Permit Application Status

PRRES20215494


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215494
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE. UNFNISHED BASEMENT. COVERED PATIO. ROOF TRUSSES.
10/20/2021
10/25/2021
10/14/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
michael@summithomeskc.com  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $600.00 $600.00 Paid 10/25/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/25/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/25/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/25/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/25/2021
9110078-Valuation Fee New Single Family $1,494.26 $1,494.26 Paid 10/25/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/28/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/12/2021 (11:00) 11/12/2021 11/12/2021
Sewer Service Inspection - R Passed 12/7/2021 (8:30) 12/7/2021 12/07/2021
Water Service Inspection - R Passed 12/8/2021 (1:15) 12/8/2021 12/08/2021
Underslab Plumbing Inspection - Residential Passed 12/20/2021 12/20/2021 12/20/2021
Erosion Control Inspection Residential Failed 4/1/2022 04/01/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/01/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER CLEAN STREET OF MUD, GRAVEL & DEBRIS
Electrical Service Inspection Passed 5/11/2022 5/11/2022 05/11/2022
Gas Service Inspection - Residential Not Ready 5/11/2022 5/11/2022 05/11/2022
Misc
Corrective Action Required
05/11/2022
provide a minium 10psi at gas gauge for inspection
Erosion Control Inspection Residential Failed 5/11/2022 05/11/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/11/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER CLEAN STREET OF MUD, GRAVEL & DEBRIS
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/11/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -maintain gravel filter -maintain silt fence
All Rough Inspection - Residential Failed 5/11/2022 5/11/2022 05/11/2022
Misc
Corrective Action Required
05/11/2022
NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE -anchor bolts to be in the middle 1/3 of sill plate -cspf per plans at bed 5 N wall -seal top plate penetration rear wall bed 5 -strap top plate bed 5 closet where top plate lapped less than 24” -fire block hvac chase with 6” pipe and pex, to furr down in garage -fireblock hvac chase at great room windows to furr down and ceiling above -cs-pf at rear great room windows -4 stud place under lvl and double joist at great room to dining room per plans -missing nails in hanger for joist at great room to stairwell wall -4 2x4 at great room/stairwell wall per plans -seal gap into furr down in garage from dining room -provide 30” head clearance at attic access -fireblock hvac chase at master to ceiling -address hole in floor at laundry -plans show doorway from laundry to master bath. (Not framed to plans) -missing hus24 hangers bed 2 -missing hold downs master closet (gt truss and others) -missing steel column at stairwell -anchor all steel columns in basement -nail exterior sheathing to plans/code
All Rough Inspection - Residential Failed 5/20/2022 5/20/2022 05/20/2022
Misc
Corrective Action Required
05/11/2022
-fireblock hvac chase at great room windows to furr down and ceiling above [near fire pllace] -seal gap into furr down in garage from dining room -provide 30” head clearance at attic access -missing steel column at stairwell -nail exterior sheathing to plans/code
Gas Service Inspection - Residential Failed 5/20/2022 5/20/2022 05/20/2022
Misc
Resolved
05/19/2022
provide a minium 10psi at gas gauge for inspection 5/20/22 2 lb. At inspection
All Rough Inspection - Residential Passed 5/24/2022 5/24/2022 05/24/2022
Misc
Resolved
05/24/2022
-provide 30” head clearance at attic access - -nail exterior sheathing to plans/co
Gas Service Inspection - Residential Passed 5/24/2022 05/24/2022
Driveway Inspection Partial 6/7/2022 6/7/2022 06/07/2022
Misc
Informational
06/07/2022
Driveway was framed up with aggregate in and compacted. 6/7/22
Plot Plan Inspection Passed 8/19/2022 08/19/2022
Erosion Control Inspection Residential Failed 8/19/2022 08/19/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/19/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -maintain gravel filter -maintain silt fence
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/19/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. erosion control must be maintained until sod is in place
Driveway Inspection Passed 9/28/2022 9/28/2022 09/27/2022
Misc
Informational
06/07/2022
Driveway was framed up with aggregate in and compacted. 6/7/22 Driveway meets LS spec. 9/27/22 ES
Erosion Control Inspection Residential Passed 9/30/2022 09/30/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/19/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. erosion control must be maintained until sod is in place
Occupancy Inspection - Codes Residential Failed 9/30/2022 9/30/2022 09/30/2022
Miscellaneous Correction
Corrective Action Required
09/30/2022
Complete seal exterior light fixtures & meter can Provide tamper proof caps A/C condenser Provide 6" clearance wood siding to grade Nail joist hangers above furnace Replace broken window breakfast nook Handrail height, measured vertically from the sloped plane adjoining the tread nosing, shall be not less than 34 inches and not more than 38 inches ( 2018 IRC R311.7.8.1) :between landings to second story: Handrails shall be provide on not less than side of each flight of stairs with four or more risers basement landing ( 2018 IRC R311.7.8) Provide protection above both service panels to avoid damage to the electrical equipment from condensation, leaks and breaks in such foreign systems HVAC & Plumbing ( 2018 IRC E3405.3, figure 3405.1 ) Provide gravel water meter pit & place lid over pit
Occupancy Inspection - Codes Residential Failed 10/12/2022 10/12/2022 10/12/2022
Miscellaneous Correction
Corrective Action Required
09/30/2022
Handrails shall be provide on not less than side of each flight of stairs with four or more risers basement landing ( 2018 IRC R311.7.8)
Piers/Caissons Inspection - Residential Passed 10/14/2022 10/14/2022
Misc
Informational
10/14/2022
poured with footing
Occupancy Inspection - Codes Residential Full C of O 10/14/2022 10/14/2022 10/14/2022
Miscellaneous Correction
Resolved
10/14/2022
Documents & Images
Date Uploaded File Type Document Name
10/20/2021 W0 #137 - Permit App
10/21/2021 Approved Plans APPROVED DRAWINGS
10/21/2021 Approved Plans APPROVED TRUSS PACKAGE
10/21/2021 Approved Plans APPROVED TRUSS LAYOUT
10/25/2021 Permit Codes Residential Plan Review
10/25/2021 Permit DS Building Permit
10/25/2021 Receipt Receipt for transaction:2021-008203
11/12/2021 Letter INSPECTION SUMMARY
12/07/2021 Letter INSPECTION SUMMARY
12/08/2021 Letter INSPECTION SUMMARY
12/20/2021 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
08/18/2022 Plot Plan APPROVED AS BUILT PLOT PLAN
08/19/2022 Letter INSPECTION SUMMARY
08/19/2022 Letter INSPECTION SUMMARY
09/27/2022 Letter INSPECTION SUMMARY
09/28/2022 Receipt Receipt for transaction:2022-007853
09/30/2022 LOT 137 ASBUILT
09/30/2022 WO137backflow
09/30/2022 Letter INSPECTION SUMMARY
10/12/2022 Letter INSPECTION SUMMARY
10/13/2022 137rail_pdf
10/14/2022 Letter INSPECTION SUMMARY
10/14/2022 Letter Field Certificate of Occupancy
10/14/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home