Summary
PRRES20215017
Building Permit - Residential
Certificate of Occupancy
NEW MARK HOMES KC LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
09/24/2021
09/28/2021
07/26/2023
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
CLASS ONE ELECTRIC INC, Address:PO BOX 24343, Phone:(913) 915-1767  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
NEW MARK HOMES KC LLC, Address:5207 NW CROOKED RD  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $420.00 $420.00 Paid 09/28/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 09/28/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 09/28/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 09/28/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 09/28/2021
9110078-Valuation Fee New Single Family $1,219.70 $1,219.70 Paid 09/28/2021
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 06/30/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/15/2021 (10:30) 11/15/2021 11/15/2021
Underslab Plumbing Inspection - Residential Passed 12/27/2021 12/27/2021 12/27/2021
Erosion Control Inspection Residential Failed 1/21/2022 1/21/2022 01/21/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/21/2022
1-21-22 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -MAINTAIN SILT FENCE AT FRONT OF LOT, CLEAN DEBRIS FROM STREET, CLEAN DEBRIS FROM STORM INLET AND REPLACE GUTTER BUDDY
Piers/Caissons Inspection - Residential Failed 3/28/2022 3/28/2022 03/28/2022
Miscellaneous Correction
Corrective Action Required
03/28/2022
(3) PIERS 18 X 22 PIERS SHALL EXTEND BELOW THE FROST LINE MIN DEPTH OF 36" BELOW GRADE PER PLAN COLUMN & PIER SCHEDULE SHEET A2 : BREAK IT OF PROVIDE ENGINEERS LETTER :
Sewer Service Inspection - R Passed 4/4/2022 04/04/2022
Piers/Caissons Inspection - Residential Passed 4/7/2022 (8:00) 4/7/2022 04/07/2022
Miscellaneous Correction
Corrective Action Required
03/28/2022
(3) PIERS 18 X 22 PIERS SHALL EXTEND BELOW THE FROST LINE MIN DEPTH OF 36" BELOW GRADE PER PLAN COLUMN & PIER SCHEDULE SHEET A2 : BREAK IT OF PROVIDE ENGINEERS LETTER :
Water Service Inspection - R Partial 4/12/2022 (10:45) 4/12/2022 04/12/2022
Miscellaneous Correction
Corrective Action Required
04/12/2022
Partial, foundation to meter
Water Service Inspection - R Passed 4/13/2022 (11:00) 4/13/2022 04/13/2022
Miscellaneous Correction
Resolved
04/13/2022
Partial, foundation to meter COMPLETE
All Rough Inspection - Residential Failed 9/9/2022 9/9/2022 09/09/2022
Miscellaneous Correction
Corrective Action Required
09/09/2022
- Provide roof boot at DWV owner entry - Address over notched hip rafter north east corner dining room - Solid block sheeting breaks at bay window dining room - Nail off joist hangers in living room doubles - Complete gas connections at fire place - Support gas line at fire place - Collar ties at ridge above entry door - No support for hip rafter above laundry - Pan out switch box in return air space master bedroom - Solid block sheeting breaks master bedroom at deck - Address gap bay windows master bedroom south center - Repair broken window master bedroom - Address over notched stud basement right of north east window - Fire block top of fur out north wall basement - Provide support for soffit over 4’ wide basement - Provide clearance electrical at can light bottom of stairs - Protect electrical panel from DWV above - Flashing and trim all windows
Electrical Service Inspection Passed 9/9/2022 9/9/2022 09/09/2022
Gas Service Inspection - Residential Failed 9/9/2022 9/9/2022 09/09/2022
Misc
Corrective Action Required
09/09/2022
- fire place not connected, and or no shut off installed
Gas Service Inspection - Residential Passed 10/3/2022 10/3/2022 10/03/2022
Misc
Resolved
10/03/2022
All Rough Inspection - Residential Passed 10/3/2022 10/3/2022 10/04/2022
Miscellaneous Correction
Corrective Action Required
10/04/2022
Sidewalk Inspection Partial 10/17/2022 10/17/2022 10/17/2022
Misc
Informational
10/17/2022
Sidewalk was framed up with aggregate in and compacted. 10/17/22 ES
Driveway Inspection Partial 10/17/2022 10/17/2022 10/17/2022
Misc
Informational
10/17/2022
Driveway was framed up with aggregate in and compacted. 10/17/22 ES
Sidewalk Inspection Passed 10/21/2022 10/21/2022 10/21/2022
Misc
Informational
10/17/2022
Sidewalk was framed up with aggregate in and compacted. 10/17/22 ES Sidewalk meets LS and ADA spec. 10/21/22 ES
Driveway Inspection Passed 10/21/2022 10/21/2022 10/21/2022
Misc
Informational
10/17/2022
Driveway was framed up with aggregate in and compacted. 10/17/22 ES Driveway meets LS and ADA spec. 10/21/22 ES
Erosion Control Inspection Residential Failed 2/22/2023 02/22/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/22/2023
1-21-22 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -MAINTAIN SILT FENCE AT FRONT OF LOT, CLEAN DEBRIS FROM STREET, CLEAN DEBRIS FROM STORM INLET AND REPLACE GUTTER BUDDY
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed 6/21/2023 06/21/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/21/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/21/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Resolved
06/21/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
06/21/2023
- CLEAN STORM INLET IN FRONT OF HOUSE.
Plot Plan Inspection Passed 6/21/2023 06/21/2023
Occupancy Inspection - Codes Residential Failed 6/21/2023 6/21/2023 06/21/2023
Misc
Corrective Action Required
06/21/2023
- Obtain an irrigation permit - Label non gfci outlet at sump - Provide (2) 1/2” through bolts on each post to beam connections at deck - Center post at deck railing loose - Secure A/C whip at compressor within 12” of disconnect - Provide splash pads - Label non gfci outlet in garage
Occupancy Inspection - Codes Residential Full C of O 7/26/2023 7/26/2023 07/26/2023
Misc
Resolved
07/26/2023
Documents & Images
Date Uploaded File Type Document Name
09/24/2021 PERMIT APP_001
09/27/2021 Plans approved plans
09/27/2021 Plot Plan APPROVED PLOT PLAN
09/28/2021 Permit Codes Residential Plan Review
09/28/2021 Permit DS Building Permit
09/28/2021 Receipt Receipt for transaction:2021-007623
11/15/2021 Letter INSPECTION SUMMARY
12/27/2021 Letter INSPECTION SUMMARY
01/21/2022 Letter INSPECTION SUMMARY
03/28/2022 Letter INSPECTION SUMMARY
04/04/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
08/31/2022 Letter Codes 140 Day Letter
08/31/2022 Letter Codes 140 Day Letter
09/09/2022 Letter INSPECTION SUMMARY
09/09/2022 Letter INSPECTION SUMMARY
09/09/2022 Letter INSPECTION SUMMARY
09/15/2022 2022_09_14_Lot 101 Woodside Ridge_Apex_Notched Hip
10/03/2022 Letter INSPECTION SUMMARY
10/03/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
06/19/2023 signed as built grading lot 101
06/20/2023 Plot Plan approved as graded plot plan
06/20/2023 revised signed as built grading lot 101
06/21/2023 Letter INSPECTION SUMMARY
06/21/2023 Letter INSPECTION SUMMARY
06/21/2023 Letter INSPECTION SUMMARY
06/30/2023 Certificate/License Codes Temporary Certificate of Occupancy
06/30/2023 Receipt Receipt for transaction:2023-005083
07/26/2023 Letter Field Certificate of Occupancy
07/26/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home