Summary
PRRES20215616
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 12/09/2021 12:00 AM by username 'Michael Harkins'. STOP WORK ORDER removed on 12/09/2021 12:00 AM by username 'Michael Harkins'.
10/27/2021
11/01/2021
04/25/2022
10/13/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
michael@summithomeskc.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,133.14 $1,133.14 Paid 11/01/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/01/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 11/01/2021
8331507-Sewer Connection Fee $450.00 $450.00 Paid 11/01/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 11/01/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 11/01/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/28/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/28/2022
Outstanding Fees Amount Paid Owing Date Paid
9110080-Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$75.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 12/8/2021 (2:00) 12/8/2021 12/08/2021
Water Service Inspection - R Passed 12/9/2021 (11:30) 12/9/2021 12/09/2021
Erosion Control Inspection Residential Failed 12/9/2021 12/09/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/09/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Footing Inspection - Residential Failed - Stop Work 12/9/2021 12/09/2021
Misc
Corrective Action Required
12/09/2021
NO FOOTING INSPECTION ON RECORD SUBMIT 3RD PARTY FOOTING INSPECTION WITHIN 48 HOURS OF POUR
Footing Inspection - Residential Passed 12/9/2021 12/09/2021
Misc
Resolved
12/09/2021
NO FOOTING INSPECTION ON RECORD SUBMIT 3RD PARTY FOOTING INSPECTION WITHIN 48 HOURS OF POUR
Misc
Corrective Action Required
12/09/2021
3RD PARTY FOOTING BY DEREK PEREZ @ EVERSTEAD SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED NEAR SOUTHEAST ( REAR RIGHT) CORNER OF GARAGE FOUNDATION WALL
Underslab Plumbing Inspection - Residential Passed 12/27/2021 12/27/2021 12/27/2021
Erosion Control Inspection Residential Failed 3/22/2022 03/22/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/09/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/22/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. MAINTAIN SILT FENCE CLEN STREET
Electrical Service Inspection Passed 5/3/2022 5/3/2022 05/03/2022
Gas Service Inspection - Residential Failed 5/3/2022 5/3/2022 05/03/2022
Miscellaneous Correction
Corrective Action Required
05/03/2022
PROVIDE MIN 10 PSI FOR 15 MIN HAS 0 PSI
All Rough Inspection - Residential Failed 5/3/2022 5/3/2022 05/03/2022
Miscellaneous Correction
Corrective Action Required
05/03/2022
No deck pier inspection on record Provide (2) 2x6 cedar post to ridge beam per plan front porch Install front door Nail intersecting wall corners per code throughout Truss screws shall run through double top plate SW corner bed 2 Strap top plate break above shower bath 2 Engineer to address field modifications to trusses at foyer/ garage Seal fire block dead space bed 1 closet Provide (4) stud pack at girder truss bearing point bed 1 Provide LIB behind bedroom 1 door per plan Provide 2 nails in LIB at bottom plate laundry room Provide stud shoe washing machine drain Truss screws shall extend through double top plate laundry girder Tighten anchor bolts garage Anchor bolts shall be in middle 1/3 the width of plate Nail exterior wall sheathing above 2 car overhead door Seal exterior penetration line set near water shut off Tighten anchor bolt basement near line set Repair supply air rec room basement Seal fire block at dwv above wet bar Install patio door basement Provide (3) 2x6 under beam bed 3/patio door Tighten anchor bolt at bed 3 window Seal fire blocking at foundation wall bed 4 & bed 4 closet
Gas Service Inspection - Residential Not Ready 5/12/2022 5/12/2022 05/12/2022
Miscellaneous Correction
Corrective Action Required
05/03/2022
PROVIDE MIN 10 PSI FOR 15 MIN HAS 0 PSI- -5/12/22 Still no pressure
All Rough Inspection - Residential Failed 5/12/2022 5/12/2022 05/12/2022
Miscellaneous Correction
Corrective Action Required
05/03/2022
-POST ADDRESS BEFORE ANY FURTHER INSPECTIONS -No deck pier inspection on record -Engineer to address field modifications to trusses at foyer/ garage -Provide (4) stud pack at girder truss bearing point bed 1-REPAIR OVERNOTCHED STUD AND NAIL PER CODE -Provide stud shoe washing machine drain-USE MANUFACTURER REQUIRED FASTENERS -Truss screws shall extend through double top plate laundry girder-ADDRESS SCREW COMING OUT OF THE SIDE OF THE -Nail exterior wall sheathing above 2 car overhead door-SEE VERTICAL SEAMS -Tighten anchor bolt basement near line set-NOT DONE -Provide (3) 2x6 under beam bed 3/patio door-NOT DONE
All Rough Inspection - Residential Not Ready 5/19/2022 5/19/2022 05/19/2022
Miscellaneous Correction
Corrective Action Required
05/12/2022
-Provide stud shoe washing machine drain-USE MANUFACTURER REQUIRED FASTENERS -Tighten anchor bolt basement near line set-NOT DONE
Piers/Caissons Inspection - Residential Passed 5/19/2022 05/19/2022
Misc
Corrective Action Required
05/19/2022
Approved by Bradley Huxol on 5-11-22
Gas Service Inspection - Residential Passed 5/19/2022 5/19/2022 05/19/2022
Miscellaneous Correction
Resolved
05/19/2022
PROVIDE MIN 10 PSI FOR 15 MIN HAS 0 PSI- -5/12/22 Still no pressure
All Rough Inspection - Residential Passed 5/20/2022 5/20/2022 05/20/2022
Miscellaneous Correction
Resolved
05/20/2022
-Provide stud shoe washing machine drain-USE MANUFACTURER REQUIRED FASTENERS -Tighten anchor bolt basement near line set-NOT DONE
Driveway Inspection Partial 6/29/2022 6/29/2022 06/29/2022
Misc
Informational
06/29/2022
Driveway was framed up with aggregate in and compacted. 6/29/22 ES
Sidewalk Inspection Partial 8/17/2022 06/29/2022
Misc
Informational
06/29/2022
Sidewalk was framed up with aggregate in and compacted. This is just the right side of driveway. 6/29/22 ES
Driveway Inspection Passed 7/8/2022 7/8/2022 07/08/2022
Misc
Informational
06/29/2022
Driveway was framed up with aggregate in and compacted. 6/29/22 ES Driveway meets LS and ADA spec. 7/8/22 ES
Sidewalk Inspection Partial 7/8/2022 7/8/2022 07/08/2022
Misc
Informational
07/08/2022
Sidewalk was framed up with aggregate in and compacted. 6/29/22 ES
Plot Plan Inspection Passed 8/2/2022 08/02/2022
Occupancy Inspection - Codes Residential Failed 9/16/2022 9/16/2022 09/16/2022
Miscellaneous Correction
Corrective Action Required
09/16/2022
Pay not ready fees Sidewalk inspection still pending Provide guardrail or raise grade to less than 30" front stoop Remove dust covers smoke detectors Nail joist hanger under deck landing Provide 1 1/2 bearing deck beam Provide (2) through bolts deck beam to post connection Provide tamper proof caps AC condenser Clean street & curbs of dirt & debris
Sidewalk Inspection Passed 9/28/2022 9/28/2022 09/27/2022
Misc
Informational
07/08/2022
Sidewalk was framed up with aggregate in and compacted. 6/29/22 ES South(right side of driveway) sidewalk meets LS and ADA spec. Leaving as partial until north part of sidewalk is completed. 7/8/22 ES South side of driveway was poured without inspection. From surface it meets LS/ADA specs. 9/27/22 ES
Sidewalk Inspection Passed 9/27/2022 09/27/2022
Misc
Informational
07/08/2022
Sidewalk was framed up with aggregate in and compacted. 6/29/22 ES South(right side of driveway) sidewalk meets LS and ADA spec. Leaving as partial until north part of sidewalk is completed. 7/8/22 ES North side of sidewalk was poured without inspection. From surface appears to meet LS/ADA specs. 9/27/22 ES
Occupancy Inspection - Codes Residential Not Ready 9/29/2022 9/29/2022 09/29/2022
Miscellaneous Correction
Corrective Action Required
09/16/2022
Provide 1 1/2 bearing deck beam Provide (2) through bolts deck beam to post connection
Occupancy Inspection - Codes Residential Full C of O 10/13/2022 10/13/2022 10/13/2022
Miscellaneous Correction
Resolved
10/13/2022
Provide 1 1/2 bearing deck beam Provide (2) through bolts deck beam to post connection
Documents & Images
Date Uploaded File Type Document Name
10/27/2021 W0 #123 - Permit App
10/27/2021 Permit Codes Residential Plan Review
11/01/2021 Plot Plan Approved Plot Plan
11/01/2021 Approved Plans Approved Drawings
11/01/2021 Approved Plans Approved Truss Layout
11/01/2021 Approved Plans Approved Truss Pacakge
11/01/2021 Permit Codes Residential Plan Review
11/01/2021 Permit DS Building Permit
11/01/2021 Receipt Receipt for transaction:2021-008406
12/08/2021 Letter INSPECTION SUMMARY
12/08/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter Stop Work Order
12/09/2021 123 Woodside Ridge FTNG
12/20/2021 Letter INSPECTION SUMMARY
12/27/2021 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
05/03/2022 Letter INSPECTION SUMMARY
05/03/2022 Letter INSPECTION SUMMARY
05/03/2022 Letter INSPECTION SUMMARY
05/11/2022 Deck Pier Inspection-123
05/12/2022 Letter INSPECTION SUMMARY
05/12/2022 Letter INSPECTION SUMMARY
05/18/2022 Approved Plans Approved Truss Repair
05/19/2022 Letter INSPECTION SUMMARY
05/19/2022 Letter INSPECTION SUMMARY
05/19/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
07/08/2022 Letter INSPECTION SUMMARY
07/08/2022 Letter INSPECTION SUMMARY
07/08/2022 Letter INSPECTION SUMMARY
08/01/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
08/02/2022 Letter INSPECTION SUMMARY
09/16/2022 Letter INSPECTION SUMMARY
09/27/2022 Letter INSPECTION SUMMARY
09/27/2022 Letter INSPECTION SUMMARY
09/28/2022 Receipt Receipt for transaction:2022-007851
09/29/2022 image
09/29/2022 image0
09/29/2022 image1
09/29/2022 Letter INSPECTION SUMMARY
10/12/2022 123 woodside ridge letter
10/13/2022 Letter Field Certificate of Occupancy
10/13/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home