Permit Application Status

PRRES20215334


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215334
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO STOP WORK ORDER generated on 03/29/2022 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 05/12/2022 12:00 AM by username 'Mitchell Schwarz'.
10/12/2021
10/27/2021
04/11/2022
04/04/2023
Locations
Contacts
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
Jennifer Pestka, Address:p o box 6423  
JENNIFER@IQHOMEBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $450.00 $450.00 Paid 10/27/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/27/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/27/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/27/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/27/2021
9110078-Valuation Fee New Single Family $1,083.85 $1,083.85 Paid 10/27/2021
$0.00 $0.00 $0.00 N/A
$0.00 $0.00 $0.00 N/A
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/27/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/27/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/03/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 02/06/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 04/04/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/4/2021 (10:30) 11/4/2021 11/04/2021
Underslab Plumbing Inspection - Residential Passed 1/4/2022 1/4/2022 01/04/2022
Erosion Control Inspection Residential Failed 2/10/2022 02/10/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/10/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Sewer Service Inspection - R Passed 3/15/2022 (1:00) 3/15/2022 03/15/2022
Water Service Inspection - R Passed 3/16/2022 (2:00) 3/16/2022 03/16/2022
Erosion Control Inspection Residential Failed 3/24/2022 03/24/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/10/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. erosion control still not in compliance stop work issued Mitchell Schwarz 03/29/2022 11:25 AM
Erosion Control Inspection Residential Failed - Stop Work 3/29/2022 03/29/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/24/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
03/29/2022
Erosion control still not in compliance stop work issued Mitchell Schwarz 03/29/2022 11:25 AM
Erosion Control Inspection Residential Not Ready 4/15/2022 04/15/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/29/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
03/29/2022
Erosion control still not in compliance stop work issued Mitchell Schwarz 03/29/2022 11:25 AM
Misc
Corrective Action Required
04/15/2022
erosion control still not in compliance Mitchell Schwarz 04/15/2022 8:55 AM
Piers/Caissons Inspection - Residential Failed 4/15/2022 04/15/2022
Misc
Corrective Action Required
04/15/2022
inspection denied, erosion control not in compliance from stop work order issued on 3/29/22 Mitchell Schwarz 04/15/2022 8:56 AM
Erosion Control Inspection Residential Partial 5/12/2022 5/12/2022 05/12/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
05/12/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Resolved
05/12/2022
Erosion control still not in compliance stop work issued Mitchell Schwarz 03/29/2022 11:25 AM
Misc
Resolved
05/12/2022
erosion control still not in compliance Mitchell Schwarz 04/15/2022 8:55 AM
Misc
Informational
05/12/2022
Erosion control in compliance at time of inspection Mitchell Schwarz 05/12/2022 11:06 AM
Electrical Service Inspection Failed 5/13/2022 5/13/2022 05/13/2022
Misc
Corrective Action Required
05/13/2022
INSPECTION DENIED, NOT READY FOR INSPECTION
Gas Service Inspection - Residential Failed 5/13/2022 5/13/2022 05/13/2022
Misc
Corrective Action Required
05/13/2022
INSPECTION DENIED, NOT READY FOR INSPECTION
All Rough Inspection - Residential Not Ready 5/13/2022 5/13/2022 05/13/2022
Misc
Corrective Action Required
05/13/2022
INSPECTION DENIED, NOT READY FOR ALL ROUGH INSPECTION, ADDRESS CORRECTIONS BELOW BEFORE RESCHEDULING INSPECTION -repair damaged sections silt fence -garage portal covered, expose nail pattern at sheathing and straps embedded in concrete for inspection -fur out at garage HVAC wall to allow for insulation -Complete all fur downs at HVAC garage wall and fur down ceiling for insulation -provide protection plate bottom plate DWV garage wall -seal all top plate penetrations -provide protection plates all NM 1 1/4” or less from end of stud -secure/support all electrical per code -construction trash piled up garage single bay unable to inspect -complete all fireblocking -anchor bolts required within 12” of plate breaks -security blocking exterior door -seal all penetrations through air returns -support hips garage -address all ceiling joists taper cut more than 25% -address rafters landing on blocks **THIS IS AN INCOMPLETE LIST AND SUBJECT TO ADDITIONAL CORRECTIONS**
Erosion Control Inspection Residential Failed 5/13/2022 5/13/2022 05/13/2022
Misc
Corrective Action Required
05/13/2022
-repair damaged sections silt fence
Electrical Service Inspection Passed 6/6/2022 6/6/2022 06/06/2022
Misc
Resolved
06/06/2022
INSPECTION DENIED, NOT READY FOR INSPECTION
Gas Service Inspection - Residential Failed 6/6/2022 6/6/2022 06/06/2022
Misc
Resolved
06/06/2022
INSPECTION DENIED, NOT READY FOR INSPECTION
Misc
Corrective Action Required
06/06/2022
-Provide access to gas pressure gauge for inspection -Bond gas line
All Rough Inspection - Residential Failed 6/6/2022 6/6/2022 06/06/2022
Misc
Corrective Action Required
05/13/2022
-support hips garage -address all ceiling joists taper cut more than 25% -all anchor bolts to be within the middle 1/3 of sill plate -uncover to view all nailing at PFG -fireblock kitchen wall to furr down in garage -seal all penetrations in joist space above kitchen used for return air -missing nails in hanger above kitchen/dining -uncover covered patio or proved way to view -seal bottom plate penetrations at thermostat -missing nail in hanger at lvl above foyer/great room -seal gaps in fire blocking. Foyer wall into garage furr down -strap top plate at read master bedroom where lapped less than 24” -fireblock top of furr out wall in laundry -fire block furr out wall at basement stairwell landing -anchor steel column in basement -provide access to gas pressure gauge for inspection -bond gas line
All Rough Inspection - Residential Failed 6/21/2022 6/21/2022 06/21/2022
Misc
Corrective Action Required
06/06/2022
-support hips garage-NOT DONE -address all ceiling joists taper cut more than 25%-NOT ADDRESSED -uncover covered patio or proved way to view-PROVIDE COLLAR TIES 4’ OC, -fireblock top of furr out wall in laundry -USE APPROVED MATERIALS AND METHODS -fire block furr out wall at basement stairwell landing-SEE UPPER LANDING -anchor steel column in basement-NOT DONE -bond gas line-IDENTIFY CONDUCTOR AT BOTH ENDS
Gas Service Inspection - Residential Passed 6/21/2022 6/21/2022 06/21/2022
Misc
Resolved
06/21/2022
-Provide access to gas pressure gauge for inspection -Bond gas line
All Rough Inspection - Residential Failed 7/13/2022 7/13/2022 07/13/2022
Misc
Corrective Action Required
06/21/2022
-support hips garage-NOT DONE -address all ceiling joists taper cut more than 25%-NOT ADDRESSED -uncover covered patio or proved way to view-PROVIDE COLLAR TIES 4’ OC, -fireblock top of furr out wall in laundry -USE APPROVED MATERIALS AND METHODS -fire block furr out wall at basement stairwell landing-SEE UPPER LANDING -anchor steel column in basement-NOT DONE -bond gas line-IDENTIFY CONDUCTOR AT BOTH ENDS
Misc
Corrective Action Required
07/13/2022
INSPECTION DENIED EROSION CONTROL NOT IN COMPLIANCE. Mitchell Schwarz 07/13/2022 10:48 AM
Erosion Control Inspection Residential Failed 7/13/2022 07/13/2022
Misc
Resolved
07/13/2022
-repair damaged sections silt fence
DCM5 ESC INSP DENIED
Corrective Action Required
07/13/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -MAINTAIN SILT FENCE -MAINTAIN VEGETATION Mitchell Schwarz 07/13/2022 10:50 AM
All Rough Inspection - Residential Failed 7/15/2022 7/15/2022 07/15/2022
Misc
Corrective Action Required
07/13/2022
-support hips garage-NOT DONE -address all ceiling joists taper cut more than 25%-NOT ADDRESSED -uncover covered patio or proved way to view-PROVIDE COLLAR TIES 4’ OC, -fireblock top of furr out wall in laundry -USE APPROVED MATERIALS AND METHODS -fire block furr out wall at basement stairwell landing-SEE UPPER LANDING -anchor steel column in basement-NOT DONE -bond gas line-IDENTIFY CONDUCTOR AT BOTH ENDS
Misc
Corrective Action Required
07/13/2022
INSPECTION DENIED EROSION CONTROL NOT IN COMPLIANCE. Mitchell Schwarz 07/13/2022 10:48 AM Still not in compliance 7/15/22 11:10AM
All Rough Inspection - Residential Passed 7/20/2022 7/20/2022 07/20/2022
Misc
Resolved
07/20/2022
-support hips garage-NOT DONE -address all ceiling joists taper cut more than 25%-NOT ADDRESSED -uncover covered patio or proved way to view-PROVIDE COLLAR TIES 4’ OC, -fireblock top of furr out wall in laundry -USE APPROVED MATERIALS AND METHODS -fire block furr out wall at basement stairwell landing-SEE UPPER LANDING -anchor steel column in basement-NOT DONE -bond gas line-IDENTIFY CONDUCTOR AT BOTH ENDS
Misc
Resolved
07/20/2022
INSPECTION DENIED EROSION CONTROL NOT IN COMPLIANCE. Mitchell Schwarz 07/13/2022 10:48 AM Still not in compliance 7/15/22 11:10AM
Piers/Caissons Inspection - Residential Passed 8/8/2022 (10:15) 8/8/2022 08/08/2022
Misc
Resolved
08/08/2022
inspection denied, erosion control not in compliance from stop work order issued on 3/29/22 Mitchell Schwarz 04/15/2022 8:56 AM
Driveway Inspection Partial 10/3/2022 10/03/2022
Misc
Informational
10/03/2022
10-3-22 RH. Driveway is formed up and aggregate is placed and compacted.
Sidewalk Inspection Partial 10/3/2022 10/03/2022
Misc
Informational
10/03/2022
10-3-22 RH. Sidewalk is formed up and aggregate is placed and compacted.
Driveway Inspection Passed 10/10/2022 10/10/2022 10/10/2022
Misc
Informational
10/03/2022
10-3-22 RH. Driveway is formed up and aggregate is placed and compacted. 10-10-22 RH. Driveway meets LS and ADA specification.
Sidewalk Inspection Partial 10/10/2022 10/10/2022 10/10/2022
Misc
Informational
10/10/2022
10-3-22 RH. Sidewalk is formed up and aggregate is placed and compacted.
Sidewalk Inspection Passed 10/17/2022 10/17/2022 10/17/2022
Misc
Informational
10/10/2022
10-3-22 RH. Sidewalk is formed up and aggregate is placed and compacted. 10-17-22 RH. Sidewalk meets LS and ADA specification.
Erosion Control Inspection Residential Failed 10/26/2022 10/26/2022
DCM5 ESC INSP DENIED
Resolved
10/26/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -MAINTAIN SILT FENCE -MAINTAIN VEGETATION Mitchell Schwarz 07/13/2022 10:50 AM
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/26/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 10/26/2022 1:22 PM
Occupancy Inspection - Codes Residential Failed 12/21/2022 12/21/2022 12/21/2022
Misc
Corrective Action Required
12/21/2022
NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE -erosion control to remain in place until sod -final grade and sod -obtain issued lawn irrigation permit -gutters -splash blocks and sump pump discharge to extend 36” from foundation -security screws at rear door -pressure relief valve pipe on water heater to close to ground
Plot Plan Inspection Passed 1/3/2023 01/03/2023
Erosion Control Inspection Residential Failed 1/3/2023 01/03/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
01/03/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 10/26/2022 1:22 PM
Misc
Corrective Action Required
01/03/2023
Remove portable restroom from side walk Clean side walk Erosion control to remain in place until sod is in place
Occupancy Inspection - Codes Residential Ready for Temp CO 1/3/2023 1/3/2023 01/03/2023
Misc
Corrective Action Required
12/21/2022
-gutters -splash blocks and sump pump discharge to extend 36” from foundation
Occupancy Inspection - Codes Residential Ready for Temp CO 2/2/2023 02/02/2023
Misc
Corrective Action Required
01/03/2023
Submit TCO extension request -Sod -gutters -splash blocks and sump pump discharge to extend 36” from foundation
Occupancy Inspection - Codes Residential Failed 3/8/2023 03/08/2023
Misc
Corrective Action Required
02/02/2023
Submit TCO extension request -Sod -splash blocks and sump pump discharge to extend 36” from foundation
Erosion Control Inspection Residential Passed 04/04/2023
Misc
Resolved
04/04/2023
Remove portable restroom from side walk Clean side walk Erosion control to remain in place until sod is in place
Occupancy Inspection - Codes Residential Full C of O 4/4/2023 4/4/2023 04/04/2023
Misc
Resolved
04/04/2023
Submit TCO extension request -Sod -splash blocks and sump pump discharge to extend 36” from foundation
Documents & Images
Date Uploaded File Type Document Name
10/12/2021 2043 SW Farm Field Ln - Tax Application
10/12/2021 2043 SW Farm Field Ln - Permit Application
10/12/2021 Approved Plans approved plans
10/13/2021 Permit Codes Residential Plan Review
10/14/2021 Plot Plan APPROVED PLOT PLAN
10/14/2021 Permit Codes Residential Plan Review
10/27/2021 Permit DS Building Permit
10/27/2021 Receipt Receipt for transaction:2021-008304
11/04/2021 Letter INSPECTION SUMMARY
01/04/2022 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter Stop Work Order
04/15/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
05/12/2022 Letter INSPECTION SUMMARY
05/13/2022 Letter INSPECTION SUMMARY
05/13/2022 Letter INSPECTION SUMMARY
05/13/2022 Letter INSPECTION SUMMARY
05/13/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/27/2022 Receipt Receipt for transaction:2022-005156
07/13/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
07/20/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
10/03/2022 Letter INSPECTION SUMMARY
10/03/2022 Letter INSPECTION SUMMARY
10/10/2022 Letter INSPECTION SUMMARY
10/10/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/26/2022 Letter INSPECTION SUMMARY
12/21/2022 Letter INSPECTION SUMMARY
01/03/2023 Letter INSPECTION SUMMARY
01/03/2023 Letter INSPECTION SUMMARY
01/03/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/03/2023 Receipt Receipt for transaction:2023-000013
02/06/2023 2043 SW Farm Field Ln - Extension Form
02/06/2023 Certificate/License Codes Temporary Certificate of Occupancy
02/06/2023 Receipt Receipt for transaction:2023-000677
02/28/2023 2043 SW Farm Field Ln - Extension Form
03/08/2023 Letter INSPECTION SUMMARY
04/04/2023 Certificate/License Codes Temporary Certificate of Occupancy
04/04/2023 Receipt Receipt for transaction:2023-001873
04/04/2023 Letter INSPECTION SUMMARY
04/04/2023 Letter Field Certificate of Occupancy
04/04/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: