Summary
PRRES20213188
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - UNCOVERED DECK
06/22/2021
06/24/2021
12/19/2021
05/10/2023
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
SUPERIORREALESTATESERVICES@GMAIL.COM  
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,106.02 $1,106.02 Paid 06/24/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/24/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/24/2021
8331507-Sewer Connection Fee $480.00 $480.00 Paid 06/24/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 06/24/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 06/24/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/15/2021 (2:30) 9/15/2021 09/15/2021
Underslab Plumbing Inspection - Residential Passed 10/5/2021 10/5/2021 10/05/2021
Sewer Service Inspection - R Passed 10/18/2021 (1:00) 10/18/2021 10/18/2021
Water Service Inspection - R Passed 10/20/2021 10/20/2021
Electrical Service Inspection Passed 3/8/2022 03/08/2022
Erosion Control Inspection Residential Failed 3/8/2022 03/08/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/08/2022
DEFICIENT EROSION CONTROL INSTALLATION. RESTORE EROSION CONTROL ALONG THE STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
All Rough Inspection - Residential Failed 3/8/2022 3/8/2022 03/08/2022
Misc
Corrective Action Required
03/08/2022
-Nail siding to sill plates per code -Brace bedroom 3 lvl ridge support stud above stair from rotation -Vent master bath fan to outdoor -Install 2x12 purlin above great room per plan. Support purlin to bearing wall&beam -Install hangers at ceiling joist connections to ceiling beam above half bathroom -Extend return air to ceiling level above wet bar area -Dryer duct length exceeds limits with 4 equivalent 90-deg elbows. Duct with this many elbows can only go 15 ft max -Anchor basement column **OK TO INSULATE
Gas Service Inspection - Residential Passed 3/8/2022 03/08/2022
All Rough Inspection - Residential Passed 4/1/2022 4/1/2022 04/01/2022
Misc
Resolved
04/01/2022
-Nail siding to sill plates per code **OK TO INSULATE
Driveway Inspection Partial 6/8/2022 6/8/2022 06/08/2022
Misc
Informational
06/08/2022
6-8-22 AN forms are in place and aggregate is present and compacted
Sidewalk Inspection Partial 6/8/2022 6/8/2022 06/08/2022
Misc
Informational
06/08/2022
6-8-22 AN forms are in place and aggregate is present and compacted
Driveway Inspection Passed 6/13/2022 6/13/2022 06/14/2022
Misc
Informational
06/08/2022
6-8-22 AN forms are in place and aggregate is present and compacted 6-14-22 AN driveway looks good and has expansion joints at curb and right of way
Sidewalk Inspection Partial 6/13/2022 6/13/2022 06/14/2022
Misc
Informational
06/08/2022
6-8-22 AN forms are in place and aggregate is present and compacted 6-14-22 AN sidewalk looks good and meets Ada spec
Sidewalk Inspection Passed 06/14/2022
Misc
Informational
06/14/2022
6-8-22 AN forms are in place and aggregate is present and compacted 6-14-22 AN sidewalk looks good and meets Ada spec
Erosion Control Inspection Residential Passed 10/28/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
10/28/2022
DEFICIENT EROSION CONTROL INSTALLATION. RESTORE EROSION CONTROL ALONG THE STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 10/28/2022 10/28/2022 10/28/2022
Misc
Corrective Action Required
10/28/2022
-Obtain lawn irrigation permit and submit backflow valve test report to city. Permit application is incomplete -Provide splash blocks and sump pump extension -Install tamper-proof caps at AC valves -Provide sewer tracer wire port at grade -Garage door not self-closing -Provide gfci protection for dishwasher outlet (not tripping) -Screw the exterior door embedded jamb brace into studs through the 4 pre-drilled holes with min 3” screws -Install cranks for bedroom windows -Provide min 1.5” clearance around stair handrail -Complete furnace exhaust and intake piping connection; support piping every 5 ft or less -Protect wiring running across bottom of joists per code -Provide breaker lock for oven -Label or identify all dedicated non-gfci receptacles in basement
Occupancy Inspection - Codes Residential Failed 5/5/2023 5/5/2023 05/05/2023
Misc
Corrective Action Required
10/28/2022
-Obtain lawn irrigation permit and submit backflow valve test report to city. Permit application is incomplete **Irrigation permit is still in "incomplete" status -Provide sewer tracer wire port at grade **not done -Screw the exterior door embedded jamb brace into studs through the 4 pre-drilled holes with min 3” screws
Occupancy Inspection - Codes Residential Full C of O 5/10/2023 5/10/2023 05/10/2023
Misc
Resolved
05/10/2023
-Provide sewer tracer wire port at grade **not done -Screw the exterior door embedded jamb brace into studs through the 4 pre-drilled holes with min 3” screws
Documents & Images
Date Uploaded File Type Document Name
06/22/2021 Application Form Permit Application and License Tax Form
06/22/2021 Approved Plans Approved Drawings
06/22/2021 Permit Codes Residential Plan Review
06/23/2021 Plot Plan Approved Plot Plan
06/23/2021 Permit Codes Residential Plan Review
06/24/2021 Permit DS Building Permit
06/24/2021 Receipt Receipt for transaction:2021-004913
09/15/2021 Letter INSPECTION SUMMARY
10/05/2021 Letter INSPECTION SUMMARY
10/18/2021 Letter INSPECTION SUMMARY
10/20/2021 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
10/28/2022 Letter INSPECTION SUMMARY
10/28/2022 Letter INSPECTION SUMMARY
05/05/2023 Letter INSPECTION SUMMARY
05/08/2023 20230505_152535
05/10/2023 20230509_153537
05/10/2023 Letter Codes Final Certificate of Occupancy
05/10/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home