Permit Application Status

PRRES20213908


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213908
Building Permit - Residential
Certificate of Occupancy
WYSS HOME BUILDING LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY HOME. WALKOUT. COVERED PORCH. RETAINING WALL IN BACK DONE BY HOMEOWNER WITH BUILDER APPROVAL.
07/28/2021
08/10/2021
01/30/2022
03/06/2024
Locations
Contacts
WYSS HOME BUILDING LLC, Address:PO BOX 6620, Phone:(816) 820-0142  
WYSS HOME BUILDING LLC, Address:PO BOX 6620, Phone:(816) 820-0142  
Max Wyss, Address:PO Box 6620 , Phone:(816) 820-0142  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
ROBERTSON PLUMBING LLC, Address:PO BOX 165, Phone:(816) 781-9340  
mcrwyss@yahoo.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $750.00 $750.00 Paid 08/10/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 08/10/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 08/10/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/10/2021
9110078-Valuation Fee New Single Family $1,497.17 $1,497.17 Paid 08/10/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/10/2021
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 11/15/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 11/19/2021 11/19/2021 11/19/2021
Misc
Corrective Action Required
11/19/2021
-uncover drain tile for inspection -uncover covered dwv exiting foundation
Underslab Plumbing Inspection - Residential Passed 11/22/2021 11/22/2021 11/22/2021
Misc
Corrective Action Required
11/19/2021
-uncover drain tile for inspection -uncover covered dwv exiting foundation
Suspended Slab Inspection Passed 1/24/2022 (10:00) 1/24/2022 01/24/2022
Piers/Caissons Inspection - Residential Failed 1/24/2022 (10:00) 1/24/2022 01/24/2022
Misc
Corrective Action Required
01/24/2022
-PROVIDE REVISED PLANS SHOWING NEW PIER LOCATION AND DETAILS
Erosion Control Inspection Residential Failed 2/8/2022 2/8/2022 02/08/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/08/2022
**2-8-22 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/08/2022
**2-8-22 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM3 ESC REQUIRED 2 DAY
Resolved
02/08/2022
.
Erosion Control Inspection Residential Partial 2/11/2022 2/11/2022 02/11/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
02/11/2022
**2-8-22 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM3 ESC REQUIRED 2 DAY
Resolved
02/11/2022
**2-8-22 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed 3/16/2022 03/16/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/16/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Maintain gravel filter -clean up street
Erosion Control Inspection Residential Failed 3/28/2022 03/28/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/16/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Maintain gravel filter -clean up street -fix downed silt fence
Sewer Service Inspection - R Passed 3/28/2022 (11:00) 3/28/2022 03/28/2022
Water Service Inspection - R Passed 3/28/2022 (11:00) 3/28/2022 03/28/2022
Erosion Control Inspection Residential Failed 7/8/2022 07/08/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/28/2022
EROSION CONTROL REQUIRED. - address tall vegetation on lot. -clean up street -fix downed silt fence
All Rough Inspection - Residential Failed 7/8/2022 7/8/2022 07/08/2022
Miscellaneous Correction
Corrective Action Required
07/08/2022
Anchor bolts to be in middle third of plate garage west side Security blocking at deck doors Strap DWV 2” and under vertical through out Fire block nm penetration master shower Missing hanger dressing room rafter Provide ladder for inspection of covered deck, or uncover Address over notched studs basement near electrical panel Provide 1” clearance at B vent in attic space
Electrical Service Inspection Passed 7/8/2022 7/8/2022 07/08/2022
Gas Service Inspection - Residential Failed 7/8/2022 7/8/2022 07/08/2022
Miscellaneous Correction
Corrective Action Required
07/08/2022
Minimum of 10 psi for inspection, only 7 psi at time of inspection
All Rough Inspection - Residential Passed 7/12/2022 07/12/2022
Miscellaneous Correction
Resolved
07/12/2022
Anchor bolts to be in middle third of plate garage west side Security blocking at deck doors Strap DWV 2” and under vertical through out Fire block nm penetration master shower Missing hanger dressing room rafter Provide ladder for inspection of covered deck, or uncover Address over notched studs basement near electrical panel Provide 1” clearance at B vent in attic space
Gas Service Inspection - Residential Passed 7/12/2022 07/12/2022
Miscellaneous Correction
Resolved
07/12/2022
Minimum of 10 psi for inspection, only 7 psi at time of inspection
Driveway Inspection Partial 9/29/2022 (1:00) 9/29/2022 09/29/2022
Misc
Informational
09/29/2022
9-29-22 RH. Driveway is formed up and aggregate is placed and compacted.
Sidewalk Inspection Partial 9/30/2022 9/30/2022 09/30/2022
Misc
Informational
09/30/2022
9-30-22 RH. Sidewalk was formed up and aggregate was placed and compacted.
Sidewalk Inspection Partial 10/3/2022 10/3/2022 10/03/2022
Misc
Informational
09/30/2022
9-30-22 RH. Sidewalk was formed up and aggregate was placed and compacted. 10-3-22 RH. Sidewalk on side of house is formed up and aggregate is placed and compacted.
Driveway Inspection Passed 10/6/2022 10/6/2022 10/06/2022
Misc
Informational
09/29/2022
9-29-22 RH. Driveway is formed up and aggregate is placed and compacted. 10-6-22 RH. Driveway meets LS and ADA specification.
Sidewalk Inspection Passed 10/10/2022 10/10/2022 10/06/2022
Misc
Informational
10/03/2022
9-30-22 RH. Sidewalk was formed up and aggregate was placed and compacted. 10-3-22 RH. Sidewalk on side of house is formed up and aggregate is placed and compacted. 10-6-22 RH. Sidewalk meets LS and ADA specification.
Retaining Wall Inspection Passed 10/21/2022 10/21/2022
Plot Plan Inspection Passed 10/21/2022 10/21/2022
Erosion Control Inspection Residential Passed 11/14/2022 11/14/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
11/14/2022
EROSION CONTROL REQUIRED. - address tall vegetation on lot. -clean up street -fix downed silt fence
Occupancy Inspection - Codes Residential Failed 11/14/2022 11/14/2022 11/14/2022
Misc
Corrective Action Required
11/14/2022
-address pending footing inspection -address pier inspection not passed -obtain lawn irrigation permit -gutters to be installed -cap off open dwv in garage -anti syphon device at water in basement -address siding from grade at rear of home multiple areas -tamper caps at A/c unit
Footing Inspection - Residential Passed 11/15/2022 11/15/2022
Piers/Caissons Inspection - Residential Passed 11/15/2022 11/15/2022
Misc
Resolved
11/15/2022
-PROVIDE REVISED PLANS SHOWING NEW PIER LOCATION AND DETAILS
Occupancy Inspection - Codes Residential Ready for Temp CO 11/15/2022 11/15/2022 11/15/2022
Misc
Resolved
03/07/2024
-obtain lawn irrigation permit and complete -gutters to be installed -address siding from grade at rear of home multiple areas -tamper caps at A/c unit
Occupancy Inspection - Codes Residential Failed 12/15/2022 12/15/2022
Misc
Corrective Action Required
11/15/2022
-obtain lawn irrigation permit and complete -gutters to be installed -address siding from grade at rear of home multiple areas -tamper caps at A/c unit
Occupancy Inspection - Codes Residential Full C of O 3/6/2024 03/06/2024
Misc
Resolved
03/06/2024
-obtain lawn irrigation permit and complete -gutters to be installed -address siding from grade at rear of home multiple areas -tamper caps at A/c unit
Documents & Images
Date Uploaded File Type Document Name
08/03/2021 Scope of Work SCOPE OF WORK
08/03/2021 Permit Codes Residential Plan Review
08/09/2021 License_Tax_Application 1
08/10/2021 Approved Plans APPROVED DRAWINGS
08/10/2021 Plot Plan APPROVED PLOT PLAN
08/10/2021 Permit Codes Residential Plan Review
08/10/2021 Permit DS Building Permit
08/10/2021 Receipt Receipt for transaction: 2021-006381
11/19/2021 Letter INSPECTION SUMMARY
11/22/2021 Letter INSPECTION SUMMARY
01/24/2022 Letter INSPECTION SUMMARY
01/24/2022 Letter INSPECTION SUMMARY
02/08/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/28/2022 Letter INSPECTION SUMMARY
03/28/2022 Letter INSPECTION SUMMARY
03/28/2022 Letter INSPECTION SUMMARY
07/08/2022 Letter INSPECTION SUMMARY
07/08/2022 Letter INSPECTION SUMMARY
07/08/2022 Letter INSPECTION SUMMARY
07/08/2022 Letter INSPECTION SUMMARY
07/12/2022 Letter INSPECTION SUMMARY
07/12/2022 Letter INSPECTION SUMMARY
07/18/2022 Plans RETAINING WALL PLANS
07/18/2022 Email Memo Style
09/29/2022 Letter INSPECTION SUMMARY
09/30/2022 Letter INSPECTION SUMMARY
10/03/2022 Letter INSPECTION SUMMARY
10/06/2022 Letter INSPECTION SUMMARY
10/06/2022 Letter INSPECTION SUMMARY
10/20/2022 Plot Plan APPROVED AS BUILT PLOT PLAN
10/21/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
11/14/2022 Letter INSPECTION SUMMARY
11/14/2022 74 Summit View Farms FDTN
11/14/2022 74 Summit View Farms FTNG
11/14/2022 DW Permit Plan New Plan 21-033R Lot 74 SVF 2317 SW Chase Cir 10-27-22
11/15/2022 Letter INSPECTION SUMMARY
11/15/2022 Letter INSPECTION SUMMARY
11/15/2022 Certificate/License Codes Temporary Certificate of Occupancy
11/15/2022 Receipt Receipt for transaction:2022-008932
12/15/2022 Letter Codes 10 Day Letter
03/06/2024 Letter INSPECTION SUMMARY
03/06/2024 Letter INSPECTION SUMMARY
03/06/2024 Letter Field Certificate of Occupancy
03/06/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home