Permit Application Status

PRRES20214073


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20214073
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
08/05/2021
08/24/2021
02/05/2022
09/01/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $360.00 $360.00 Paid 08/24/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/24/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/24/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 08/24/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 08/24/2021
9110078-Valuation Fee New Single Family $1,015.38 $1,015.38 Paid 08/24/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/11/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/12/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/26/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/22/2021 (11:15) 9/22/2021 09/22/2021
Misc
Informational
09/22/2021
UFER LOCATED SOUTH FOUNDATION WALL GARAGE POURING 2 PADS AT COVERED DECK NOT 36" DEEP PIERS
Sewer Service Inspection - R Passed 11/30/2021 (8:00) 11/30/2021 11/30/2021
Water Service Inspection - R Passed 12/1/2021 (9:15) 12/1/2021 12/01/2021
Underslab Plumbing Inspection - Residential Passed 12/1/2021 12/1/2021 12/01/2021
Electrical Service Inspection Passed 4/25/2022 4/25/2022 04/25/2022
Gas Service Inspection - Residential Failed 4/25/2022 4/25/2022 04/25/2022
Misc
Corrective Action Required
04/25/2022
-Gas pressure at 1 psi, must maintain 10 psi for test
All Rough Inspection - Residential Failed 4/25/2022 4/25/2022 04/25/2022
Misc
Corrective Action Required
04/25/2022
-maintain gravel filter on drive -nail exterior sheathing per plans -provide flashing above exterior window trim -fire rating required at eaves projection per R302.1(1) - see above electrical home run, covered deck, covered porch -fire rating required of exterior walls required per R302.1(1) - exterior layer pyro guard sheathing observed at all rough -nail all truss hangers -provide H2.5 hold downs or equivalent at all hip trusses -provide H2.5 hold downs or equivalent at all trusses covered deck and covered porch, trusses at front entry, front bedroom -provide all truss hangers per plans -provide all truss lateral bracing per plans -30” vertical clearance required at attic access -anchor bolt shall be in middle third of sill plate at garage portal -Fireblock deadspace at master water closet -complete fireplace vent to exterior roof -nail all intersecting corners 12” oc -solid block all sheathing breaks -Fireblock deadspace kitchen left of fridge -fireblock deadspace box out stair wall -fireblock at top plate between furring strips at tub front bath 1st floor -provide full bearing for covered porch dbl beam at front bedroom -min 24” lap between dbl top plate breaks - see front bedroom -provide (4) 2X douglas fir #2 stud packs at all girder truss bearing points per plans -provide exterior bracing design CS-PF at master bedroom windows per plans -address steel beam projection into basement stairway -nail all joist hangers basement -anchor all SCH 40 steel columns to floor at basement -fur down at HVAC duct finished basement den -provide anchor bolts within 12” of plate break basement -sister 2x6 studs to exterior wall studs that have been overnotched around anchor bolts at basement -shield service panel from DWV waste line above panel -solid block between joists above bream, lateral restraint, basement mechanical -fur down at plumbing basement bed hall -address floor joist overbored for DWV at basement unfinished storage -anchor bottom plates to floor basement -complete pex water line above basement bedroom closet -fireblock vertical every 10’ between studs and foundation/framing at finished basement, see den -solid block between joists every 48” oc for kitchen island per plans -provide joist hangers at joist to dbl rim connection above basement bedroom egress window -Gas pressure 1 psi must maintain 10 psi for tes
Erosion Control Inspection Residential Failed 4/25/2022 4/25/2022 04/25/2022
Misc
Corrective Action Required
04/25/2022
-Maintain gravel filter on drive
Gas Service Inspection - Residential Passed 4/29/2022 4/29/2022 04/29/2022
Misc
Resolved
04/29/2022
-Gas pressure at 1 psi, must maintain 10 psi for test
All Rough Inspection - Residential Failed 4/29/2022 4/29/2022 04/29/2022
Misc
Corrective Action Required
04/25/2022
-provide flashing above exterior window trim -fire rating required of exterior walls required per R302.1(1) - exterior layer pyro guard sheathing observed at all rough -nail off all truss hangers -anchor bolt shall be in middle third of sill plate at garage portal, tighten anchor bolt -land electrical to box at front bedroom wall -provide (4) 2X douglas fir #2 stud packs at all girder truss bearing points per plans -provide exterior bracing design CS-PF at master bedroom windows per plans, nail exterior sheathing per design -anchor all SCH 40 steel columns to floor at basement, see mechanical -address floor joist overbored for DWV at basement unfinished storage, Have engineer address if field fix is acceptable -solid block between joists every 48” oc for kitchen island per plans
Erosion Control Inspection Residential Failed 4/29/2022 4/29/2022 04/29/2022
Misc
Corrective Action Required
04/25/2022
-Maintain gravel filter on drive
All Rough Inspection - Residential Not Ready 5/9/2022 5/9/2022 05/09/2022
Misc
Corrective Action Required
04/29/2022
-provide flashing above exterior window trim -fire rating required of exterior walls required per R302.1(1) - exterior layer pyro guard sheathing observed at all rough REMOVE VENT & REPAIR SOFFIT ABOVE METER CAN -provide (4) 2X douglas fir #2 stud packs at all girder truss bearing points per plans GARAGE & FIREPLACE
All Rough Inspection - Residential Not Ready 5/11/2022 5/11/2022 05/11/2022
Misc
Corrective Action Required
05/09/2022
-fire rating required of exterior walls required per R302.1(1) - exterior layer pyro guard sheathing observed at all rough (Require screw inspection rated assembly) -provide (4) 2X douglas fir #2 stud packs at all girder truss bearing points per plans GARAGE & FIREPLACE ( not done 5/11/22)
All Rough Inspection - Residential Partial 5/13/2022 5/13/2022 05/13/2022
Misc
Corrective Action Required
05/11/2022
-fire rating required of exterior walls required per R302.1(1) - exterior layer pyro guard sheathing observed at all rough (Require screw inspection rated assembly)
Rated Assembly Inspection Passed 5/24/2022 5/24/2022 05/24/2022
All Rough Inspection - Residential Passed 5/27/2022 5/27/2022 05/27/2022
Misc
Resolved
05/27/2022
-fire rating required of exterior walls required per R302.1(1) - exterior layer pyro guard sheathing observed at all rough (Require screw inspection rated assembly)
Driveway Inspection Partial 6/2/2022 6/2/2022 06/02/2022
Misc
Informational
06/02/2022
Driveway was framed up with aggregate in and compacted. 6/2/22 ES
Driveway Inspection Passed 6/10/2022 6/10/2022 06/20/2022
Misc
Informational
06/02/2022
Driveway was framed up with aggregate in and compacted. 6/2/22 ES Driveway meets LS spec. 6/20/22 ES
Erosion Control Inspection Residential Passed 08/23/2022
Misc
Resolved
08/23/2022
Occupancy Inspection - Codes Residential Failed 8/23/2022 8/23/2022 08/23/2022
Misc
Corrective Action Required
08/23/2022
Provide gutters and down spouts Remove dirt from water meter pit and add gravel in bottom Single outlet in laundry mark non gfci Uncover smoke detectors Complete gas service Garage door must be self closing and latch
Plot Plan Inspection Passed 08/23/2022
Occupancy Inspection - Codes Residential Ready for Temp CO 8/26/2022 8/26/2022 08/26/2022
Misc
Corrective Action Required
08/23/2022
--Remove dirt from water meter pit and add gravel in bottom -Addess to be contrasting color -paint gas piping outside
Occupancy Inspection - Codes Residential Temporary C of O 08/26/2022
Misc
Corrective Action Required
08/26/2022
--Remove dirt from water meter pit and add gravel in bottom -Addess to be contrasting color -paint gas piping outside
Occupancy Inspection - Codes Residential Full C of O 9/1/2022 9/1/2022 09/01/2022
Misc
Resolved
09/01/2022
Documents & Images
Date Uploaded File Type Document Name
08/05/2021 Approved Plans APPROVED TRUSS DRAWINGS
08/05/2021 Approved Plans APPROVED TRUSS LAYOUT
08/05/2021 Plot Plan APPROVED PLOT PLAN
08/05/2021 Permit Codes Residential Plan Review
08/05/2021 W1 #33 - Permit App
08/09/2021 Plot Plan APPROVED PLOT PLAN
08/09/2021 Permit Codes Residential Plan Review
08/23/2021 W1 #33 - REVISEDMilan - Mediterranean - Sheets- signed
08/23/2021 Approved Plans APPROVED PLANS
08/24/2021 Permit Codes Residential Plan Review
08/24/2021 Permit DS Building Permit
08/24/2021 Receipt Receipt for transaction:2021-006771
09/22/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
12/01/2021 Letter INSPECTION SUMMARY
12/01/2021 Letter INSPECTION SUMMARY
12/17/2021 w1 #33 - Scope of Work Statement Application
12/17/2021 Approved Plans APPROVED BASEMENT FINISH
12/17/2021 Letter DS Building Permit
04/20/2022 Letter Codes 140 Day Letter
04/25/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
05/07/2022 W1 33 Joist Engineer Letter
05/09/2022 Letter INSPECTION SUMMARY
05/11/2022 Receipt Receipt for transaction:2022-003210
05/11/2022 Letter INSPECTION SUMMARY
05/12/2022 Receipt Receipt for transaction:2022-003303
05/13/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
06/02/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
08/23/2022 Letter INSPECTION SUMMARY
08/23/2022 Letter INSPECTION SUMMARY
08/23/2022 Letter INSPECTION SUMMARY
08/26/2022 Receipt Receipt for transaction:2022-007030
08/26/2022 Letter Codes Temporary Certificate of Occupancy
09/01/2022 Letter Field Certificate of Occupancy
09/01/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home