Summary
PRRES20215743
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
11/03/2021
12/08/2021
05/02/2022
04/10/2023
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
Curtis Tate, Address:PO box 942   
TEAGUE ELECTRIC CONSTRUCTION INC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
CURTIS@SABHOMES.COM  
Zack Bryant, Address:200 NW Commerce Court  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $390.00 $390.00 Paid 12/08/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 12/08/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/08/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 12/08/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 12/08/2021
9110078-Valuation Fee New Single Family $925.37 $925.37 Paid 12/08/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/02/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/20/2021 12/20/2021
Sewer Service Inspection - R Passed 12/22/2021 (11:00) 12/22/2021 12/22/2021
Underslab Plumbing Inspection - Residential Passed 12/22/2021 12/22/2021 12/22/2021
Piers/Caissons Inspection - Residential Passed 2/10/2022 (1:00) 2/10/2022 02/10/2022
Water Service Inspection - R Passed 4/12/2022 (1:00) 4/12/2022 04/12/2022
All Rough Inspection - Residential Failed 5/5/2022 5/5/2022 05/05/2022
Miscellaneous Correction
Corrective Action Required
05/05/2022
- fire block end of I beam at bedroom 2 - Fire block floor at triangle chase near hall bathroom - Complete plumbing for master tub - Fire block penetration at master bathroom floor at tub - Secure wiring at fire place - Vent DWV laundry, master toilet and shower is one big loop - Fire block soffit short return wall bedroom 3 - Anchor bolt middle 1/3 of plate bedroom 3 - Seal plenum space at electrical bedroom 4 closet - 2 steel columns on pads C in basement plan’s call for 3 1/2” and 3” are installed
Electrical Service Inspection Passed 5/5/2022 5/5/2022 05/05/2022
Gas Service Inspection - Residential Passed 5/5/2022 5/5/2022 05/05/2022
All Rough Inspection - Residential Failed 5/13/2022 5/13/2022 05/13/2022
Miscellaneous Correction
Corrective Action Required
05/05/2022
- fire block end of I beam at bedroom 2-not done - Fire block floor at triangle chase near hall bathroom-Seal gaps - Complete plumbing for master tub - Fire block penetration at master bathroom floor at tub - Vent DWV laundry, master toilet and shower is one big loop-NOT DONE. VENT THIS THROUGH ROOF - Anchor bolt middle 1/3 of plate bedroom 3-See window - Seal plenum space at electrical bedroom 4 closet-Pan off and seal at dwv above soffit
All Rough Inspection - Residential Failed 5/17/2022 5/17/2022 05/17/2022
Miscellaneous Correction
Corrective Action Required
05/13/2022
- Fire block floor at triangle chase near master bath and hall - Complete plumbing for master tub - Fire block penetration at master bathroom floor at tub - Anchor bolt middle 1/3 of plate bedroom 3-See window
All Rough Inspection - Residential Not Ready 5/18/2022 5/18/2022 05/18/2022
Miscellaneous Correction
Corrective Action Required
05/17/2022
- Fire block floor at triangle chase near master bath and hall - Complete plumbing for master tub Okay to insulate
Erosion Control Inspection Residential Failed 5/18/2022 05/18/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/18/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/18/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 05/18/2022 11:10 AM
Erosion Control Inspection Residential Partial 5/23/2022 5/23/2022 05/23/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/23/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Resolved
05/23/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 05/18/2022 11:10 AM
Misc
Informational
05/23/2022
Erosion control back in compliance at time of inspection. Mitchell Schwarz 05/23/2022 11:47 AM
All Rough Inspection - Residential Passed 5/31/2022 5/31/2022 05/31/2022
Miscellaneous Correction
Resolved
05/31/2022
- Fire block floor at triangle chase near master bath and hall - Complete plumbing for master tub Okay to insulate
Driveway Inspection Partial 8/18/2022 8/18/2022 08/18/2022
Misc
Informational
08/18/2022
8.18.2022 I performed a driveway inspection and pass the sub-grade to pour concrete.
Sidewalk Inspection Partial 8/18/2022 8/18/2022 08/18/2022
Misc
Informational
08/18/2022
8.18.2022 i performed a sidewalk inspection and pass the subgrade to pour concrete
Driveway Inspection Passed 8/24/2022 8/24/2022 08/24/2022
Misc
Informational
08/18/2022
8.18.2022 I performed a driveway inspection and pass the sub-grade. 8-24-22 RH. Driveway meets LS and ADA specification.
Sidewalk Inspection Passed 8/24/2022 08/24/2022
Misc
Informational
08/18/2022
8.18.2022 i performed a sidewalk inspection and pass the subgrade to pour concrete 8-24-22 RH. Sidewalk meets LS and ADA specification.
Occupancy Inspection - Codes Residential Failed 1/23/2023 1/23/2023 01/23/2023
Misc
Corrective Action Required
01/23/2023
-sod -splash blocks and sump pump discharge to extend 36” from foundation -spark ring for outlet above fireplace -secondary locking device at rear sliders -address water heater wiring/insulation -handrail at rear patio stairs -landing for top of patio steps -provide as build plot plan -lock out for all hardwired appliances
Erosion Control Inspection Residential Passed 04/07/2023
Misc
Resolved
04/07/2023
Erosion control back in compliance at time of inspection. Mitchell Schwarz 05/23/2022 11:47 AM
Occupancy Inspection - Codes Residential Failed 4/7/2023 4/7/2023 04/07/2023
Misc
Corrective Action Required
01/23/2023
-handrail at rear patio stairs -lock out for all hardwired appliances
Plot Plan Inspection Passed 4/10/2023 04/07/2023
Occupancy Inspection - Codes Residential Full C of O 4/10/2023 4/10/2023 04/10/2023
Misc
Resolved
04/10/2023
-handrail at rear patio stairs -lock out for all hardwired appliances
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home