Permit Application Status

PRRES20214475


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20214475
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSSES - COVERED PATIO
08/26/2021
09/01/2021
02/23/2022
08/26/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $570.00 $570.00 Paid 09/01/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 09/01/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 09/01/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 09/01/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 09/01/2021
9110078-Valuation Fee New Single Family $1,261.35 $1,261.35 Paid 09/01/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/25/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/25/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/25/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/24/2021 09/24/2021
Misc
Informational
09/24/2021
3RD PARTY FOOTING BY DEREK PEREZ AT EVERSTEAD SIGNED & SEALED BY BRADLEY HUXOL
Underslab Plumbing Inspection - Residential Passed 11/10/2021 11/10/2021 11/10/2021
Sewer Service Inspection - R Passed 1/28/2022 (9:15) 1/28/2022 01/28/2022
Water Service Inspection - R Passed 1/31/2022 01/31/2022
Erosion Control Inspection Residential Failed 3/29/2022 03/29/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/29/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE CLEAN STREET OF MUD, GRAVEL & DEBRIS
Erosion Control Inspection Residential Failed 4/18/2022 04/18/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/29/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE CLEAN STREET OF MUD, GRAVEL & DEBRIS
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/18/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER
DCM5 ESC INSP DENIED
Corrective Action Required
04/22/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. ***4/22/22 INSPECTION DENIED- CLEAN UP STREET, PROVIDE EROSION CONTROL AT PERIMETER, MAINTAIN GRAVEL FILTER TO STREET
All Rough Inspection - Residential Not Ready 4/18/2022 4/18/2022 04/18/2022
Miscellaneous Correction
Corrective Action Required
04/18/2022
NO CITY APPROVED PLANS OR TRUSS PLANS ON SITE : NO INSPECTION CORRECT THIS ITEMS RE CALL WHEN READY : THIS HOUSE IS NOT READY FOR ALL ROUGH COMPLETE SOFFITS & FURR OUTS IN GARAGE PROVIDE SCH 40 COLUMN AT GARAGE BEAM PROVIDE ANCHOR BOLTS END OF PLATE NEAR SCH 40 COLUMN IN GARAGE PROVIDE ANCHOR BOLTS SCH 40 COLUMNS BASEMENT
Erosion Control Inspection Residential Failed 04/22/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/18/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE CLEAN STREET OF MUD, GRAVEL & DEBRIS
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/18/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER
All Rough Inspection - Residential Failed 4/22/2022 4/22/2022 04/22/2022
Miscellaneous Correction
Corrective Action Required
04/18/2022
***4/22/22 INSPECTION DENIED DUE TO LACK OF EROSION CONTROL-SEE PREVIOUS FAILED EROSION CONTROL INSPECTIONS - CLEAN UP STREET, PROVIDE EROSION CONTROL AT PERIMETER, MAINTAIN GRAVEL FILTER TO STREET NO CITY APPROVED PLANS OR TRUSS PLANS ON SITE : NO INSPECTION CORRECT THIS ITEMS RE CALL WHEN READY : THIS HOUSE IS NOT READY FOR ALL ROUGH COMPLETE SOFFITS & FURR OUTS IN GARAGE PROVIDE SCH 40 COLUMN AT GARAGE BEAM PROVIDE ANCHOR BOLTS END OF PLATE NEAR SCH 40 COLUMN IN GARAGE PROVIDE ANCHOR BOLTS SCH 40 COLUMNS BASEMENT
Electrical Service Inspection Failed 4/22/2022 4/22/2022 04/22/2022
Misc
Corrective Action Required
04/22/2022
***4/22/22 INSPECTION DENIED- CLEAN UP STREET, PROVIDE EROSION CONTROL AT PERIMETER, MAINTAIN GRAVEL FILTER TO STREET
Gas Service Inspection - Residential Failed 4/22/2022 4/22/2022 04/22/2022
Misc
Corrective Action Required
04/22/2022
***4/22/22 INSPECTION DENIED- CLEAN UP STREET, PROVIDE EROSION CONTROL AT PERIMETER, MAINTAIN GRAVEL FILTER TO STREET
Gas Service Inspection - Residential Failed 5/2/2022 5/2/2022 05/02/2022
Misc
Corrective Action Required
04/22/2022
-GAS PRESSURE 0 PSI, MUST MAINTAIN 10 PSI FOR TEST
Electrical Service Inspection Passed 5/2/2022 5/2/2022 05/02/2022
Misc
Resolved
05/02/2022
***4/22/22 INSPECTION DENIED- CLEAN UP STREET, PROVIDE EROSION CONTROL AT PERIMETER, MAINTAIN GRAVEL FILTER TO STREET
All Rough Inspection - Residential Failed 5/2/2022 5/2/2022 05/02/2022
Miscellaneous Correction
Corrective Action Required
04/22/2022
-anchor bolts must be in middle third of sill plate - garage -anchor bolts required within 12” of plate breaks - see garage -protect NM within 6’ of attic entry -install all flashing boots at roof penetrations -provide full height studs at garage -Fireblock all HVAC and plumbing box outs at garage wall -fur down HVAC at garage ceiling to allow for R-19 insulation -loosen cover at garage W12x19 steel beam to verify 3” SCH 40 steel column per plans -provide (5) 2x4 stud packs at (2) 11 7/8” lvl at garage wall per plans -provide (5) 2x4 stud pack for 2nd floor girder truss bearing per plans -provide (2) 2x4 trimmer studs at garage entry door per plans -provide (2) 2x10 header and (2) trimmer studs at kitchen entry door and pantry door per plans load bearing wall -LIB bracing all locations per plans -12” oc nailing all abutting and intersecting corners -fireblock vertical to horizontal between studs at furred down soffit line garage wall, seal all penetrations on fireblock -fireblock HVAC/plumbing box out chase- see 1st floor power/great room -header off at joist cut for HVAC/plumbing box out chase great room/powder room, joist currently supported by non load bearing wall -seal all top plate penetrations - see pantry, great room -address floor joists bores for pex closer than 2" together, several joists throughout, see pantry, garage entry, kitchen, great room -secure all vertical DWV 2” or less at mid point -provide protection plates for pex above kitchen at fridge, pex span along joist less than 1 1/4” from end of joist -provide vent for kitchen sink DWV -nail all joist hangers -Provide joist hangers for joist at lvl connection great room -fireblock fireplace lid -fireblock vertical to horizontal at furred down, HVAC/plumbing chases great room -top plate to top plate lap connection as required by code, see front entry -CS-PF bracing design at home office window per plans -address top plate to top plate lap per code, 2x6 to 2x4 wall 2nd floor stairs -solid block all sheathing breaks -address top plate lap corner connection at master bed walls, different wall heights, load bearing walls -fireblock between studs at soffit line master bedroom -provide bocca protection plate at bottom plate pex master shower -fireblock at sheathing break below top plate- see master closet, 2nd floor stair wall -fireblock HVAC chase 2nd floor hall -provide (2) 2x4 trimmer studs at master bath entry per plans -provide (4) 2X stud packs at all girder truss bearing ends per plans -Provide all truss hangers per plans -provide all truss lateral bracing per plans -provide H2.5 truss hold down clips at front covered porch, covered deck, bedroom #2, master bedroom -install truss hold down structural screws per manufacturer instructions -provide min 1” clearance for b vent above furnace -address cut floor joist for HVAC above furnace basement -solid block between joists every 48” oc for kitchen island per plans -nail all exterior sheathing per plans -pan off fireplace cantilever exterior -gas pressure 0 psi, must maintain 10 psi for test
Erosion Control Inspection Residential Partial 5/2/2022 5/2/2022 05/02/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/02/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE CLEAN STREET OF MUD, GRAVEL & DEBRIS
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/02/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER
Gas Service Inspection - Residential Failed 5/11/2022 05/11/2022
Misc
Corrective Action Required
05/02/2022
-GAS PRESSURE 0 PSI, MUST MAINTAIN 10 PSI FOR TEST ( 5/11/22 0 psi not ready )
All Rough Inspection - Residential Not Ready 5/11/2022 5/11/2022 05/11/2022
Miscellaneous Correction
Corrective Action Required
05/02/2022
-anchor bolts must be in middle third of sill plate - garage -anchor bolts required within 12” of plate breaks - see garage -protect NM within 6’ of attic entry -install all flashing boots at roof penetrations -provide full height studs at garage -Fireblock all HVAC and plumbing box outs at garage wall -fur down HVAC at garage ceiling to allow for R-19 insulation -loosen cover at garage W12x19 steel beam to verify 3” SCH 40 steel column per plans -provide (5) 2x4 stud packs at (2) 11 7/8” lvl at garage wall per plans -provide (5) 2x4 stud pack for 2nd floor girder truss bearing per plans -provide (2) 2x4 trimmer studs at garage entry door per plans -provide (2) 2x10 header and (2) trimmer studs at kitchen entry door and pantry door per plans load bearing wall -LIB bracing all locations per plans -12” oc nailing all abutting and intersecting corners -fireblock vertical to horizontal between studs at furred down soffit line garage wall, seal all penetrations on fireblock -fireblock HVAC/plumbing box out chase- see 1st floor power/great room -header off at joist cut for HVAC/plumbing box out chase great room/powder room, joist currently supported by non load bearing wall -seal all top plate penetrations - see pantry, great room ( not done 5/11/22) -address floor joists bores for pex closer than 2" together, several joists throughout, see pantry, garage entry, kitchen, great room -secure all vertical DWV 2” or less at mid point -provide protection plates for pex above kitchen at fridge, pex span along joist less than 1 1/4” from end of joist -provide vent for kitchen sink DWV -nail all joist hangers -fireblock fireplace lid ( not done seal fb 5/11/22) -fireblock vertical to horizontal at furred down, HVAC/plumbing chases great room -top plate to top plate lap connection as required by code, see front entry -CS-PF bracing design at home office window per plans -address top plate to top plate lap per code, 2x6 to 2x4 wall 2nd floor stairs -solid block all sheathing breaks -address top plate lap corner connection at master bed walls, different wall heights, load bearing walls -fireblock between studs at soffit line master bedroom -provide bocca protection plate at bottom plate pex master shower -fireblock at sheathing break below top plate- see master closet, 2nd floor stair wall -fireblock HVAC chase 2nd floor hall -provide (2) 2x4 trimmer studs at master bath entry per plans -provide (4) 2X stud packs at all girder truss bearing ends per plans -Provide all truss hangers per plans -provide all truss lateral bracing per plans -provide H2.5 truss hold down clips at front covered porch, covered deck, bedroom #2, master bedroom -install truss hold down structural screws per manufacturer instructions -provide min 1” clearance for b vent above furnace ( 5/11/22 pex not ready) -address cut floor joist for HVAC above furnace basement ( not done 5/11/22) -nail all exterior sheathing per plans -pan off fireplace cantilever exterior -gas pressure 0 psi, must maintain 10 psi for test ( not ready 0 psi 5/11/22)
All Rough Inspection - Residential Failed 5/18/2022 5/18/2022 05/18/2022
Miscellaneous Correction
Corrective Action Required
05/11/2022
-protect NM within 6’ of attic entry -Fireblock all HVAC and plumbing box outs at garage wall -LIB bracing all locations per plans -fireblock HVAC/plumbing box out chase- see 1st floor power/great room -header off at joist cut for HVAC/plumbing box out chase great room/powder room, joist currently supported by non load bearing wall -provide protection plates for pex above kitchen at fridge, pex span along joist less than 1 1/4” from end of joist -provide vent for kitchen sink DWV -solid block all sheathing breaks -gas pressure 5 psi, must maintain 10 psi for test ( not ready 5 psi 5/18/22)
Gas Service Inspection - Residential Failed 5/18/2022 5/18/2022 05/18/2022
Misc
Corrective Action Required
05/11/2022
-GAS PRESSURE 5 PSI, MUST MAINTAIN 10 PSI FOR TEST ( 5/18/22 0 psi not ready )
Gas Service Inspection - Residential Failed 5/23/2022 5/23/2022 05/23/2022
Misc
Corrective Action Required
05/18/2022
-GAS PRESSURE 5 PSI, MUST MAINTAIN 10 PSI FOR TEST ( 5/18/22 0 psi not ready ) Shawn Hoffman 05/23/2022 8:56 AM ONLY 6 LB
All Rough Inspection - Residential Not Ready 5/24/2022 5/24/2022 05/24/2022
Miscellaneous Correction
Corrective Action Required
05/18/2022
-protect NM within 6’ of attic entry -Fireblock all HVAC and plumbing box outs at garage wall -fireblock HVAC/plumbing box out chase- see 1st floor power/great room -header off at joist cut for HVAC/plumbing box out chase great room/powder room, joist currently supported by non load bearing wall -provide protection plates for pex above kitchen at fridge, pex span along joist less than 1 1/4” from end of joist -solid block all sheathing breaks (home insulated could not inspect)
Gas Service Inspection - Residential Passed 5/24/2022 5/24/2022 05/24/2022
Misc
Resolved
05/24/2022
-GAS PRESSURE 5 PSI, MUST MAINTAIN 10 PSI FOR TEST ( 5/18/22 0 psi not ready ) Shawn Hoffman 05/23/2022 8:56 AM ONLY 6 LB
All Rough Inspection - Residential Passed 5/25/2022 5/25/2022 05/25/2022
Miscellaneous Correction
Resolved
05/25/2022
Driveway Inspection Partial 6/14/2022 6/14/2022 06/14/2022
Misc
Informational
06/14/2022
Driveway was framed up with aggregate in and compacted. Had one small section of curbing that needed patched as well. 6/14/22 ES
Driveway Inspection Passed 6/20/2022 6/20/2022 06/22/2022
Misc
Informational
06/14/2022
Driveway was framed up with aggregate in and compacted. Had one small section of curbing that needed patched as well. 6/14/22 ES Driveway meets LS and ADA specs. 6/22/22 ES
Sidewalk Inspection Partial 8/4/2022 8/4/2022 08/04/2022
Misc
Informational
08/04/2022
Sidewalk was framed up with aggregate in and compacted. 8/4/22 ES
Sidewalk Inspection Passed 8/12/2022 8/12/2022 08/17/2022
Misc
Informational
08/04/2022
Sidewalk was framed up with aggregate in and compacted. 8/4/22 ES Sidewalk meets LS and ADA spec. 8/17/22 ES
Piers/Caissons Inspection - Residential Passed 08/24/2022
Misc
Informational
08/24/2022
INSPECTED BY THIRD PARTY. EVERSTEAD AT TIME OF FOOTING.
Erosion Control Inspection Residential Passed 8/24/2022 08/24/2022
Occupancy Inspection - Codes Residential Failed 8/24/2022 8/24/2022 08/24/2022
Misc
Corrective Action Required
08/24/2022
NO ACCESS, BUILDER AWARE.
Occupancy Inspection - Codes Residential Failed 8/25/2022 8/25/2022 08/25/2022
Misc
Corrective Action Required
08/24/2022
-Final grade, sod, splash blockss, sump extension -Shut off for exterior gas appliance to be within 6' -Fireblock dead space at exterior fireplace -Stair risers to basement to be no greater than 7 3/4" and vary no more than 3/8" -Provide 1" clearance to combustibles at furnace B vent
Plot Plan Inspection Passed 8/26/2022 08/26/2022
Occupancy Inspection - Codes Residential Full C of O 8/26/2022 8/26/2022 08/26/2022
Misc
Resolved
08/26/2022
Documents & Images
Date Uploaded File Type Document Name
08/26/2021 W2 #48 - Permit App
08/26/2021 LOT 48 FINAL
08/27/2021 Approved Plans APPROVED PLANS
08/27/2021 Approved Plans APPROVED TRUSS LAYOUT
08/27/2021 Approved Plans APPROVED TRUSS PACKAGE
08/27/2021 Permit Codes Residential Plan Review
09/01/2021 Plot Plan APPROVED PLOT PLAN
09/01/2021 Permit Codes Residential Plan Review
09/01/2021 Permit DS Building Permit
09/01/2021 Receipt Receipt for transaction:2021-007056
09/24/2021 48 Woodside Ridge FTNG
09/24/2021 Letter INSPECTION SUMMARY
11/10/2021 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
01/31/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
04/18/2022 Letter INSPECTION SUMMARY
04/18/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
05/02/2022 Letter INSPECTION SUMMARY
05/02/2022 Letter INSPECTION SUMMARY
05/02/2022 Letter INSPECTION SUMMARY
05/02/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/18/2022 Letter INSPECTION SUMMARY
05/18/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/25/2022 Letter INSPECTION SUMMARY
05/25/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
08/04/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
08/24/2022 Letter INSPECTION SUMMARY
08/24/2022 Letter INSPECTION SUMMARY
08/24/2022 Letter INSPECTION SUMMARY
08/25/2022 Receipt Receipt for transaction:2022-006981
08/25/2022 Letter INSPECTION SUMMARY
08/25/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
08/26/2022 Letter INSPECTION SUMMARY
08/26/2022 Letter Field Certificate of Occupancy
08/26/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home