Permit Application Status

PRRES20213077


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213077
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - ROOF TRUSSES - COVERED DECK
06/15/2021
06/21/2021
12/12/2021
07/21/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid 06/21/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 06/21/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/21/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/21/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 06/21/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 06/21/2021
9110078-Valuation Fee New Single Family $874.52 $874.52 Paid 06/21/2021
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/20/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/3/2021 8/3/2021 08/03/2021
Misc
Informational
08/03/2021
APPROVED PER BRADLEY HUXOL 7/27/21
Underslab Plumbing Inspection - Residential Passed 8/19/2021 8/19/2021 08/19/2021
Miscellaneous Correction
Corrective Action Required
08/19/2021
Post address
Sewer Service Inspection - R Passed 8/25/2021 (10:00) 8/25/2021 08/25/2021
Water Service Inspection - R Partial 8/25/2021 8/25/2021 08/25/2021
Misc
Informational
08/25/2021
PARTIAL INSPECTION ON PEX TO HOUSE ENTRY
Water Service Inspection - R Passed 8/26/2021 (1:30) 8/26/2021 08/26/2021
Misc
Resolved
08/26/2021
Erosion Control Inspection Residential Failed 8/26/2021 8/26/2021 08/26/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/26/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Passed 3/24/2022 3/24/2022 03/24/2022
Gas Service Inspection - Residential Passed 3/24/2022 3/24/2022 03/24/2022
All Rough Inspection - Residential Failed 3/24/2022 3/24/2022 03/24/2022
Misc
Corrective Action Required
03/24/2022
-anchor bolts required within 12” of plate breaks at garage, install nuts and washers all anchor bolts -seal all top plate penetrations - see garage, kitchen -fireblock garage wall/foundation at beam -min 24” offset between top plate breaks - see garage -provide bocca protection plate DWV top and bottom plate laundry -set electrical boxes to stud face at dbl wall laundry -address top plate to top plate connection as required by code at front entry wall -provide floor outlet at stair wall great room -seal gas line floor penetration at fireplace -solid shim all trimmer studs short of header throughout -fireblock between plates dbl wall at fridge kitchen -provide bocca protection plate at bottom plate pex fridge kitchen -Fireblock deadspace between top plate at master bed hall and master water closet -(4) 2X stud pack at all girder truss bearing ends per plans -all truss lateral bracing per the plans -bath exhaust fan required at basement bath -(5)2x6 stud pack at W8x24 steel beam basement rec room per plans -nail all exterior sheathing per plans
All Rough Inspection - Residential Passed 3/30/2022 3/30/2022 03/30/2022
Misc
Resolved
03/30/2022
Driveway Inspection Partial 4/18/2022 04/18/2022
Misc
Informational
04/18/2022
On 4.18.2022 I performed a driveway inspection and pass the subgrade to pour concrete.
Occupancy Inspection - Codes Residential Failed 7/19/2022 7/19/2022 07/19/2022
Misc
Corrective Action Required
07/19/2022
-final driveway inspection required contact development services to schedule -submit as graded plot plan for review and approval -final grade and sod -water meter to grade, maintain 14”-18” from meter to lid -gravel base at water meter pit -provide approved ledger lags at deck, truss structural screws not allowed -label all dedicated receptacles at garage and unfinished basement not GFCI protected -cover plates all outlets
Driveway Inspection Passed 7/19/2022 7/19/2022 07/19/2022
Misc
Informational
04/18/2022
On 4.18.2022 I performed a driveway inspection and pass the subgrade to pour concrete. On 7.19.2022 Driveway appears to be compliance
Occupancy Inspection - Codes Residential Ready for Temp CO 7/20/2022 7/20/2022 07/20/2022
Misc
Corrective Action Required
07/19/2022
TCO UNTIL 8/20/22 -final grade and sod -water meter to grade, maintain 14”-18” from meter to lid -gravel base at water meter pit
Plot Plan Inspection Passed 7/20/2022 07/20/2022
Occupancy Inspection - Codes Residential Temporary C of O 07/20/2022
Misc
Corrective Action Required
07/20/2022
TCO UNTIL 8/20/22 -final grade and sod -water meter to grade, maintain 14”-18” from meter to lid -gravel base at water meter pit
Erosion Control Inspection Residential Passed 07/21/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
07/21/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Full C of O 7/21/2022 7/21/2022 07/21/2022
Misc
Resolved
07/21/2022
Documents & Images
Date Uploaded File Type Document Name
06/15/2021 MN #91 - PERMIT APP
06/15/2021 Approved Plans APPROVED PLANS
06/15/2021 Approved Plans APPROVED TRUSS DRAWINGS
06/15/2021 Approved Plans APPROVED TRUSS LAYOUT
06/15/2021 Permit Codes Residential Plan Review
06/21/2021 Permit Codes Residential Plan Review
06/21/2021 Plot Plan APPROVED PLOT PLAN
06/21/2021 Permit DS Building Permit
06/21/2021 Receipt Receipt for transaction:2021-004691
08/02/2021 Lot 91 Manor at Stoney Creek Footing Inspection
08/03/2021 Letter INSPECTION SUMMARY
08/19/2021 Letter INSPECTION SUMMARY
08/25/2021 Letter INSPECTION SUMMARY
08/25/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
03/28/2022 91 manor at stoney creek letter
03/30/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
07/19/2022 LOT 91 ASBUILT
07/19/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
07/20/2022 Letter INSPECTION SUMMARY
07/20/2022 Letter INSPECTION SUMMARY
07/20/2022 Receipt Receipt for transaction:2022-005920
07/20/2022 Letter Codes Temporary Certificate of Occupancy
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter Field Certificate of Occupancy
07/21/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home