NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED PATIO STOP WORK ORDER generated on 05/16/2022 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 06/15/2022 12:00 AM by username 'Mitchell Schwarz'.
06/17/2021
06/23/2021
12/14/2021
07/26/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
LOREN@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $360.00 $360.00 Paid 06/23/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 06/23/2021
Water Meter Fee $455.54 $455.54 Paid 06/23/2021
Right of Way Permit Fee $80.00 $80.00 Paid 06/23/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/23/2021
Valuation Fee New Single Family $972.98 $972.98 Paid 06/23/2021
Valuation Fee New Single Family $45.94 $45.94 Paid 02/28/2022
$1,018.92
Not Ready Inspection Fee $50.00 $50.00 Paid 07/11/2022
Not Ready Inspection Fee $50.00 $50.00 Paid 07/11/2022
Not Ready Inspection Fee $50.00 $50.00 Paid 07/11/2022
Temporary Occupancy Fee $50.00 $50.00 Paid 07/14/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/13/2021 (11:30) 7/13/2021 07/13/2021
Underslab Plumbing Inspection - Residential Passed 8/18/2021 8/18/2021 08/18/2021
Sewer Service Inspection - R Passed 10/19/2021 10/19/2021
Water Service Inspection - R Passed 10/21/2021 (11:30) 10/21/2021 10/21/2021
Erosion Control Inspection Residential Failed 10/21/2021 10/21/2021 10/21/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/21/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Not Ready 3/9/2022 3/9/2022 03/09/2022
Misc
Corrective Action Required
03/09/2022
inspection denied no city stamped plans on site erosion control not in compliance
Erosion Control Inspection Residential Failed 3/9/2022 03/09/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/21/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Mitchell Schwarz 03/09/2022 10:16 AM
Misc
Corrective Action Required
03/09/2022
EROSION CONTROL NOT IN COMPLIANCE MAINTAIN EROSION CONTROL -GRAVEL FILTER NEEDS MAINTAINED -CLEAN UP STREET -CLEAN AND MAINTAIN STORM INLET
DCM5 ESC INSP DENIED
Corrective Action Required
03/16/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. Mitchell Schwarz 03/16/2022 1:45 PM
Erosion Control Inspection Residential Failed 3/16/2022 03/16/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/09/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Mitchell Schwarz 03/09/2022 10:16 AM
Misc
Corrective Action Required
03/09/2022
EROSION CONTROL NOT IN COMPLIANCE MAINTAIN EROSION CONTROL -GRAVEL FILTER NEEDS MAINTAINED -CLEAN UP STREET -CLEAN AND MAINTAIN STORM INLET
DCM5 ESC INSP DENIED
Corrective Action Required
03/16/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. Mitchell Schwarz 03/16/2022 1:46 PM
All Rough Inspection - Residential Failed 3/16/2022 3/16/2022 03/16/2022
Misc
Corrective Action Required
03/09/2022
inspection denied erosion control not in compliance (see previous failed erosion control for details)
Electrical Service Inspection Passed 3/30/2022 3/30/2022 03/30/2022
Gas Service Inspection - Residential Failed 3/30/2022 3/30/2022 03/30/2022
Misc
Corrective Action Required
03/30/2022
provide 10psi and gauge for gas inspection
Erosion Control Inspection Residential Failed 3/30/2022 03/30/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
03/30/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Mitchell Schwarz 03/09/2022 10:16 AM
Misc
Resolved
03/30/2022
EROSION CONTROL NOT IN COMPLIANCE MAINTAIN EROSION CONTROL -GRAVEL FILTER NEEDS MAINTAINED -CLEAN UP STREET -CLEAN AND MAINTAIN STORM INLET
DCM5 ESC INSP DENIED
Resolved
03/30/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. Mitchell Schwarz 03/16/2022 1:46 PM
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/30/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. street clean up erosion control at back of lot
All Rough Inspection - Residential Failed 3/30/2022 3/30/2022 03/30/2022
Misc
Resolved
03/30/2022
inspection denied erosion control not in compliance (see previous failed erosion control for details)
Misc
Corrective Action Required
03/30/2022
-Anchor bolt to be within 6” of sill plate break -all anchor bolts to be in the middle 1/3 of sill plate -fire block for radon at rear garage wall to attic space -protect NM with in 6’ of attic access -add h2.5 at Gt. bearing locations -snow block -secure gas line at fireplace -strap top plate right of rear sliding door -add studs per plans at rear sliding door -all hanger and lateral bracing for truss per plans -support ridge beam at front stoop -anchor All steel columns in basement -sold block under kitchen island per plans -sold block above beam in basement -address cut joist above steel beam in bed 4 -nail all double joist in basement together to code -address supply above basement bath in furr down
Gas Service Inspection - Residential Failed 4/6/2022 4/6/2022 04/06/2022
Misc
Corrective Action Required
03/30/2022
provide 10psi and gauge for gas inspection
All Rough Inspection - Residential Failed 4/6/2022 04/06/2022
Misc
Corrective Action Required
03/30/2022
-fire block for radon at rear garage wall to attic space -protect NM with in 6’ of attic access -add studs per plans at rear sliding door - lateral bracing for truss per plans -support ridge beam at front stoop -sold block under kitchen island per plans -install all garage doors and doors
All Rough Inspection - Residential Failed 4/11/2022 4/11/2022 04/11/2022
Misc
Corrective Action Required
04/06/2022
-install all garage doors and doors **OK to insulate
Gas Service Inspection - Residential Not Ready 4/11/2022 4/11/2022 04/11/2022
Misc
Corrective Action Required
04/06/2022
provide 10psi and gauge for gas inspection *4-11-22 Still no pressure at gauge-not ready
Erosion Control Inspection Residential Failed 4/11/2022 4/11/2022 04/11/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/11/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. street clean up erosion control
Miscellaneous Correction
Corrective Action Required
04/11/2022
**4-11-22 Clean streets, correct tipped over port-a-john immediately, clean trash from storm inlet
Gas Service Inspection - Residential Passed 4/13/2022 4/13/2022 04/13/2022
Misc
Resolved
04/13/2022
provide 10psi and gauge for gas inspection *4-11-22 Still no pressure at gauge-not ready
All Rough Inspection - Residential Passed 4/19/2022 4/19/2022 04/19/2022
Misc
Corrective Action Required
04/11/2022
-install all garage doors **OK to insulate and drywall will check garage doors at final
Erosion Control Inspection Residential Failed 5/9/2022 05/09/2022
Miscellaneous Correction
Corrective Action Required
04/11/2022
**4-11-22 Clean streets, correct tipped over port-a-john immediately, clean trash from storm inlet
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/09/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -clean steet -maintain gravel filter
Driveway Inspection Passed 5/12/2022 5/12/2022 05/12/2022
Misc
Informational
05/12/2022
On Thursday 5-12-2022. I performed and passed driveway inspection for the above location.
Erosion Control Inspection Residential Failed - Stop Work 5/16/2022 05/16/2022
Miscellaneous Correction
Corrective Action Required
05/09/2022
**4-11-22 Clean streets, correct tipped over port-a-john immediately, clean trash from storm inlet
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/09/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -clean steet -maintain gravel filter
Misc
Corrective Action Required
05/16/2022
Erosion control still Not in compliance 5/16/22
Erosion Control Inspection Residential Failed 5/20/2022 5/20/2022 05/20/2022
Miscellaneous Correction
Corrective Action Required
05/16/2022
**4-11-22 Clean streets, correct tipped over port-a-john immediately, clean trash from storm inlet
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/16/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -clean steet -maintain gravel filter
Misc
Corrective Action Required
05/16/2022
Erosion control still Not in compliance 5/16/22
Misc
Corrective Action Required
05/20/2022
inspection denied no address posted Mitchell Schwarz 05/20/2022 11:19 AM
Erosion Control Inspection Residential Partial 6/15/2022 6/15/2022 06/15/2022
Miscellaneous Correction
Resolved
06/15/2022
**4-11-22 Clean streets, correct tipped over port-a-john immediately, clean trash from storm inlet
DCM3 ESC REQUIRED 2 DAY
Resolved
06/15/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -clean steet -maintain gravel filter
Misc
Resolved
06/15/2022
Erosion control still Not in compliance 5/16/22
Misc
Resolved
06/15/2022
inspection denied no address posted Mitchell Schwarz 05/20/2022 11:19 AM
Misc
Informational
06/15/2022
Erosion control in compliance at time of inspection. Mitchell Schwarz 06/15/2022 1:49 PM
Occupancy Inspection - Codes Residential Failed 6/21/2022 6/21/2022 06/21/2022
Misc
Resolved
06/21/2022
check garage doors
Misc
Corrective Action Required
06/21/2022
-pay all fees -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at final grade and sod -guard rail at front stoop as required by code -obtain lawn irrigation permit -outlet right of sink countertop in kitchen GFCI protection required -set screw sheared off at water anti syphon device
Occupancy Inspection - Codes Residential Not Ready 6/24/2022 6/24/2022 06/24/2022
Misc
Corrective Action Required
06/21/2022
-pay all fees -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at final grade and sod -guard rail at front stoop as required by code -obtain lawn irrigation permit -outlet right of sink countertop in kitchen GFCI protection required -set screw sheared off at water anti syphon device
Erosion Control Inspection Residential Passed 7/7/2022 07/07/2022
Misc
Informational
06/15/2022
Erosion control in compliance at time of inspection. Mitchell Schwarz 06/15/2022 1:49 PM Shawn Hoffman 07/07/2022 11:31 AM
Occupancy Inspection - Codes Residential Failed 7/7/2022 7/7/2022 07/07/2022
Misc
Corrective Action Required
06/24/2022
-pay all fees -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at final grade and sod -guard rail at front stoop as required by code -obtain lawn irrigation permit
Plot Plan Inspection Passed 7/11/2022 07/11/2022
Occupancy Inspection - Codes Residential Ready for Temp CO 7/11/2022 7/11/2022 07/11/2022
Misc
Corrective Action Required
07/07/2022
TCO UNTIL 8/10/22 -pay all fees -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at final grade and sod -obtain lawn irrigation permit
Occupancy Inspection - Codes Residential Temporary C of O 7/14/2022 7/14/2022 07/14/2022
Misc
Corrective Action Required
07/11/2022
TCO UNTIL 8/10/22 -pay all fees -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at final grade and sod -obtain lawn irrigation permit
Occupancy Inspection - Codes Residential Full C of O 7/26/2022 7/26/2022 07/26/2022
Misc
Resolved
07/26/2022
TCO UNTIL 8/10/22 -pay all fees -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at final grade and sod -obtain lawn irrigation permit
Documents & Images
Date Uploaded File Type Document Name
06/17/2021 H4 #102 - PERMIT APP
06/17/2021 Plot Plan Approved Plot Plan
06/17/2021 Permit Codes Residential Plan Review
06/23/2021 Approved Plans Approved Drawings
06/23/2021 Approved Plans Approved Truss Layout
06/23/2021 Approved Plans Approved Truss Package
06/23/2021 Permit Codes Residential Plan Review
06/23/2021 Permit DS Building Permit
06/23/2021 Receipt Receipt for transaction:2021-004885
07/13/2021 Letter INSPECTION SUMMARY
08/18/2021 Letter INSPECTION SUMMARY
10/19/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
02/28/2022 H4 #102 - Scope of Work Statement Application
02/28/2022 Approved Plans Approved Basement Plan
02/28/2022 Receipt Receipt for transaction:2022-001049
03/09/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/11/2022 Letter INSPECTION SUMMARY
04/11/2022 Letter INSPECTION SUMMARY
04/11/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/19/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter INSPECTION SUMMARY
05/12/2022 Letter INSPECTION SUMMARY
05/16/2022 Letter Stop Work Order
05/20/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/24/2022 Letter INSPECTION SUMMARY
07/07/2022 Letter INSPECTION SUMMARY
07/07/2022 Letter INSPECTION SUMMARY
07/11/2022 Receipt Receipt for transaction:2022-005643
07/11/2022 Letter INSPECTION SUMMARY
07/14/2022 Receipt Receipt for transaction:2022-005751
07/14/2022 Letter Codes Temporary Certificate of Occupancy
07/26/2022 Letter Codes Final Certificate of Occupancy
07/26/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home