Summary
PRRES20213319
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED PATIO STOP WORK ORDER generated on 09/01/2021 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 09/02/2021 12:00 AM by username 'Patrick Schonfeldt'.
06/28/2021
07/01/2021
12/25/2021
08/18/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
AJ@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/01/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/01/2021
9110078-Valuation Fee New Single Family $1,497.93 $1,497.93 Paid 07/01/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 07/01/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 07/01/2021
8331504-EFHB Middle Big Creek, Full $703.08 $703.08 Paid 07/01/2021
8331507-Sewer Connection Fee $630.00 $630.00 Paid 07/01/2021
9110078-Valuation Fee New Single Family $67.02 $67.02 Paid 10/28/2021
$1,564.95
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/04/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/04/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 07/04/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 9/1/2021 9/1/2021 09/01/2021
Misc
Corrective Action Required
09/01/2021
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION, ENGINEER REPORT REQUIRED TO BE SUBMITTED TO PERMIT WITHIN 48 HOURS OF INSPECTION
Footing Inspection - Residential Failed - Stop Work 9/1/2021 9/1/2021 09/01/2021
Misc
Corrective Action Required
09/01/2021
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION, ENGINEER REPORT REQUIRED TO BE SUBMITTED TO PERMIT WITHIN 48 HOURS OF INSPECTION
Footing Inspection - Residential Passed 9/2/2021 9/2/2021 09/02/2021
Misc
Informational
09/02/2021
APPROVED PER BRADLEY HUXOL 7/30/21
Underslab Plumbing Inspection - Residential Failed 9/3/2021 9/3/2021 09/03/2021
Misc
Corrective Action Required
09/01/2021
UNABLE TO PERFORM INSPECTION WITH MUD WATER COVERING DWV FROM RAIN, RESCHEDULE WHEN CONDITIONS ALLOW FOR INSPECTION
Underslab Plumbing Inspection - Residential Passed 9/14/2021 9/14/2021 09/14/2021
Misc
Resolved
09/14/2021
All Rough Inspection - Residential Partial 10/18/2021 10/18/2021 10/18/2021
Misc
Informational
10/18/2021
-GARAGE PORTAL EXTERIOR OK TO COVER
Sewer Service Inspection - R Passed 11/9/2021 11/9/2021 11/09/2021
Water Service Inspection - R Partial 11/10/2021 11/10/2021 11/10/2021
Water Service Inspection - R Passed 11/10/2021 (11:30) 11/10/2021 11/10/2021
Erosion Control Inspection Residential Failed 11/10/2021 11/10/2021 11/10/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/10/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Not Ready 2/14/2022 2/14/2022 02/14/2022
Misc
Informational
10/18/2021
-GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Corrective Action Required
02/14/2022
INSPECTION DENIED -Maintain erosion control on lot, maintain silt fence at front of lot, erosion control required at rear of lot to protect creek, remove construction trash and debris from creek/tree line rear of lot -Maintain the gravel filter on drive, min 6” lift with gravel -Have complete city stamped set of plans on site, plans on site have torn pages and missing pages Correct all issues above before rescheduling inspection
Erosion Control Inspection Residential Failed 2/14/2022 2/14/2022 02/14/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/10/2021
Inspection Denied -Maintain erosion control on lot, maintain silt fence at front of lot, erosion control required at rear of lot to protect creek, remove construction trash and debris from creek/tree line rear of lot -Maintain the gravel filter on drive, min 6” lift with gravel -Have complete city stamped set of plans on site, plans on site have torn pages and missing pages Correct all issues above before rescheduling an inspection
Electrical Service Inspection Passed 2/16/2022 2/16/2022 02/16/2022
Gas Service Inspection - Residential Failed 2/16/2022 2/16/2022 02/16/2022
Misc
Corrective Action Required
02/16/2022
GAS PRESSURE 7 PSI, MUST MAINTAIN 10 PSI FOR TEST
All Rough Inspection - Residential Failed 2/16/2022 2/16/2022 02/16/2022
Misc
Informational
02/14/2022
-GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Corrective Action Required
02/14/2022
-EROSION CONTROL REQUIRED AT REAR OF LOT AND SIDE OF LOT, PROTECT CREEK, CLEAN TRASH FROM CREEK, DO NOT RESCHEDULE INSPECTION UNTIL ADDRESSED -anchor bolts within 12” of plate break garage -full support corner stud at sgl garage door corner east -H2.5 or equivalent all trusses garage -solid block between joists lateral restraint above beam garage -fireblock at furred down soffit ends garage -address overnotched studs for anchor bolts at garage wall -solid block sheathing breaks -fur out at garage wall HVAC to allow for insulation -structural straps at top plates bored 50% or more all exterior walls and interior load bearing walls, strap min 1 1/2” wide, 16 gauge and must extend 6” passed each side of opening with (4) 10D nails each side of strap -Fireblock HVAC chase at garage entry -header cut floor joists for HVAC at chase garage entry -secure all vertical DWV 2” or less at mid point -strap top plate garage wall HVAC -seal all top and bottom plate penetrations -solid block between joists at cantilevers -provide stud shoes at kitchen exterior wall for DWV -solid block at all step flashing -Install back door -top plate to top plate connection per code at dining room exterior wall -provide full bearing for front covered porch ridge -fireblock vertical to horizontal at great room window chases -secure CSST gas line at fireplace -connect and screw HVAV duct above 1st floor bath -provide stud shoes at studs bored for data tube at fireplace -CS-PF bracing at dining room exterior wall per plans -provide additional studs for full bearing of 2nd floor stud pack at dining room exterior wall per plans -vent all bath exhaust fans to exterior -follow manufacture installation instructions concerning vertical run in stud wall and protection of CSST gas line at 1st floor bedroom -(4) 2x4 stud pack all girder trusses bearing ends per plans -Anchor steel column at first floor stair -Repair damaged sub floor by stairs -Seal bottom plate penetration at stairs -Protect nm at stairwell less than 1.25” to face of stud -Address dwv bored less than 2” to top of joist at great room -Nail corner all corner studs and intersecting wall studs per code -Address exterior walls not tied together at top plate at entry wall/bedroom -Address plates not overlapped 24” at entry wall -Solid block and nail horizontal seams at horizontal breaks in sheathing at front bed -(4) 2x4 stud pack at all GT locations -Seal top and bottom plate penetrations at front upstairs bath -Provide missing truss hangers at hips -Support vtr at elbow in back bedroom -Seal bottom plate penetration at master bed -Fireblock radon chase with approved means -Fireblock triangle dead spaces by master with approved means -Bocca plate at master -Complete electrical at master bath -Solid shim all trimmer studs cut short of header -fireblock vertical every 10” between studs and foundation wall at basement, this includes stair wall as well -provide (2) 2x10 header at basement egress window per plans -fur out finished basement wall for sump pump discharge line -nail all exterior sheathing per plans LIST INCOMPLETE, UNACCEPTABLE AMOUNT OF CORRECTIONS
All Rough Inspection - Residential Failed 3/1/2022 3/1/2022 03/01/2022
Misc
Resolved
03/01/2022
-GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Corrective Action Required
02/16/2022
-secure all vertical DWV 2” or less at mid point -provide stud shoes at kitchen exterior wall for DWV -Install back door -connect and screw HVAV duct above 1st floor bath -provide stud shoes at studs bored for data tube at fireplace -vent all bath exhaust fans to exterior ,1st floor bath -Anchor steel column at first floor stair -Repair damaged sub floor by stairs -Seal bottom plate penetration at stairs -Protect nm at stairwell less than 1.25” to face of stud -Address dwv bored less than 2” to top of joist at great room -Address exterior walls not tied together at top plate at entry wall/bedroom east side .,., -Provide missing truss hangers at hips -Support vtr at elbow in back bedroom -Fireblock radon chase with approved means,2nd floor to attic. -Fireblock triangle dead spaces by master with approved means 2nd floor. -Bocca plate at master -fireblock vertical every 10” between studs and foundation wall at basement, this includes stair wall as well, provide foam at studs -fur out finished basement wall for sump pump discharge line -nail all exterior sheathing per plans
Gas Service Inspection - Residential Failed 3/1/2022 3/1/2022 03/01/2022
Misc
Corrective Action Required
02/16/2022
GAS PRESSURE 7 PSI, MUST MAINTAIN 10 PSI FOR TEST
All Rough Inspection - Residential Failed 3/3/2022 3/3/2022 03/03/2022
Misc
Corrective Action Required
03/01/2022
-connect and screw HVAV duct above 1st floor bath -vent all bath exhaust fans to exterior ,1st floor bath -Provide missing truss hangers at hips OK to insulate
Gas Service Inspection - Residential Passed 3/9/2022 3/9/2022 03/09/2022
Misc
Resolved
03/09/2022
GAS PRESSURE 7 PSI, MUST MAINTAIN 10 PSI FOR TEST
All Rough Inspection - Residential Not Ready 3/9/2022 3/9/2022 03/09/2022
Misc
Corrective Action Required
03/03/2022
-connect and screw HVAV duct above 1st floor bath -vent all bath exhaust fans to exterior ,1st floor bath,basement OK to insulate
All Rough Inspection - Residential Passed 3/15/2022 3/15/2022 03/15/2022
Misc
Resolved
03/15/2022
Erosion Control Inspection Residential Partial 3/15/2022 3/15/2022 03/15/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
03/15/2022
Inspection Denied -Maintain erosion control on lot, maintain silt fence at front of lot, erosion control required at rear of lot to protect creek, remove construction trash and debris from creek/tree line rear of lot -Maintain the gravel filter on drive, min 6” lift with gravel -Have complete city stamped set of plans on site, plans on site have torn pages and missing pages Correct all issues above before rescheduling an inspection
Misc
Corrective Action Required
03/15/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Sidewalk Inspection Partial 4/5/2022 4/5/2022 04/05/2022
Misc
Informational
04/05/2022
Sidewalk was framed up with aggregate in and compacted. 4/5/22 ES
Driveway Inspection Partial 4/5/2022 4/5/2022 04/05/2022
Misc
Informational
04/05/2022
Driveway was framed up with aggregate in and compacted. 4/5/22 ES
Driveway Inspection Passed 4/15/2022 4/15/2022 04/15/2022
Misc
Informational
04/05/2022
Driveway was framed up with aggregate in and compacted. 4/5/22 ES
Misc
Informational
04/15/2022
Driveway meets LS and Ada specs. 4/15/22 ES
Sidewalk Inspection Passed 4/15/2022 4/15/2022 04/15/2022
Misc
Informational
04/05/2022
Sidewalk was framed up with aggregate in and compacted. 4/5/22 ES
Misc
Informational
04/15/2022
Sidewalk meets LS and Ada specs. 4/15/22 ES
Occupancy Inspection - Codes Residential Failed 6/27/2022 6/27/2022 06/27/2022
Misc
Corrective Action Required
06/27/2022
-RESOLVE OUTSTANDING INSPECTION FEES -LABEL ALL BREAKER LOCATIONS AT SUB PANEL -SHEAR OFF SET SCREW ANTI SIPHON DEVICE ON SPIGOT MAIN WATER LINE BASEMENT -REMOVE DUST COVERS FROM SMOKES -UNCOVER MANHOLE AT FRONT OF LOT AS SHOWN ON PLOT PLANS
Plot Plan Inspection Failed 06/27/2022
Misc
Corrective Action Required
06/27/2022
UNCOVER MANHOLE AT FRONT OF LOT AS SHOWN ON PLOT PLAN
Erosion Control Inspection Residential Passed 06/27/2022
Misc
Resolved
06/27/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Occupancy Inspection - Codes Residential Temporary C of O 6/27/2022 6/27/2022 06/27/2022
Misc
Corrective Action Required
06/27/2022
-RESOLVE OUTSTANDING INSPECTION FEES -UNCOVER MANHOLE AT FRONT OF LOT AS SHOWN ON PLOT PLANS **OK FOR TCO, TCO EXPIRES 7/27/22
Occupancy Inspection - Codes Residential Failed 7/7/2022 7/7/2022 07/07/2022
Misc
Corrective Action Required
06/27/2022
-UNCOVER MANHOLE AT FRONT OF LOT AS SHOWN ON PLOT PLANS ***7-7-22 THIS HAS NOT BEEN CORRECTED **OK FOR TCO, TCO EXPIRES 7/27/22
Plot Plan Inspection Passed 8/18/2022 8/18/2022 08/18/2022
Misc
Resolved
08/18/2022
Occupancy Inspection - Codes Residential Full C of O 8/18/2022 8/18/2022 08/18/2022
Misc
Resolved
08/18/2022
Documents & Images
Date Uploaded File Type Document Name
06/28/2021 RR #78 - PERMIT APP
06/28/2021 RR #78 - Winchester - Modern Farmhouse - Sheets- signed
06/28/2021 Approved Plans Approved Truss Layout
06/28/2021 Approved Plans Approved Truss Package
06/28/2021 Permit Codes Residential Plan Review
06/29/2021 Approved Plans Approved Drawings
06/30/2021 Plot Plan Approved Plot Plan
06/30/2021 Permit Codes Residential Plan Review
07/01/2021 Permit DS Building Permit
07/01/2021 Receipt Receipt for transaction:2021-005267
09/01/2021 Letter INSPECTION SUMMARY
09/01/2021 Letter Stop Work Order
09/01/2021 Lot 78 Reserve at Stoney Creek Footing Inspection
09/01/2021 Lot 78 Reserve at Stoney Creek Foundation Inspection
09/02/2021 Letter INSPECTION SUMMARY
09/03/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter INSPECTION SUMMARY
10/18/2021 Letter INSPECTION SUMMARY
10/25/2021 RR #78 - Scope of Work Statement
10/25/2021 Approved Plans Basement Finish Plan
10/25/2021 Approved Plans Approved Revised Truss Layout
10/28/2021 Receipt Receipt for transaction:2021-008328
11/09/2021 Letter INSPECTION SUMMARY
11/10/2021 Letter INSPECTION SUMMARY
11/10/2021 Letter INSPECTION SUMMARY
11/10/2021 Letter INSPECTION SUMMARY
02/14/2022 Letter INSPECTION SUMMARY
02/14/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/03/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter Codes Temporary Certificate of Occupancy
07/04/2022 Receipt Receipt for transaction:2022-005476
07/07/2022 Letter INSPECTION SUMMARY
08/18/2022 Letter INSPECTION SUMMARY
08/18/2022 Letter Field Certificate of Occupancy
08/18/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home