Permit Application Status

PRRES20213190


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213190
Building Permit - Residential
Certificate of Occupancy
NEW MARK HOMES-KC LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK LOT USED TO BE IN A FLOOD PLAIN BUT THAT NO LONGER EXISTS DUE TO FILL FEMA LETTER OF MAP REVISION BASED ON FILL FOR LOT 2 IS ATTACHED IN DOCUMENTS AND IMAGES
06/22/2021
06/30/2021
12/20/2021
09/15/2023
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
NEW MARK HOMES-KC LLC, Address:5207 NW CROOKED RD  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
CLASS ONE ELECTRIC INC, Address:PO BOX 24343, Phone:(913) 915-1767  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
SCOTT@NEWMARKHONESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,031.04 $1,031.04 Paid 06/30/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/30/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/30/2021
8331507-Sewer Connection Fee $420.00 $420.00 Paid 06/30/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 06/30/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 06/30/2021
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 05/11/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/11/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/01/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/01/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/21/2021 (11:30) 7/21/2021 07/21/2021
Underslab Plumbing Inspection - Residential Passed 9/8/2021 9/8/2021 09/08/2021
Erosion Control Inspection Residential Failed 9/8/2021 9/8/2021 09/08/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/08/2021
9-8-21 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Restore silt fence at perimeter of lot
Sewer Service Inspection - R Passed 1/27/2022 (10:30) 1/27/2022 01/27/2022
Water Service Inspection - R Passed 1/28/2022 01/28/2022
Electrical Service Inspection Failed 5/5/2022 5/5/2022 05/05/2022
Misc
Corrective Action Required
05/05/2022
-Ground service to copper water line per code
Gas Service Inspection - Residential Failed 5/5/2022 5/5/2022 05/05/2022
Misc
Corrective Action Required
05/05/2022
-No pressure
All Rough Inspection - Residential Failed 5/5/2022 5/5/2022 05/05/2022
Misc
Corrective Action Required
05/05/2022
**REPAIR EROSION CONTROL AT REAR OF LOT -Provide a smoke/CO alarm immediately outside front bedroom -Protect water lines at master toilet wall -Bolt rafter connections per 2/S3.2 above master closet -Fb back wall of fireplace space -Brace ends of lvl roof beams against rotation -Install ceiling joist hangers above stair -Protect csst gas line per manufacturer at fireplace -Nail all required round holes at lvl-lvl connections above kitchen -Nail rear dining CSPF wall siding per 1/S4.1. Header min (2)2x12 -Support 2x12 valley rafter above garage/stoop wall -Brace interior walls per plan -Make the bottom stair winder treads consistent in depth with max difference of no more than 3/8” at walkline. Min 6” depth at narrow end -Anchor steel columns to floor -Secure SE cable within 12” of meter enclosure -Nail hangers above bedroom 5 closet and adjacent bathroom -Seal gaps at vertical fire blockings -Fb bedroom 4 wall from soffit -Toe nail joists to basement foundation wall sill plates per code -Provide combustion air openings per code **DO NOT INSULATE
Electrical Service Inspection Failed 7/14/2022 7/14/2022 07/14/2022
Misc
Corrective Action Required
05/05/2022
-Ground service to copper water line per code
Misc
Corrective Action Required
07/14/2022
inspection denied due to erosion control still not in compliance.
Gas Service Inspection - Residential Failed 7/14/2022 7/14/2022 07/14/2022
Misc
Corrective Action Required
05/05/2022
-No pressure
Misc
Corrective Action Required
07/14/2022
inspection denied erosion control still not in compliance.
Erosion Control Inspection Residential Failed 7/14/2022 07/14/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/08/2021
9-8-21 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Restore silt fence at perimeter of lot
Misc
Corrective Action Required
07/14/2022
erosion control still not in compliance silt fence maintain vegetation
All Rough Inspection - Residential Not Ready 7/14/2022 7/14/2022 07/14/2022
Misc
Corrective Action Required
05/05/2022
INSPECTION DENIED EROSION CONTROL NOT REPAIRED **REPAIR EROSION CONTROL AT REAR OF LOT -Provide a smoke/CO alarm immediately outside front bedroom -Protect water lines at master toilet wall -Bolt rafter connections per 2/S3.2 above master closet -Fb back wall of fireplace space -Brace ends of lvl roof beams against rotation -Install ceiling joist hangers above stair -Protect csst gas line per manufacturer at fireplace -Nail all required round holes at lvl-lvl connections above kitchen -Nail rear dining CSPF wall siding per 1/S4.1. Header min (2)2x12 -Support 2x12 valley rafter above garage/stoop wall -Brace interior walls per plan -Make the bottom stair winder treads consistent in depth with max difference of no more than 3/8” at walkline. Min 6” depth at narrow end -Anchor steel columns to floor -Secure SE cable within 12” of meter enclosure -Nail hangers above bedroom 5 closet and adjacent bathroom -Seal gaps at vertical fire blockings -Fb bedroom 4 wall from soffit -Toe nail joists to basement foundation wall sill plates per code -Provide combustion air openings per code **DO NOT INSULATE
All Rough Inspection - Residential Failed 7/22/2022 7/22/2022 07/22/2022
Misc
Corrective Action Required
07/14/2022
-Fb back wall of fireplace space complete and used approved methods -Nail rear dining CSPF wall siding per 1/S4.1. Header min (2)2x12(address engineer letter referring to different area than detail) -Fb bedroom 4 wall from soffit
Electrical Service Inspection Passed 7/22/2022 7/22/2022 07/22/2022
Misc
Resolved
07/22/2022
-Ground service to copper water line per code
Misc
Resolved
07/22/2022
inspection denied due to erosion control still not in compliance.
Gas Service Inspection - Residential Passed 7/22/2022 7/22/2022 07/22/2022
Misc
Resolved
07/22/2022
-No pressure
Misc
Resolved
07/22/2022
inspection denied erosion control still not in compliance.
All Rough Inspection - Residential Passed 7/25/2022 7/25/2022 07/25/2022
Misc
Resolved
07/25/2022
-Fb back wall of fireplace space complete and used approved methods -Nail rear dining CSPF wall siding per 1/S4.1. Header min (2)2x12(address engineer letter referring to different area than detail) -Fb bedroom 4 wall from soffit
Driveway Inspection Passed 8/29/2022 8/29/2022 08/29/2022
Misc
Informational
08/29/2022
On Monday, 8-29-2022. I performed and passed the driveway for concrete placement.
Sidewalk Inspection Passed 8/29/2022 8/29/2022 08/29/2022
Misc
Informational
08/29/2022
On Monday, 8-29-2022. I performed and passed a sidewalk inspection for placement of concrete.
Miscellaneous Inspection Passed 4/26/2023 04/26/2023
Misc
Informational
04/26/2023
permit extended for another 180 days spoke with craig with New Mark
Occupancy Inspection - Codes Residential Failed 5/8/2023 5/8/2023 05/08/2023
Misc
Corrective Action Required
05/08/2023
-address pending pier inspection -splash block and sump pump discharge to extend 36” from foundation -provide as graded plot plan -label all non GFCI outlets in unfinished spaces -security screws at rear patio door -identify sewer tracer wire -water meter well to grade. Ensure 14”-18” from meter top to lid ring -obtain lawn irrigation permit
Piers/Caissons Inspection - Residential Passed 5/9/2023 05/09/2023
Informational
05/09/2023
poured with the footing
Occupancy Inspection - Codes Residential Ready for Temp CO 5/10/2023 5/10/2023 05/10/2023
Misc
Corrective Action Required
05/08/2023
-provide as graded plot plan -security screws at rear patio door 2 per hinge and strike plate -water meter well to grade. Ensure 14”-18” from meter top to lid ring
Occupancy Inspection - Codes Residential Failed 5/11/2023 5/11/2023 05/11/2023
Misc
Corrective Action Required
05/10/2023
PAY FEE -provide as graded plot plan -water meter well to grade. Ensure 14”-18” from meter top to lid ring
Plot Plan Inspection Passed 6/5/2023 06/05/2023
Occupancy Inspection - Codes Residential Failed 8/10/2023 8/10/2023 08/10/2023
Misc
Corrective Action Required
05/11/2023
-water meter well lid to grade. Ensure 14”-18” from meter top to lid ring
Occupancy Inspection - Codes Residential Failed 8/31/2023 08/31/2023
Misc
Corrective Action Required
08/10/2023
-water meter well lid to grade. Ensure 14”-18” from meter top to lid ring -TCO expiring please submit TCO extension or complaint listed item
Occupancy Inspection - Codes Residential Full C of O 9/15/2023 9/15/2023 09/15/2023
Misc
Resolved
09/15/2023
-water meter well lid to grade. Ensure 14”-18” from meter top to lid ring
Documents & Images
Date Uploaded File Type Document Name
06/23/2021 WW02 APPLICATION AND TAX_001
06/23/2021 Letter FEMA LOMR-F Whispering Woods 1st Plat
06/23/2021 Permit Codes Residential Plan Review
06/29/2021 Plot Plan Approved Plot Plan
06/29/2021 Permit Codes Residential Plan Review
06/30/2021 Permit DS Building Permit
06/30/2021 Receipt Receipt for transaction:2021-005174
06/30/2021 2021_06_30_New Mark Homes_21-003 Whispering Woods Lot 2_Sealed
06/30/2021 Approved Plans Approved Drawings
07/21/2021 Letter INSPECTION SUMMARY
09/08/2021 Letter INSPECTION SUMMARY
09/08/2021 Letter INSPECTION SUMMARY
01/27/2022 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
07/13/2022 2022_06_24_21-003 Whispering Woods Lot 2_Interior CS-PF Letter(1)
07/14/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
07/25/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
04/07/2023 Letter Codes 180 Day Letter
05/08/2023 Letter INSPECTION SUMMARY
05/08/2023 Letter INSPECTION SUMMARY
05/09/2023 Letter INSPECTION SUMMARY
05/11/2023 Letter INSPECTION SUMMARY
05/11/2023 Certificate/License Codes Temporary Certificate of Occupancy
05/11/2023 Receipt Receipt for transaction:2023-003109
06/02/2023 Plot Plan APPROVED AS BUILT PLOT PLAN
06/05/2023 Letter INSPECTION SUMMARY
08/01/2023 Certificate/License Codes Temporary Certificate of Occupancy
08/01/2023 Certificate/License Codes Temporary Certificate of Occupancy
08/01/2023 Receipt Receipt for transaction:2023-005939
08/10/2023 Letter INSPECTION SUMMARY
08/31/2023 Letter INSPECTION SUMMARY
08/31/2023 Letter INSPECTION SUMMARY
09/15/2023 Letter Field Certificate of Occupancy
09/15/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: