Permit Application Status

PRRES20213813


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213813
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. COVERED DECK. FINISHED/UNFINISHED BASEMENT. WALKOUT.
07/22/2021
09/01/2021
08/04/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JOE@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 09/01/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 09/01/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 09/01/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 09/01/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 09/01/2021
9110078-Valuation Fee New Single Family $947.33 $947.33 Paid 09/01/2021
8331504-EFHB Middle Big Creek, Full $401.76 $401.76 Paid 10/22/2021
9110078-Valuation Fee New Single Family $47.68 $47.68 Paid 11/23/2021
$995.01
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/14/2021 10/14/2021 10/14/2021
Misc
Informational
10/14/2021
APPROVED PER DAVID P AINSWORTH 10/6/21
Underslab Plumbing Inspection - Residential Passed 11/3/2021 11/3/2021 11/03/2021
Sewer Service Inspection - R Passed 12/6/2021 (8:45) 12/6/2021 12/06/2021
Water Service Inspection - R Passed 12/9/2021 (11:30) 12/9/2021 12/09/2021
Erosion Control Inspection Residential Failed 12/9/2021 12/9/2021 12/09/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/09/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Passed 3/23/2022 3/23/2022 03/23/2022
Gas Service Inspection - Residential Failed 3/23/2022 3/23/2022 03/23/2022
Misc
Corrective Action Required
03/23/2022
**GAS LINE BOND REQUIRED** PRESSURE OK
All Rough Inspection - Residential Failed 3/23/2022 3/23/2022 03/23/2022
Misc
Corrective Action Required
03/23/2022
-security blocking at deck door -solid shim at hinges deck door -install all missing windows -fireblock tub traps -provide full bearing for beam at front bedroom wall from covered porch, shim to studs below -CS-PF bracing design at great room windows and master bedroom windows, 2x12 Header corner to corner locations shown on plans, tension straps and nail exterior sheathing per design -12” oc nailing at abutting and intersecting corner - see master bedroom -Install TJC37 truss hanger at J2 hip Truss covered deck -top plate to top plate corner connection at front entry wall -rear south and north corners at daylight wall in basement, bottom plate and (3) studs at corner nailed 12” oc together -add bocca protection plate at bottom plate DWV basement bedroom closet -fireblock vertical every 10’ between studs and foundation/framing throughout finished basement -bocca protection plate at top plate DWV finished basement bath -seal top plate penetrations at basement bath -anchor SCH 40 steel columns to floor at basement -Gas line bond required
Gas Service Inspection - Residential Passed 3/29/2022 3/29/2022 03/29/2022
Misc
Resolved
03/29/2022
All Rough Inspection - Residential Failed 3/29/2022 3/29/2022 03/29/2022
Misc
Corrective Action Required
03/23/2022
-install all missing windows -CS-PF bracing design at master bedroom windows, nail exterior sheathing per design -Land wiring to boxes at covered deck -top plate to top plate corner connection at front entry wall -rear south and north corners at daylight wall in basement, bottom plate and (3) studs at corner nailed 12” oc together
Erosion Control Inspection Residential Partial 3/29/2022 3/29/2022 03/29/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
03/29/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Corrective Action Required
03/29/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
All Rough Inspection - Residential Passed 3/31/2022 3/31/2022 03/31/2022
Misc
Resolved
03/31/2022
Erosion Control Inspection Residential Passed 3/31/2022 3/31/2022 03/31/2022
Misc
Corrective Action Required
03/29/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Sidewalk Inspection Partial 4/26/2022 04/26/2022
Misc
Informational
04/26/2022
On 4.26.2022 Tuesday I performed a sidewalk inspection and pass the subgrade to pour concrete.
Driveway Inspection Partial 4/26/2022 04/26/2022
Misc
Informational
04/26/2022
On 4.26.2022 Tuesday I performed a driveway inspection and pass the subgrade to pour concrete after additional compaction.
Driveway Inspection Passed 5/3/2022 5/3/2022 05/02/2022
Misc
Informational
04/26/2022
On 4.26.2022 Tuesday I performed a driveway inspection and pass the subgrade to pour concrete after additional compaction.
Sidewalk Inspection Passed 5/3/2022 5/3/2022 05/02/2022
Misc
Informational
04/26/2022
On 4.26.2022 Tuesday I performed a sidewalk inspection and pass the subgrade to pour concrete.
Piers/Caissons Inspection - Residential Passed 6/6/2022 (10:45) 6/6/2022 06/06/2022
Occupancy Inspection - Codes Residential Failed 6/8/2022 6/8/2022 06/08/2022
Misc
Corrective Action Required
06/08/2022
-final grade and sod -splash blocks -deck under construction at inspection, complete deck -max 3/8” variance between stair rises at front entry stairs IRC R311.7.5.1 -install handrail/guardrail front entry stairs -hammer arrestor required at dishwasher -provide handrail at garage stairs -6’8” min headroom clearance required at basement stairs, IRC R311.7.2 -understair protection required at basement stairs IRC R302.7 -secure AC electrical whip, clamp within 12” of disconnect
Occupancy Inspection - Codes Residential Failed 6/9/2022 6/9/2022 06/09/2022
Misc
Corrective Action Required
06/08/2022
-final grade and sod -splash blocks -Repair damaged siding on south side of house
Occupancy Inspection - Codes Residential Temporary C of O 6/9/2022 6/9/2022 06/09/2022
Misc
Corrective Action Required
06/09/2022
-final grade and sod -splash blocks -Repair damaged siding on south side of house **OK FOR TCO - TCO EXPIRES 7/8/22**
Erosion Control Inspection Residential Partial 06/09/2022
Water Service Inspection - R Passed 7/6/2022 7/6/2022 07/06/2022
Occupancy Inspection - Codes Residential Full C of O 8/4/2022 8/4/2022 08/04/2022
Misc
Resolved
08/04/2022
-final grade and sod -splash blocks -Repair damaged siding on south side of house **OK FOR TCO - TCO EXPIRES 7/8/22**
Documents & Images
Date Uploaded File Type Document Name
07/22/2021 OS #30 - PERMIT APP2
07/27/2021 Approved Plans APPROVED DRAWINGS
07/27/2021 Plot Plan APPROVED PLOT PLAN
07/27/2021 Permit Codes Residential Plan Review
08/31/2021 Approved Plans APPROVED TRUSS LAYOUT
08/31/2021 Approved Plans APPROVED TRUSS PACKAGE
09/01/2021 Permit DS Building Permit
09/01/2021 Receipt Receipt for transaction:2021-007022
10/13/2021 M L Crose 3825 SW Maryville Pl LSMO Osage Lot 30 Clayton P 2021-3825 3rd Party Footing Inspection Report 10-6-21
10/14/2021 Letter INSPECTION SUMMARY
10/22/2021 Receipt Receipt for transaction: 2021-008192
11/03/2021 Letter INSPECTION SUMMARY
11/22/2021 OS #30 - Scope of Work Statement
11/22/2021 Approved Plans APPROVED DRAWINGS
11/23/2021 Receipt Receipt for transaction:2021-008899
12/06/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
03/23/2022 Letter INSPECTION SUMMARY
03/23/2022 Letter INSPECTION SUMMARY
03/23/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
03/31/2022 Letter INSPECTION SUMMARY
03/31/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter Codes Temporary Certificate of Occupancy
06/09/2022 Letter INSPECTION SUMMARY
07/06/2022 Letter INSPECTION SUMMARY
08/04/2022 Letter Codes Final Certificate of Occupancy
08/04/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home