Permit Application Status

PRRES20214078


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20214078
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE. COVERED PATIO. UNFINISHED BASEMENT.
08/05/2021
08/31/2021
02/06/2022
09/08/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
UNITED PLUMBING & SERVICE CO INC, Address:301 DUCK RD, Phone:(816) 761-5262  
AJ@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $570.00 $570.00 Paid 08/31/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 08/31/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 08/31/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 08/31/2021
9110078-Valuation Fee New Single Family $1,350.41 $1,350.41 Paid 08/31/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/31/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/07/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/20/2021 10/20/2021 10/20/2021
Underslab Plumbing Inspection - Residential Failed 10/20/2021 10/20/2021 10/20/2021
Misc
Corrective Action Required
10/20/2021
*NO address posted* -Complete Drain tile
Underslab Plumbing Inspection - Residential Passed 10/22/2021 10/22/2021 10/22/2021
Misc
Resolved
10/22/2021
Erosion Control Inspection Residential Failed 10/22/2021 10/22/2021 10/22/2021
Misc
Corrective Action Required
10/22/2021
Repair downed silt fence.
Sewer Service Inspection - R Passed 12/27/2021 12/27/2021
Water Service Inspection - R Passed 12/29/2021 (1:00) 12/29/2021 12/29/2021
Erosion Control Inspection Residential Failed 12/29/2021 12/29/2021 12/29/2021
Misc
Resolved
12/29/2021
Repair downed silt fence.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/29/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Erosion Control Inspection Residential Failed 3/8/2022 3/8/2022 03/08/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/29/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. ADDRESS EROSION CONTROL ON LOT GRAVEL FILTER REQUIRED, MIN 6" LIFT 3/4" GRAVEL CLEAN ALL MUD FROM STREET
Gas Service Inspection - Residential Failed 4/5/2022 4/5/2022 04/05/2022
Miscellaneous Correction
Corrective Action Required
04/05/2022
All rough not ready
Electrical Service Inspection Failed 4/5/2022 4/5/2022 04/05/2022
Miscellaneous Correction
Corrective Action Required
04/05/2022
All rough not ready
All Rough Inspection - Residential Not Ready 4/5/2022 4/5/2022 04/05/2022
Miscellaneous Correction
Corrective Action Required
04/05/2022
4/5/22 ** HOUSE IS NOT READY FOR INSPECTION, THIS LIST WAS MADE FOR THE GARAGE ONLY. AND WILL CHANGE. CORRECT THESE ITEMS BEFORE RESCHEDULING: -Address exterior wall not connected at top plates at beam -Provide attic access in 2 car bay -Address exterior load bearing walls not connected at top plates at single bay and return panel -No top plate under GT at single car bay and H2.5 not installed properly -Exterior sheathing not nailed to top plate at single car return panel -Nail all exterior corners and intersecting walls per code -Complete fur down for mechanical on cantilever side of beam -Pan off dwv/ hvac chase with approved fireblocking materials- insulation is not approved to be used in this manner -Use approved fireblocking materials at soffit line in garage-Tyvek and smart siding are not approved materials -Pan off back of fur out wall in garage to separate from soffit space -Nail LIB to sole plate in garage -(2) nails at all framing members at all LIB -Missing LIB in powder room, great room -(3) 2x4 under LVL in back garage bearing wall -(2) 2x4 under double 2x12 in back garage wall -(4) studs at GT bearing locations -Provide roof ventilation at double car bay
Electrical Service Inspection Passed 4/7/2022 4/7/2022 04/07/2022
Miscellaneous Correction
Resolved
04/07/2022
All rough not ready
Gas Service Inspection - Residential Passed 4/7/2022 4/7/2022 04/07/2022
Miscellaneous Correction
Resolved
04/07/2022
All rough not ready
All Rough Inspection - Residential Failed 4/7/2022 4/7/2022 04/07/2022
Miscellaneous Correction
Corrective Action Required
04/05/2022
-Pan off dwv/ hvac chase with approved fireblocking materials -Use approved fireblocking materials at soffit line in garage-SEAL PENETRATIONS -Pan off back of fur out wall in garage to separate from soffit space-SEAL PENETRATIONS -Missing LIB in Bed 1/great room-NOT COMPLETE -(3) 2x4 under LVL in back garage bearing wall-NOT COMPLETE -(2) 2x4 under double 2x12 in back garage wall -NOT COMPLETE -(4) studs at GT bearing locations-NOT COMPLETE-SEE GARAGE WALL, HOME OFFICE,GREAT ROOM, BATH 2 -Complete electrical for whirlpool tub *motor and electrical to be accessible as well -Load bearing wall top plate lapped less than 24” at master tub -Seal top plate penetration at master bed exterior wall -(4) 2x6 studs under beam at fireplace -Protect NM at header in great less than 1.25” to face of stud -Support ridge beam at covered deck -Provide ridge straps or collar ties at rafters at covered deck -Brace 2x12 beam at covered deck East side to wall to prevent rotation - Strap exterior wall at SGD to adjacent wall at top plates -Fireblock top of wall from truss space by refrigerator -(4) 2x4 under LVL at office closet -Nail snow blocking bed 4 throughout -Address exterior walls not connected at top plates bed 2 -Fireblock and seal gaps and penetrations at wall to truss space between bed 2/3 with approved materials -Fireblock top wall at stairwell trusses
All Rough Inspection - Residential Failed 4/14/2022 4/14/2022 04/14/2022
Miscellaneous Correction
Corrective Action Required
04/07/2022
-Pan off dwv/ hvac chase with approved fireblocking materials -Use approved fireblocking materials at soffit line in garage-SEAL PENETRATIONS -Brace 2x12 beam at covered deck East side to wall to prevent rotation - -Address exterior walls not connected at top plates bed 2 **REPLACE STUDS ADDED FOR STUD PACKS AT LOCATIONS BELOW, ADDED STUDS TURNED DIFFERENT DIRECTIONS AND OVERNOTCHED AROUND ELECTRICAL, CAN ONLY NOTCH 25% OF STUD WIDTH ON LOAD BEARING STUD** -(3) 2x4 under LVL in back garage bearing wall -(2) 2x4 under double 2x12 in back garage wall -(4) studs at GT bearing locations-NOT COMPLETE-SEE GARAGE WALL, HOME OFFICE,GREAT ROOM, BATH 2 ok to insulate
Erosion Control Inspection Residential Partial 4/14/2022 4/14/2022 04/14/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/14/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. ADDRESS EROSION CONTROL ON LOT GRAVEL FILTER REQUIRED, MIN 6" LIFT 3/4" GRAVEL CLEAN ALL MUD FROM STREET
All Rough Inspection - Residential Passed 4/21/2022 4/21/2022 04/21/2022
Miscellaneous Correction
Resolved
04/21/2022
Driveway Inspection Partial 6/10/2022 6/10/2022 06/10/2022
Misc
Informational
06/10/2022
On 6.10.2022 I performed a driveway inspection and pass the subgrade to pour concrete.
Sidewalk Inspection Partial 6/10/2022 6/10/2022 06/10/2022
Misc
Informational
06/10/2022
On 6.10.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete.
Erosion Control Inspection Residential Passed 08/30/2022
Plot Plan Inspection Passed 08/30/2022
Occupancy Inspection - Codes Residential Failed 8/30/2022 8/30/2022 08/30/2022
Misc
Corrective Action Required
08/30/2022
-Sidewalk and Driveway inspections pending -Pay all outstanding fees -Address basement stair risers greater than 7.75" -Label non GFCI receptacel at panel -Provide 1" clearance to electrical conduit at furnace b vent -Foundation drainage to extend 36" -Seal patch in siding at west receptacle -Seal exterior penetrations and top of meter can at east
Driveway Inspection Passed 09/08/2022
Misc
Informational
06/10/2022
On 6.10.2022 I performed a driveway inspection and pass the subgrade to pour concrete. 9-8-22 RH. Driveway meets LS and ADA specification.
Sidewalk Inspection Passed 09/08/2022
Misc
Informational
06/10/2022
On 6.10.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete. 9-8-22 RH. Sidewalk meets LS and ADA specification.
Occupancy Inspection - Codes Residential Full C of O 9/8/2022 9/8/2022 09/08/2022
Misc
Resolved
09/08/2022
Documents & Images
Date Uploaded File Type Document Name
08/05/2021 RR #68 - PERMIT APP
08/09/2021 Approved Plans APPROVED DRAWINGS
08/10/2021 Permit Codes Residential Plan Review
08/12/2021 Plot Plan APPROVED PLOT PLAN
08/12/2021 Approved Plans APPROVED TRUSS LAYOUT
08/31/2021 Approved Plans APPROVED TRUSS PACKAGE
08/31/2021 Permit Codes Residential Plan Review
08/31/2021 Permit DS Building Permit
08/31/2021 Receipt Receipt for transaction:2021-006990
10/19/2021 68 Reserve at Stoney Creek FDTN
10/19/2021 68 Reserve at Stoney Creek FTNG
10/20/2021 Letter INSPECTION SUMMARY
10/20/2021 Letter INSPECTION SUMMARY
10/22/2021 Letter INSPECTION SUMMARY
10/22/2021 Letter INSPECTION SUMMARY
12/27/2021 Letter INSPECTION SUMMARY
12/29/2021 Letter INSPECTION SUMMARY
12/29/2021 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
04/21/2022 Letter INSPECTION SUMMARY
06/10/2022 Letter INSPECTION SUMMARY
06/10/2022 Letter INSPECTION SUMMARY
08/30/2022 Letter INSPECTION SUMMARY
08/30/2022 Letter INSPECTION SUMMARY
08/30/2022 Letter INSPECTION SUMMARY
09/07/2022 Receipt Receipt for transaction:2022-007346
09/08/2022 Letter INSPECTION SUMMARY
09/08/2022 Letter INSPECTION SUMMARY
09/08/2022 Letter Field Certificate of Occupancy
09/08/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home