PRRES20212842
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
06/03/2021
06/04/2021
11/30/2021
12/12/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $420.00 $420.00 Paid 06/04/2021
8331504-EFHB Middle Big Creek, Full $468.72 $468.72 Paid 06/04/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/04/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/04/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 06/04/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 06/04/2021
9110078-Valuation Fee New Single Family $1,061.72 $1,061.72 Paid 06/04/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $100.00 $100.00 Paid 11/11/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 09/23/2021
Misc
Informational
09/23/2021
APPROVED PER BRADLEY HUXOL 7/21/21
Underslab Plumbing Inspection - Residential Passed 9/23/2021 9/23/2021 09/23/2021
Water Service Inspection - R Passed 10/12/2021 10/12/2021
Sewer Service Inspection - R Passed 10/12/2021 10/12/2021
Electrical Service Inspection Passed 5/24/2022 5/24/2022 05/24/2022
Gas Service Inspection - Residential Passed 5/24/2022 5/24/2022 05/24/2022
All Rough Inspection - Residential Failed 5/24/2022 5/24/2022 05/24/2022
Misc
Corrective Action Required
05/24/2022
-min 24” lap between dbl top plate breaks - see garage, laundry -(3) studs required at exterior corner connection, see laundry non continuous 2x4 used at 2x6 exterior wall corner -support all vertical DWV 2” or less at mid point -provide code compliant header for stud removed for kitchen hood exhaust -support ridge ends at covered front porch -address rafters at front covered porch landing on blocks -land NM to box at master bed wall -provide H2.5 clips at dbl girder truss master bedroom -unable to inspect trusses at covered deck with lid installed -provide all truss hangers per pans -provide all truss lateral bracing per plans -complete plumbing west basement den for master bed -fireblock between top plates at basement den windows -install basement egress window -tighten all anchor bolts basement -fireblock between top plate and foundation wall basement bedroom and bathroom -provide joist hangers at joist to dbl rim connection basement den -address triple floor joist bored less than 2” from end of joist for electrical, basement mech right of stair stringer **Due to conditions at time of inspection exterior not inspected, will inspect at reinspect, corrections list subject to change**
Erosion Control Inspection Residential Partial 05/24/2022
All Rough Inspection - Residential Failed 6/6/2022 6/6/2022 06/06/2022
Misc
Corrective Action Required
05/24/2022
-nail straps embedded in concrete at garage portal -provide deck ledger attachment to house per plans/code -provide (2) 1/2” through bolts at each post/beam connection per code -support all vertical DWV 2” or less at mid point -address rafters at front covered porch landing on blocks -land NM to box at master bed wall -complete plumbing west basement den for master bed -install basement egress window -tighten all anchor bolts basement -fireblock between top plate and foundation wall basement bedroom and bathroom -address triple floor joist bored less than 2” from end of joist for electrical, basement mech right of stair stringer
Erosion Control Inspection Residential Failed 6/6/2022 6/6/2022 06/06/2022
Misc
Corrective Action Required
06/06/2022
maintain gravel filter on drive
All Rough Inspection - Residential Failed 6/17/2022 6/17/2022 06/17/2022
Misc
Corrective Action Required
06/06/2022
-Upload engineer report to permit -install basement egress window **OK TO INSULATE**
Erosion Control Inspection Residential Failed 6/17/2022 6/17/2022 06/17/2022
Misc
Corrective Action Required
06/06/2022
maintain gravel filter on drive
All Rough Inspection - Residential Passed 6/21/2022 6/21/2022 06/21/2022
Misc
Resolved
06/21/2022
Driveway Inspection Partial 8/1/2022 8/1/2022 08/01/2022
Misc
Informational
08/01/2022
8.1.2022 I conducted a driveway inspection and pass the subgrade to pour concrete.
Sidewalk Inspection Partial 8/1/2022 8/1/2022 08/01/2022
Misc
Informational
08/01/2022
8.1.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete.
Driveway Inspection Passed 8/10/2022 (1:00) 8/10/2022 08/10/2022
Misc
Informational
08/01/2022
8.1.2022 I conducted a driveway inspection and pass the subgrade to pour concrete. 8.10.2022 Driveway appears to be compliant
Sidewalk Inspection Passed 8/10/2022 (1:00) 8/10/2022 08/10/2022
Misc
Informational
08/01/2022
8.1.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete. 8.10.2022 Sidewalk appears to be compliant
Piers/Caissons Inspection - Residential Passed 11/10/2022 11/10/2022 11/10/2022
Erosion Control Inspection Residential Passed 11/10/2022 11/10/2022 11/10/2022
Misc
Resolved
11/10/2022
maintain gravel filter on drive
Plot Plan Inspection Passed 11/10/2022 11/10/2022 11/10/2022
Occupancy Inspection - Codes Residential Failed 11/10/2022 11/10/2022 11/10/2022
Misc
Corrective Action Required
11/10/2022
-resolve outstanding inspection fees -splash blocks -provide gravel base at water meter -cover plates at laundry outlets, master bath -no access to jacuzzi tub motor master bedroom with current configuration, motor on opposite end of tub IRC P2720.1 -mark dedicated outlets at unfinished spaces as not GFCI protected -provide water pressure regulator at main water line
Occupancy Inspection - Codes Residential Failed 11/23/2022 11/23/2022 11/23/2022
Misc
Corrective Action Required
11/10/2022
-no access to jacuzzi tub motor master bedroom with current configuration, motor on opposite end of tub IRC P2720.1 (CURRENT CONFIGURATION OF ACCESS PANEL AT REC ROOM THROUGH FURRED DOWN AND SUB FLOOR DOESN'T RESULT IN SPACE REQUIRED TO MEET THE INTENT OF THE CODE WHICH IS TO PROVIDE UNOBSTRUCTED SPACE IN ORDER TO PERMIT REMOVAL AND REPLACEMENT OF THE CIRCULATION PUMP)
Occupancy Inspection - Codes Residential Full C of O 12/12/2022 12/12/2022 12/12/2022
Misc
Resolved
12/12/2022
Documents & Images
Date Uploaded File Type Document Name
06/03/2021 101 RESERVE AT STONEY CREEK ROOF LAYOUT
06/03/2021 RR #101 - PERMIT APP
06/03/2021 LOT 101 FINAL
06/03/2021 RR #101 - Somerview - Craftsman - Sheets- signed
06/03/2021 210431
06/03/2021 Permit Codes Residential Plan Review
06/03/2021 Approved Plans APPROVED PLANS
06/03/2021 Approved Plans APPROVED TRUSS DRAWINGS
06/03/2021 Approved Plans APPROVED TRUSS LAYOUT
06/04/2021 LOT 101 CITY
06/04/2021 Plot Plan APPROVED PLOT PLAN
06/04/2021 Permit Codes Residential Plan Review
06/04/2021 Permit DS Building Permit
06/04/2021 Receipt Receipt for transaction:2021-003909
09/23/2021 Lot 101 Reserve at Stoney Creek Footing Inspection
09/23/2021 Lot 101 Reserve at Stoney Creek Foundation Inspection
09/23/2021 Lot 101 Reserve at Stoney Creek Pier Inspection
09/23/2021 Letter INSPECTION SUMMARY
09/23/2021 Letter INSPECTION SUMMARY
10/12/2021 Letter INSPECTION SUMMARY
10/12/2021 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/17/2022 Letter INSPECTION SUMMARY
06/17/2022 Letter INSPECTION SUMMARY
06/21/2022 101 Reserve at Stoney Creek Letter
06/21/2022 Letter INSPECTION SUMMARY
08/01/2022 Letter INSPECTION SUMMARY
08/01/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter INSPECTION SUMMARY
11/10/2022 Letter INSPECTION SUMMARY
11/10/2022 Letter INSPECTION SUMMARY
11/10/2022 Letter INSPECTION SUMMARY
11/10/2022 Letter INSPECTION SUMMARY
11/11/2022 Receipt Receipt for transaction:2022-008871
11/23/2022 Letter INSPECTION SUMMARY
12/12/2022 Letter Field Certificate of Occupancy
12/12/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home