Summary
PRRES20213585
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX - UNFINISHED BASEMENT ON UNIT B (3822 SW WALSH) - FINISHED BASEMENT ON UNIT A (3824 SW WALSH) UNCOVERED PATIO
07/12/2021
07/13/2021
01/09/2022
08/09/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Duplex $1,676.02 $1,676.02 Paid 07/13/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/13/2021
7232302-Residential Excise Tax Fee $2,154.24 $2,154.24 Paid 07/13/2021
8331507-Sewer Connection Fee $780.00 $780.00 Paid 07/13/2021
8331401-Water Tap Fee $7,310.00 $7,310.00 Paid 07/13/2021
8350015-Water Meter Fee $958.48 $958.48 Paid 07/13/2021
8331504-EFHB Middle Big Creek, Full $870.48 $870.48 Paid 10/22/2021
9110078-Valuation Fee New Single Family $46.40 $46.40 Paid 02/10/2022
$1,722.42
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/28/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $100.00 $100.00 Paid 06/28/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/28/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/28/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/8/2021 10/8/2021 10/08/2021
Underslab Plumbing Inspection - Residential Failed 10/11/2021 10/11/2021 10/11/2021
Misc
Corrective Action Required
10/11/2021
3822 OK 3824 INSTALL SPLICE AT INTERIOR DRAIN TILE
Underslab Plumbing Inspection - Residential Passed 10/15/2021 10/15/2021 10/15/2021
Misc
Informational
10/15/2021
3822 3824 OK
Sewer Service Inspection - R Partial 10/26/2021 10/26/2021
Misc
Informational
10/26/2021
3822 OK
Sewer Service Inspection - R Passed 11/1/2021 (2:15) 11/1/2021 11/01/2021
Misc
Informational
10/26/2021
3822 3824 OK
Water Service Inspection - R Passed 11/3/2021 11/03/2021
Misc
Informational
11/03/2021
3822,3824 OK
Gas Service Inspection - Residential Failed 03/29/2022
Misc
Corrective Action Required
03/29/2022
3822 - MIN 10 PSI REQUIRED FOR TEST 3824 - OK
Erosion Control Inspection Residential Partial 3/29/2022 3/29/2022 03/29/2022
Misc
Corrective Action Required
03/29/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
All Rough Inspection - Residential Not Ready 4/12/2022 4/12/2022 04/12/2022
Misc
Corrective Action Required
04/12/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
Rated Assembly Inspection Failed 4/12/2022 4/12/2022 04/12/2022
Misc
Corrective Action Required
04/12/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
Erosion Control Inspection Residential Failed 04/13/2022
Misc
Corrective Action Required
03/29/2022
-Provide gravel filter at drive to the house
Rated Assembly Inspection Failed 4/13/2022 4/13/2022 04/13/2022
Misc
Corrective Action Required
04/12/2022
-Address missing shaft liner above tub in 3824, shaft short of C track at roof several locations, rock not in H track near exterior walls, and damaged H track installed out of installation sequence
All Rough Inspection - Residential Failed 4/13/2022 4/13/2022 04/13/2022
Misc
Corrective Action Required
04/12/2022
4/13/22 NO INSPECTION PERFORMED -ADDRESS RATED ASSEMBLY AND COMPLETE GAS AND ELECTRICAL SERVICES FOR INSPECTION.
Electrical Service Inspection Failed 4/26/2022 4/26/2022 04/26/2022
Misc
Corrective Action Required
04/26/2022
Post address on meter can disconnect exterior
Gas Service Inspection - Residential Passed 4/26/2022 4/26/2022 04/26/2022
Misc
Resolved
04/26/2022
Rated Assembly Inspection Failed 4/26/2022 4/26/2022 04/26/2022
Misc
Corrective Action Required
04/13/2022
3824 - repair damaged sections of fire rock
All Rough Inspection - Residential Failed 4/26/2022 4/26/2022 04/26/2022
Misc
Corrective Action Required
04/13/2022
UNIT 3822: -min 2x6 required for HVAC furred down garage ceiling with R-19 insulation -(4) 2X stud packs all girder truss bearing ends per plans, stud packs should be same direction as stud nailed together under bearing load point -fur down for HVAC front entry closet -(3) 2x10 joist garage per plans -(3) stud pack dbl lvl garage wall per plans -replace stud pack at dbl 2x10 garage with graded lumber -dbl every other 2x10 joist at cantilever per plans garage -provide attic access garage per plans -(2) 2x4 trimmers garage entry per plans -provide access to UFER ground at garage wall at finish -12” oc nailing all intersecting corners -LIB bracing at master bed and 2nd floor per plans -CS-PF bracing design at great room windows, (2) 2x12 header per plans -(2) 2x4 trimmers at foyer and great room windows per plans -all truss lateral bracing per plans -attic access at 2nd floor must be accessible, half currently over staircase -address floor joist bored less than 2” from end of joist for gas line basement den -provide 3” SCH 40 steel column at W8x10 steel beam per plans, pier location “A” stair wall UNIT 3824: -min 2x6 required for HVAC furred down garage ceiling with R-19 insulation -fur down for HVAC front entry closet -provide access to UFER ground at garage wall at finish -fireblock HVAC chase pantry -Fireblock deadspace behind master shower -provide stud shoe DWV master vanity -provide 30” vertical clearance at attic access master closet -12” oc nailing all intersecting corners -(4) 2X stud packs all girder truss bearing ends per plans, stud packs should be same direction as stud nailed together under bearing load point -(3) 2x10 joist at garage per plans -dbl every other 2x10 joist at cantilever per plans garage -provide attic access garage per plans -(2) 2x4 trimmers garage entry per plans -LIB bracing all locations per plans -(2) 2x4 trimmers at foyer and great room windows per plans -repair bath vent fan duct at master bath -provide nail protection plates at stud penetrations behind shower 2nd floor -provide stud shoe 2nd floor bath vanity -connect vent line above tub 2nd floor -provide joist hangers at joist to dbl rim connection at basement egress window -provide 3” SCH 40 steel column at W8x10 steel beam per plans, pier location “A” stair wall -replace damaged sections of fire rock
Electrical Service Inspection Passed 5/3/2022 5/3/2022 05/03/2022
Misc
Resolved
05/03/2022
Rated Assembly Inspection Passed 5/3/2022 5/3/2022 05/03/2022
Misc
Resolved
05/03/2022
All Rough Inspection - Residential Failed 5/3/2022 5/3/2022 05/03/2022
Misc
Corrective Action Required
04/26/2022
UNIT 3822: -LIB bracing at 2nd floor per plans, (2) nails at each stud and plate, nail strap behind tub -2nd floor attic access, relocate electrical across opening, protect all NM within 6’ of attic entry -address floor joist bored less than 2” from end of joist for gas line basement den UNIT 3824: -provide 30” vertical clearance at attic access master closet -LIB bracing all locations per plans, see garage -nail LIB straps min (2) nails each stud and plate -provide stud shoe 2nd floor bath vanity -nail LIB strap at 2nd floor tub
All Rough Inspection - Residential Failed 5/5/2022 5/5/2022 05/05/2022
Misc
Corrective Action Required
05/03/2022
-ADDRESS EROSION CONTROL FRONT OF LOT UNIT 3822: -LIB bracing at 2nd floor per plans, (2) nails at each stud and plate, nail strap behind tub -address floor joist bored less than 2” from end of joist for gas line basement den, (provide engineer letter on approved field fix) UNIT 3824: -nail LIB strap at 2nd floor tub
Erosion Control Inspection Residential Failed 5/5/2022 5/5/2022 05/05/2022
Misc
Corrective Action Required
04/13/2022
-MAINTAIN EROSION CONTROL ON LOT
All Rough Inspection - Residential Not Ready 5/9/2022 5/9/2022 05/09/2022
Misc
Corrective Action Required
05/05/2022
-ADDRESS EROSION CONTROL FRONT OF LOT UNIT 3822: -LIB bracing at 2nd floor per plans, (2) nails at each stud and plate, LOOK BEHIND THE TUB, STRAP NOT NAILED OFF -address floor joist bored less than 2” from end of joist for gas line basement den, (provide engineer letter on approved field fix) UNIT 3824: -nail LIB strap at 2nd floor tub, LOOK BEHIND THE TUB, STRAP NOT NAILED OFF
All Rough Inspection - Residential Not Ready 5/11/2022 5/11/2022 05/11/2022
Misc
Corrective Action Required
05/09/2022
**UNITS INSULATED WITHOUT APPROVAL, REMOVE INSULATION AT INSPECTION ITEMS TO ALLOW FOR INSULATION** UNIT 3822: -LIB bracing at 2nd floor per plans, (2) nails at each stud and plate, LOOK BEHIND THE TUB, STRAP NOT NAILED OFF UNIT 3824: -nail LIB strap at 2nd floor tub, LOOK BEHIND THE TUB, STRAP NOT NAILED OFF
All Rough Inspection - Residential Passed 5/11/2022 5/11/2022 05/11/2022
Misc
Resolved
05/11/2022
Driveway Inspection Partial 5/17/2022 5/17/2022 05/17/2022
Misc
Informational
05/17/2022
On 5.17.2022 I performed a driveway inspection and pass the inspection to pour concrete.
Sidewalk Inspection Partial 6/14/2022 6/14/2022 06/14/2022
Misc
Informational
06/14/2022
On 6.14.2022 I performed a sidewalk inspection and pass the sub-grade to pour concrete.
Sidewalk Inspection Passed 6/23/2022 6/23/2022 06/23/2022
Misc
Informational
06/14/2022
On 6.14.2022 I performed a sidewalk inspection and pass the sub-grade to pour concrete. On 6.23.2022 the sidewalk appears to be compliant.
Occupancy Inspection - Codes Residential Failed 6/23/2022 6/23/2022 06/23/2022
Misc
Corrective Action Required
06/23/2022
-Final driveway and sidewalk inspections required -resolve all outstanding inspection fees -final grade and sod' -submit as graded plot plan for review and approval -splash blocks 3824 -open ground laundry GFCI outlet -breaker lockout at hot water heater -blank off unused breaker location -mark all breaker locations -AFCI protection at all required circuits per code -hot water heater discharge pipe max 6" AFF -install light fixture at sliding glass door -tempered glass required at great room windows per R308.4.3 3822 -Label circuit breaker locations -AFCI protection at all required circuits per code -tempered glass required at great room windows per R308.4.3 -install GFCI outlet at back patio
Occupancy Inspection - Codes Residential Failed 6/24/2022 6/24/2022 06/24/2022
Misc
Corrective Action Required
06/23/2022
Sheetrock Ufer ground location and install sheetrock mud ring and an approved electrical cover plate. Stairs on both units need to be removed and sheetrock installed for garage separation. -Final driveway and sidewalk inspections required , still pending from 6/23 Please contact Diana Johnson 969-1219 -resolve all outstanding inspection fees -final grade and sod' -submit as graded plot plan for review and approval -splash blocks 3824 -AFCI protection at all required circuits per code -install light fixture at sliding glass door -tempered glass required at great room windows per R308.4.3 3822 -AFCI protection at all required circuits per code -tempered glass required at great room windows per R308.4.3
Driveway Inspection Passed 6/23/2022 6/23/2022 06/27/2022
Misc
Informational
05/17/2022
On 5.17.2022 I performed a driveway inspection and pass the inspection to pour concrete. 6.23.2022 Driveway appears to be in compliant.
Occupancy Inspection - Codes Residential Failed 6/27/2022 6/27/2022 06/27/2022
Misc
Corrective Action Required
06/24/2022
-Sheetrock Ufer ground location and install sheetrock mud ring and an approved electrical cover plate.-PROVIDE APPROVED ELECTRICAL COVER PLATE -resolve all outstanding fees -final grade and sod' -submit as graded plot plan for review and approval -splash blocks
Occupancy Inspection - Codes Residential Temporary C of O 6/28/2022 6/28/2022 06/28/2022
Misc
Corrective Action Required
06/27/2022
-final grade and sod' -submit as graded plot plan for review and approval -splash blocks **OK FOR TCO 3824 AND 3822, TCO EXPIRES 7/28/22
Water Service Inspection - R Passed 7/1/2022 07/01/2022
Water Service Inspection - R Passed 7/7/2022 07/07/2022
Occupancy Inspection - Codes Residential Failed 7/21/2022 7/21/2022 07/21/2022
Misc
Corrective Action Required
06/28/2022
-permanent addresses meter can and disconnects -submit as graded plot plan for review and approval -splash blocks **OK FOR TCO 3824 AND 3822, TCO EXPIRES 7/28/22
Erosion Control Inspection Residential Passed 8/2/2022 08/02/2022
Misc
Resolved
08/02/2022
-MAINTAIN EROSION CONTROL ON LOT
Plot Plan Inspection Passed 8/2/2022 08/02/2022
Occupancy Inspection - Codes Residential Failed 8/2/2022 8/2/2022 08/02/2022
Misc
Corrective Action Required
07/21/2022
-permanent addresses meter can and DISCONNECTS(missing in disconnects) **OK FOR TCO 3824 AND 3822, TCO EXPIRES 7/28/22
Occupancy Inspection - Codes Residential Full C of O 8/9/2022 8/9/2022 08/09/2022
Misc
Resolved
08/09/2022
Documents & Images
Date Uploaded File Type Document Name
07/12/2021 Application Form OS #21 - PERMIT APP
07/13/2021 Permit Codes Residential Plan Review
07/13/2021 Permit Codes Residential Plan Review
07/13/2021 Permit DS Building Permit
07/13/2021 Receipt Receipt for transaction:2021-005595
08/31/2021 Approved Plans APPROVED TRUSS PACKAGE
08/31/2021 Approved Plans APPROVED TRUSS LAYOUT
10/06/2021 3822 & 3824 SW Walsh Dr LSMO Osage Lot 21 Clayton Properties 3rd Party Footing Inspection Report 9-10-21
10/07/2021 3822 & 3824 SW Walsh Dr LSMO Osage Lot 21 Clayton Properties 3rd Party Footing Inspection Report 9-10-21 Revised 10-7-21.pdf
10/07/2021 RE_ Third party footing Osage 3822 & 3824 SW Walsh Dr PRRES20213585.msg
10/08/2021 Letter INSPECTION SUMMARY
10/11/2021 Letter INSPECTION SUMMARY
10/15/2021 Letter INSPECTION SUMMARY
10/22/2021 Receipt Receipt for transaction: 2021-008192
10/26/2021 Letter INSPECTION SUMMARY
11/01/2021 Letter INSPECTION SUMMARY
11/11/2021 Letter INSPECTION SUMMARY
01/27/2022 Approved Plans Approved Drawings
02/10/2022 Approved Plans Approved Basement Plan
02/10/2022 Receipt Receipt for transaction:2022-000756
03/29/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter INSPECTION SUMMARY
05/03/2022 Letter INSPECTION SUMMARY
05/03/2022 Letter INSPECTION SUMMARY
05/03/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter INSPECTION SUMMARY
05/10/2022 21 osage letter
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
06/01/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
06/24/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/28/2022 Receipt Receipt for transaction:2022-005209
06/28/2022 Letter Codes Temporary Certificate of Occupancy
06/29/2022 LOT 21 MINOR PLAT SEAL
06/30/2022 Plot Plan Approved Plot Plan
07/01/2022 Letter INSPECTION SUMMARY
07/07/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/28/2022 Plot Plan Approved As Graded Plot Plan
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/09/2022 Letter Field Certificate of Occupancy
08/09/2022 Letter Codes Final Certificate of Occupancy
01/29/2024 LOT 21 ASBUILT
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home