Permit Application Status

PRRES20215320


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215320
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED WALKOUT BASEMENT. COVERED DECK. SUSPENDED STOOP. STOP WORK ORDER generated on 07/14/2022 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 11/29/2022 12:00 AM by username 'Mitchell Schwarz'.
10/11/2021
10/25/2021
04/11/2022
03/28/2023
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $420.00 $420.00 Paid 10/25/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/25/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/25/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/25/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/25/2021
9110078-Valuation Fee New Single Family $1,151.39 $1,151.39 Paid 10/25/2021
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/07/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/07/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/05/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 10/25/2021 (2:45) 10/25/2021 10/25/2021
Misc
Corrective Action Required
10/25/2021
west footing wall doesnt match approved plans
Sewer Service Inspection - R Passed 12/8/2021 12/08/2021
Erosion Control Inspection Residential Failed 12/9/2021 12/09/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/09/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Water Service Inspection - R Passed 12/9/2021 12/09/2021
Underslab Plumbing Inspection - Residential Passed 12/28/2021 12/28/2021 12/28/2021
Erosion Control Inspection Residential Failed 1/21/2022 01/21/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
01/21/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/21/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 01/21/2022 3:01 PM
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
01/21/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO INSPECTION(S) BEING PERFORMED.
Erosion Control Inspection Residential Failed 5/27/2022 05/27/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
05/27/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 01/21/2022 3:01 PM
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
05/27/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO INSPECTION(S) BEING PERFORMED.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/27/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -maintain silt fence Mitchell Schwarz 05/27/2022 10:31 AM
Electrical Service Inspection Passed 5/27/2022 5/27/2022 05/27/2022
Gas Service Inspection - Residential Passed 5/27/2022 5/27/2022 05/27/2022
All Rough Inspection - Residential Failed 5/27/2022 5/27/2022 05/27/2022
Misc
Corrective Action Required
05/27/2022
-install all windows and doors -remove covering at garage portal frame to inspect nailing to header -anchor bolts to be with in 12” of plate breaks but not closer than 7x the diameter of the bolt (add anchor bolt near stud pack W garage wall) -address hip rafters over notched at bearing ends in garage -missing nails in hangers above kitchen and dining area -address hip rafter to top plate above pantry -address over notched lvl rafter above dining area -uncover covered patio -uncover S3.2 10 detail connection at covered deck -address ceiling joists and hip rafter in master bed over notched -plans call for 3 2x12 above master -address over notched ceiling joist ends above master bath -roof supports not to land on 2x12’s in master bath per plans -complete bath fans vent to exterior throughout -fire block walk in closet to furr down above shower -address lvl above bed 2 over notched at bearing ends -missing hanger on double joist above front entey -address porch slab poured against sheathing -stud pack under great room Lvl at master entry -address vertical to horizontal fireblock in in basement if using Unfaced insulation it must be packed tightly and securely in place -fire block W and E furr down ends in basement -over notched stud at bed 3 W wall -anchor bolts to be in the middle 1/3 of sill plate in basement -solid block under cantilever in basement -address deck post to beam connection -complete exterior nailing to plans
All Rough Inspection - Residential Failed 7/7/2022 7/7/2022 07/07/2022
Misc
Corrective Action Required
05/27/2022
-remove covering at garage portal frame to inspect nailing to header -address ceiling joists and hip rafter in master bed over notched -roof supports not to land on 2x12’s in master bath per plans -complete bath fans vent to exterior throughout -address lvl above bed 2 over notched at bearing ends -solid block under cantilever in basement -address deck post to beam connection
All Rough Inspection - Residential Not Ready 7/13/2022 7/13/2022 07/13/2022
Misc
Corrective Action Required
07/07/2022
-address ceiling joists and hip rafter in master bed over notched(items covered) -roof supports not to land on 2x12’s in master bath per plans -complete bath fans vent to exterior throughout -address lvl above bed 2 over notched at bearing ends(covered) -solid block under cantilever in basement (covered) -address deck post to beam connection
All Rough Inspection - Residential Failed - Stop Work 7/14/2022 7/14/2022 07/14/2022
Misc
Corrective Action Required
07/13/2022
-complete bath fans vent to exterior throughout -solid block under cantilever in basement (covered) -address deck post to beam connection
Misc
Corrective Action Required
07/14/2022
drying wall being hung stop work issued.
All Rough Inspection - Residential Passed 11/29/2022 11/29/2022 11/29/2022
Misc
Resolved
11/29/2022
-complete bath fans vent to exterior throughout -solid block under cantilever in basement (covered) -address deck post to beam connection
Misc
Resolved
11/29/2022
drying wall being hung stop work issued.
Footing Inspection - Residential Passed 11/30/2022 11/30/2022
Misc
Resolved
11/30/2022
west footing wall doesnt match approved plans
Misc
Informational
11/30/2022
third party inspection performed
Driveway Inspection Partial 12/1/2022 12/1/2022 12/01/2022
Misc
Informational
12/01/2022
12-1-22 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour.
Sidewalk Inspection Partial 12/1/2022 12/1/2022 12/01/2022
Misc
Informational
12/01/2022
12-1-22 Rh. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour.
Piers/Caissons Inspection - Residential Passed 12/6/2022 12/06/2022
Misc
Informational
12/06/2022
inspection performed by third party
Occupancy Inspection - Codes Residential Ready for Temp CO 12/6/2022 12/6/2022 12/06/2022
Misc
Corrective Action Required
12/06/2022
- Sidewalk and Driveway inspections pending - final grading and sod - splash blocks - pay fees - seal all extierior penetrations
Driveway Inspection Passed 12/7/2022 12/7/2022 12/07/2022
Misc
Informational
12/01/2022
12-1-22 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour. 12-7-22 RH. Driveway meets LS and ADA specification.
Sidewalk Inspection Passed 12/7/2022 12/7/2022 12/07/2022
Misc
Informational
12/07/2022
12-1-2 RH. Sidewalk is formed up and aggregate is placed and compacted. 12-7-22 RH. Sidewalk meets LS and ADA specification.
Miscellaneous Inspection Failed 1/6/2023 01/06/2023
Misc
Informational
01/06/2023
notified walker of TCO experation and requested extension request form. permit now in NOV status. Mitchell Schwarz 01/06/2023 3:07 PM
Plot Plan Inspection Passed 01/13/2023
Erosion Control Inspection Residential Passed 01/13/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
01/13/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -maintain silt fence Mitchell Schwarz 05/27/2022 10:31 AM
Occupancy Inspection - Codes Residential Failed 1/13/2023 1/13/2023 01/13/2023
Misc
Corrective Action Required
01/13/2023
Occupancy Inspection - Codes Residential Full C of O 3/28/2023 03/28/2023
Documents & Images
Date Uploaded File Type Document Name
10/11/2021 2118 SW Red Barn Rd City Application
10/13/2021 Permit Codes Residential Plan Review
10/18/2021 Plot Plan APPROVED PLOT PLAN
10/18/2021 Approved Plans APPROVED DRAWINGS
10/18/2021 Permit Codes Residential Plan Review
10/25/2021 Permit DS Building Permit
10/25/2021 Receipt Receipt for transaction:2021-008205
10/25/2021 Letter INSPECTION SUMMARY
10/25/2021 Wilmoth 2118 SW Red Barn Ln LSMO Retreat at Hook Farms Lot 59 3rd Party Footing Inspection Report10-25-21
12/08/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/28/2021 Letter INSPECTION SUMMARY
01/21/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
07/07/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/14/2022 2118 SW Red Barn inspection letter
07/21/2022 Letter Stop Work Order
11/17/2022 Structural Letter - 2118 SW Red Barn Lane (Sept 20, 2022)
11/21/2022 2118 SW Red Barn Pier Inspection 3rd party
11/28/2022 2118 SW Red Barn 3rd party footing inspection
11/29/2022 Letter INSPECTION SUMMARY
11/30/2022 Letter INSPECTION SUMMARY
11/30/2022 LOT 59 FINAL Corrected Survey
12/01/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
12/06/2022 Letter INSPECTION SUMMARY
12/07/2022 Letter INSPECTION SUMMARY
12/07/2022 Letter INSPECTION SUMMARY
12/07/2022 Certificate/License Codes Temporary Certificate of Occupancy
12/07/2022 Receipt Receipt for transaction:2022-009351
01/06/2023 Letter Codes 10 Day Letter
01/06/2023 Letter INSPECTION SUMMARY
01/09/2023 2118 SW Red Barn Ln TCO Extension
01/13/2023 Letter INSPECTION SUMMARY
01/13/2023 Letter INSPECTION SUMMARY
01/13/2023 Letter INSPECTION SUMMARY
03/28/2023 Letter Codes Final Certificate of Occupancy
05/05/2023 Receipt Receipt for transaction:2023-002820
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: