Permit Application Status

PRRES20213404


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213404
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW RESIDENTIAL CONSTRUCTION. UNFINISHED BASEMENT - UNCOVERED PATIO
07/01/2021
07/08/2021
01/03/2022
07/25/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JOE@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/08/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/08/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 07/08/2021
9110078-Valuation Fee New Single Family $1,178.49 $1,178.49 Paid 07/08/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 07/08/2021
8331507-Sewer Connection Fee $450.00 $450.00 Paid 07/08/2021
8331504-EFHB Middle Big Creek, Full $502.20 $502.20 Paid 10/22/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/30/2021 9/30/2021 09/30/2021
Misc
Informational
09/30/2021
APPROVED PER DAVID P AINSWORTH 9/17/21
Underslab Plumbing Inspection - Residential Passed 10/19/2021 10/19/2021 10/19/2021
Sewer Service Inspection - R Passed 12/14/2021 (1:00) 12/14/2021 12/14/2021
Water Service Inspection - R Passed 12/17/2021 (11:15) 12/17/2021 12/17/2021
Erosion Control Inspection Residential Failed 12/17/2021 12/17/2021 12/17/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/17/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Gas Service Inspection - Residential Failed 2/3/2022 2/3/2022 02/03/2022
Misc
Corrective Action Required
02/03/2022
GAS LINE BOND REQUIRED PRESSURE OK
Electrical Service Inspection Failed 2/3/2022 2/3/2022 02/03/2022
Misc
Corrective Action Required
02/03/2022
-REPLACE ACORN STYLE CLAMP FOR GEC TO UFER TO ONE THAT IS RATED FOR REBAR CONNECTION SEPARATION
All Rough Inspection - Residential Failed 2/3/2022 2/3/2022 02/03/2022
Misc
Corrective Action Required
02/03/2022
-Address over notched studs at garage portal wall for NM -tension straps required at garage PFH -fireblock vertical to horizontal at furred down soffit ends -fur down at HVAC at garage ceiling to allow for insulation -NM bundled at home run above service panel, remove zip ties -address top plate cut for HVAC at garage wall, dbl 2x10 joist not supported by load bearing wall -fireblock HVAC chase at great room -Install back door -address 2X4 to 2x6 top plate connection at stair wall as required per code -secure attic light box -protect NM within 6’ of attic access 2nd floor -smoke/co required outside of bedroom at learning lounge -2x6 full height stud wall at basement stair wall grade beam per plans -nail off joist hangers above furnace at Basement -replace acorn style clamp for GEC to UFER to one that is rated for rebar connection, separation of dissimilar metals -gas line bond required
All Rough Inspection - Residential Passed 2/9/2022 2/9/2022 02/09/2022
Misc
Resolved
02/09/2022
Gas Service Inspection - Residential Passed 2/9/2022 2/9/2022 02/09/2022
Misc
Resolved
02/09/2022
Electrical Service Inspection Passed 2/9/2022 2/9/2022 02/09/2022
Misc
Resolved
02/09/2022
Driveway Inspection Passed 3/1/2022 04/07/2022
Misc
Informational
03/01/2022
On Tuesday 3.1.2022 I performed a driveway inspection and pass the subgrade to pour concrete at the time of this inspection
Sidewalk Inspection Partial 4/7/2022 4/7/2022 04/07/2022
Misc
Informational
04/07/2022
On 4.7.2022 Thursday I performed a sidewalk inspection and pass the subgrade to pour concrete
Occupancy Inspection - Codes Residential Failed 4/20/2022 4/20/2022 04/20/2022
Misc
Corrective Action Required
04/20/2022
-maintain erosion control on lot until sod is placed -move portable John toilet off street -post address -final sidewalk inspection required, contact development services to schedule -submit as graded plot plan for review and approval -final grade and sod -gutters and downspouts required -splash blocks all downspouts and sump pump locations, min 36” discharge from foundation -guardrail required at front porch, more than 30” from grade -handrail required at front stairs, 4 rises -seal all penetrations in siding, seal along top of AC disconnect and meter can -install hardware sliding glass door -secondary toe lock required at sliding glass door -label all breaker locations service panel -provide breaker lockout for hot water heater circuit -tempered glass required at lowest window 1st floor/2nd floor stair landing -smoke/co detector required in hall outside of the triple bedrooms 2nd floor rear, one installed is smoke only -hot water heater discharge pipe maximum 6” AFF -provide tamper resistant caps at AC valves
Driveway Inspection Passed 04/22/2022
Misc
Informational
03/01/2022
On Tuesday 3.1.2022 I performed a driveway inspection and pass the subgrade to pour concrete at the time of this inspection
Sidewalk Inspection Passed 4/22/2022 4/22/2022 04/22/2022
Misc
Informational
04/07/2022
On 4.7.2022 Thursday I performed a sidewalk inspection and pass the subgrade to pour concrete
Occupancy Inspection - Codes Residential Temporary C of O 4/26/2022 4/26/2022 04/26/2022
Misc
Corrective Action Required
04/20/2022
-submit as graded plot plan for review and approval -final grade and sod -gutters and downspouts required -splash blocks all downspouts and sump pump locations, min 36” discharge from foundation **OK FOR TCO - TCO EXPIRES 5/26/22**
Occupancy Inspection - Codes Residential Temporary C of O 5/26/2022 05/26/2022
Misc
Corrective Action Required
04/26/2022
-submit as graded plot plan for review and approval -final grade and sod -gutters and downspouts required -splash blocks all downspouts and sump pump locations, min 36” discharge from foundation -correct water meter height
Erosion Control Inspection Residential Passed 06/13/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/13/2022
Occupancy Inspection - Codes Residential Failed 6/13/2022 6/13/2022 06/13/2022
Misc
Corrective Action Required
05/26/2022
-submit as graded plot plan for review and approval
Plot Plan Inspection Passed 7/18/2022 07/18/2022
Occupancy Inspection - Codes Residential Failed 7/18/2022 7/18/2022 07/18/2022
Misc
Corrective Action Required
06/13/2022
-replace sod removed at rear of lot
Occupancy Inspection - Codes Residential Full C of O 7/25/2022 7/25/2022 07/25/2022
Misc
Resolved
07/25/2022
Documents & Images
Date Uploaded File Type Document Name
07/01/2021 OS #37 - PERMIT APP
07/07/2021 Approved Plans Approved Drawings
07/07/2021 Permit Codes Residential Plan Review
07/08/2021 Plot Plan Approved Plot Plan
07/08/2021 Permit Codes Residential Plan Review
07/08/2021 Permit DS Building Permit
07/08/2021 Receipt Receipt for transaction:2021-005476
08/30/2021 Approved Plans APPROVED TRUSS LAYOUT
08/31/2021 Approved Plans APPROVED TRUSS PACKAGE
09/30/2021 M L Crose 2118 SW Rutherford Dr LSMO Clayton Permit 2021-3404 3rd Party Footing Inspection Report 9-17-21
09/30/2021 Letter INSPECTION SUMMARY
10/19/2021 Letter INSPECTION SUMMARY
10/22/2021 Receipt Receipt for transaction: 2021-008192
12/14/2021 Letter INSPECTION SUMMARY
12/17/2021 Letter INSPECTION SUMMARY
12/17/2021 Letter INSPECTION SUMMARY
02/03/2022 Letter INSPECTION SUMMARY
02/03/2022 Letter INSPECTION SUMMARY
02/03/2022 Letter INSPECTION SUMMARY
02/03/2022 Letter INSPECTION SUMMARY
02/08/2022 37 Osage over notched studs letter
02/09/2022 Letter INSPECTION SUMMARY
02/09/2022 Letter INSPECTION SUMMARY
02/09/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter Codes Temporary Certificate of Occupancy
05/26/2022 Letter Codes Temporary Certificate of Occupancy
05/26/2022 Email Osage Single Family Water Meters and TCO's
06/13/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter INSPECTION SUMMARY
07/13/2022 Plot Plan Approved As Graded Plot Plan
07/18/2022 Letter INSPECTION SUMMARY
07/18/2022 Letter INSPECTION SUMMARY
07/25/2022 Letter Field Certificate of Occupancy
07/25/2022 Letter Codes Final Certificate of Occupancy
01/29/2024 LOT 37 ASBUILT
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home