mitchell Schwarz 05/11/2022 11:33 AM
Underslab Plumbing Inspection - Residential Passed 5/11/2022 5/11/2022 05/11/2022
Misc
Resolved
05/11/2022
inspection denied erosion control not in compliance
Water Service Inspection - R Partial 5/27/2022 (11:00) 5/27/2022 05/27/2022
Misc
Informational
05/27/2022
Water service ran to foundation must not though foundation wall.
Sewer Service Inspection - R Passed 6/3/2022 (8:00) 6/3/2022 06/02/2022
Water Service Inspection - R Passed 6/3/2022 (8:00) 6/3/2022 06/02/2022
Misc
Resolved
06/02/2022
Water service ran to foundation must not though foundation wall.
Electrical Service Inspection Passed 10/6/2022 10/6/2022 10/06/2022
Gas Service Inspection - Residential Passed 10/6/2022 10/6/2022 10/06/2022
Erosion Control Inspection Residential Failed 10/6/2022 10/06/2022
Misc
Resolved
10/06/2022
Erosion control back in compliance at time of inspection. Mitchell Schwarz 05/11/2022 11:33 AM
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/06/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/06/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Failed 10/6/2022 10/6/2022 10/06/2022
Misc
Corrective Action Required
10/06/2022
NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE -sheathing breaks to occur in the middle 24” of the portal leg -studs at pfh over notched for exterior lighting fixture -uncover covered pfh to inspect nailing -missing top plate under header at pfh -boca plate protection for dwv at top plate S garage wall -fireblock dead space in mud hall -seal penetrations in stud space for return air in hall/owner’s closet -fireblock hvac chase to ceiling space and between floors -address ceiling joists in owners bedroom not supported properly -midway strap all 2” or less diameter dwv in stud spaces. See master bath -fire block west master bath wall to ceiling space -fireblock shower wall in master to ceiling space -fire block master toilet/garage wall to ceiling space -properly secure steel columns on main floor -fire block bed 4 walls to ceiling space -fireblock stairwell wall to ceiling space -fireblock bed 3 to ceiling space -finish framing for bed 3 bath -fireblock bed 4 walls to ceiling space -address rafters landing on 4 blocks in bed 4 -fireblock bed 5 walls to ceiling space -complete bath fan installs -level and secure columns in basement -solid blocking under kitchen island per plans
All Rough Inspection - Residential Failed 10/21/2022 10/21/2022 10/21/2022
Misc
Corrective Action Required
10/06/2022
-address ceiling joists in owners bedroom not supported properly provided hangers for joists for furr down span over 4’ -fireblock bed 5 walls to ceiling space see dead space at bed 4,5 and bath OKAY TO INSULATE
Miscellaneous Inspection Passed 10/25/2022 10/25/2022
Misc
Informational
10/25/2022
met with Craig to discuss inspection items. Mitchell Schwarz 10/25/2022 1:47 PM
All Rough Inspection - Residential Passed 10/26/2022 10/26/2022 10/26/2022
Misc
Resolved
10/26/2022
-address ceiling joists in owners bedroom not supported properly provided hangers for joists for furr down span over 4’ -fireblock bed 5 walls to ceiling space see dead space at bed 4,5 and bath OKAY TO INSULATE
Driveway Inspection Partial 11/15/2022 11/15/2022 11/15/2022
Misc
Informational
11/15/2022
11-15-22 RH. Driveway is formed up and aggregate is placed and compacted. Contractor has blankets for the driveway after they pour.
Driveway Inspection Passed 11/22/2022 11/22/2022 12/13/2022
Misc
Informational
11/15/2022
11-15-22 RH. Driveway is formed up and aggregate is placed and compacted. Contractor has blankets for the driveway after they pour. 12-13-22 RH. Driveway passed LS specification.
Erosion Control Inspection Residential Failed 2/22/2023 02/22/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Resolved
02/22/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Not Ready 3/3/2023 3/3/2023 03/03/2023
Misc
Corrective Action Required
03/03/2023
Inspection denied No address posted.
SEC. 7-1403 PREMISES IDENTIFICATION
Corrective Action Required
03/03/2023
Approved numbers or addresses shall be provided for all new dwelling unit structures in such a position as to be plainly visible and legible from the street or road fronting the property. Each dwelling unit within a multiple dwelling unit structure shall be identified at the main entry with premises identification unique to each dwelling unit. Residential dwelling units and structures housing multiple dwelling units accessed by private drive(s) or parking lot(s) shall also provide approved numbers or addresses in such a position as to be plainly visible and legible from such drive(s) or parking lot(s). Approved numbers or address characters shall be a minimum height of 4 inches (76 mm) and minimum stroke of 0.5 inches (12.7 mm). Approved numbers or address characters shall be of a contrasting color to the background itself.
Erosion Control Inspection Residential Passed 3/8/2023 03/08/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Failed 3/8/2023 3/8/2023 03/08/2023
Misc
Corrective Action Required
03/08/2023
-Add gravel to egress window well -No egress ladder -Seal all exterior wall penetrations -No stairs at covered patio -Secure A/C whip within 12" of disconnect box -Missing range hood/loose wiring -No sod installed -Splash pads not installed -Pay all fees
Misc
Resolved
03/08/2023
Occupancy Inspection - Codes Residential Failed 3/8/2023 03/08/2023
Misc
Corrective Action Required
03/08/2023
-Add gravel to egress window well -No egress ladder -Seal all exterior wall penetrations -No stairs at covered patio -Secure A/C whip within 12" of disconnect box -Missing range hood/loose wiring -No sod installed -Splash pads not installed -Pay all fees
Occupancy Inspection - Codes Residential Failed 4/14/2023 4/14/2023 04/14/2023
Misc
Corrective Action Required
03/08/2023
-Seal all exterior wall penetrations -Secure A/C whip within 12" of disconnect -Splash pads not installed -Pay all fees
Corrective Action Required
04/14/2023
Piers/Caissons Inspection - Residential Passed 4/19/2023 04/19/2023
Misc
Informational
04/19/2023
third party inspection performed.
Plot Plan Inspection Passed 04/19/2023
Occupancy Inspection - Codes Residential Full C of O 4/19/2023 4/19/2023 04/19/2023
Misc
Resolved
04/19/2023
-Seal all exterior wall penetrations -Secure A/C whip within 12" of disconnect -Splash pads not installed -Pay all fees
Documents & Images
Date Uploaded File Type Document Name
12/09/2021 HKF75_001
12/10/2021 Permit Codes Residential Plan Review
12/10/2021 Approved Plans APPROVED PLANS
12/10/2021 Plot Plan APPROVED PLOT PLAN
12/10/2021 Permit Codes Residential Plan Review
12/10/2021 Permit DS Building Permit
12/10/2021 Receipt Receipt for transaction:2021-009224
04/05/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
06/02/2022 Letter INSPECTION SUMMARY
06/02/2022 Letter INSPECTION SUMMARY
08/31/2022 2029 SW Red Barn Ln_DECK PIER INSP_2022-08-26
10/04/2022 Receipt Receipt for transaction:2022-008018
10/06/2022 Letter INSPECTION SUMMARY
10/06/2022 Letter INSPECTION SUMMARY
10/06/2022 Letter INSPECTION SUMMARY
10/06/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
10/26/2022 Letter INSPECTION SUMMARY
11/15/2022 Letter INSPECTION SUMMARY
12/13/2022 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
03/03/2023 Letter INSPECTION SUMMARY
03/08/2023 Letter INSPECTION SUMMARY
04/14/2023 Letter INSPECTION SUMMARY
04/18/2023 Receipt Receipt for transaction:2023-002152
04/19/2023 Letter INSPECTION SUMMARY
04/19/2023 Letter INSPECTION SUMMARY
04/19/2023 Letter INSPECTION SUMMARY
04/19/2023 Letter INSPECTION SUMMARY
04/19/2023 Letter Field Certificate of Occupancy
04/19/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home