Permit Application Status

PRRES20212305


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212305
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSSES
05/06/2021
05/19/2021
11/03/2021
03/18/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Not shown for privacy reasons.
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/19/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 05/19/2021
8331507-Sewer Connection Fee $570.00 $570.00 Paid 05/19/2021
9110078-Valuation Fee New Single Family $1,270.61 $1,270.61 Paid 05/19/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 05/19/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 05/19/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 03/09/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 03/09/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/14/2021 (11:00) 6/14/2021 06/14/2021
Misc
Informational
06/14/2021
UFER LOCATED FOUNDATION WALL BEHIND FRONT STOOP
Sewer Service Inspection - R Passed 7/28/2021 07/28/2021
Water Service Inspection - R Passed 8/2/2021 (10:30) 8/2/2021 08/02/2021
Erosion Control Inspection Residential Failed 8/3/2021 08/03/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/03/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
Underslab Plumbing Inspection - Residential Failed 8/3/2021 8/3/2021 08/03/2021
Miscellaneous Correction
Corrective Action Required
08/03/2021
CONNECT INTERIOR DRAIN TILE TO SUMP PUMP
Underslab Plumbing Inspection - Residential Passed 8/11/2021 8/10/2021 08/10/2021
Miscellaneous Correction
Resolved
08/10/2021
Erosion Control Inspection Residential Failed 8/10/2021 08/10/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/03/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/10/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. : MAINTAIN SILT FENCE :
All Rough Inspection - Residential Partial 8/26/2021 8/26/2021 08/26/2021
Misc
Informational
08/26/2021
NO PLANS ON SITE : GARAGE PFH PORTAL FRAME ONLY : - OK TO COVER PORTAL FRAME ONLY - NO TRUSSES SET @ FRONT PORCH OR DECK LEAVE EXPOSED FOR ROUGH IN INSPECTION
All Rough Inspection - Residential Failed 12/7/2021 12/7/2021 12/07/2021
Misc
Informational
08/26/2021
-Provide attic access above garage -Fb garage chase from soffit and roof space; Fb duct/b-vent chase from joist space -Protect wiring at mud room wall top plate -Install joist hanger or other approved device at header joist connection to trimmer joist above duct/b-vent chase -Fill in gap for full support under double lvl beam at laundry/garage wall. -Install 2 stud support underneath double joist at garage chase/closet wall -Install stud support under E1 girder at master closet/garage wall and tie down girder to wall -Fb wall spaces from master bedroom ceiling soffit space; Fb fireplace space from soffit and roof space; Fb floor penetration at traps -Support master ceiling soffit framing at great room/bedroom wall -Nail rear dining corner studs per code -Strap and nail siding of CSPF walls at rear dining per plan -Install missing stud at bedroom 2 bathroom -Nail together girder truss K4; strap down K4 at both ends; Install TJC37 for corner truss in same bedroom -Install missing stud at bedroom 3 closet -Nail girder truss L1 -Nail sheathing to studs at bedroom 4 -Double every other joist under kitchen area -Install missing steel column in basement -Install joist support under duct chase wall -Solid block under office lvl beam (4)2x4 to I beam **OK TO INSULATE
Electrical Service Inspection Passed 12/7/2021 12/7/2021 12/07/2021
Gas Service Inspection - Residential Failed 12/7/2021 12/7/2021 12/07/2021
Misc
Corrective Action Required
12/07/2021
-No pressure
Driveway Inspection Partial 12/9/2021 12/9/2021 12/09/2021
Misc
Informational
12/09/2021
Forms were placed and aggregate was present and compacted. RP 12-9-21
Gas Service Inspection - Residential Failed 12/15/2021 12/15/2021 12/15/2021
Misc
Corrective Action Required
12/07/2021
Pressure only at 5 psi
Erosion Control Inspection Residential Failed 12/15/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/10/2021
12-15-21 -Maintain silt fence at front of lot, clean debris spilled over curb
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
12/15/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. : MAINTAIN SILT FENCE :
All Rough Inspection - Residential Failed 12/15/2021 12/15/2021 12/15/2021
Misc
Informational
12/07/2021
-Fb garage chase from soffit and roof space; Fb duct/b-vent chase from joist space-SEAL ALL GAPS IN AT JOIST SPACE AT CHASE AND COMPLETE FB SOFFIT LINE -Install joist hanger or other approved device at header joist connection to trimmer joist above duct/b-vent chase-BOTH SIDES, chase is non load bearing wall -Fb wall spaces from master bedroom ceiling soffit space; Fb fireplace space from soffit and roof space; Fb floor penetration at traps -Support master ceiling soffit framing at great room/bedroom wall -Install missing steel column in basement-3” COLUMN AT CORNER OF STAIRS, DETAIL TYPE C PER A.3 -Install joist support under duct chase wall -Solid block under office lvl beam (4)2x4 to I beam
Gas Service Inspection - Residential Passed 12/21/2021 12/21/2021 12/21/2021
Misc
Resolved
12/21/2021
Pressure steady at 10 psi
All Rough Inspection - Residential Not Ready 12/21/2021 12/21/2021 12/21/2021
Misc
Informational
12/15/2021
-Fb garage chase from soffit and roof space; Fb duct/b-vent chase from joist space-SEAL ALL GAPS IN AT JOIST SPACE AT CHASE AND COMPLETE FB SOFFIT LINE -Install joist hanger or other approved device at header joist connection to trimmer joist above duct/b-vent chase-BOTH SIDES, chase is non load bearing wall -Fb wall spaces from master bedroom ceiling soffit space; Fb fireplace space from soffit and roof space; -Support master ceiling soffit framing at great room/bedroom wall -Install missing steel column in basement-3” COLUMN AT CORNER OF STAIRS, DETAIL TYPE C PER A.3 -Install joist support under duct chase wall -Solid block under office lvl beam (4)2x4 to I beam
All Rough Inspection - Residential Passed 12/27/2021 12/27/2021 12/27/2021
Misc
Resolved
12/27/2021
Driveway Inspection Failed 12/27/2021 12/27/2021 12/28/2021
Misc
Informational
12/09/2021
Forms were placed and aggregate was present and compacted. RP 12-9-21
Misc
Informational
12/17/2021
Forms and aggregate were still in place, no concrete poured. 12/16/21 ES
Misc
Informational
12/17/2021
Forms and aggregate were still in place, no concrete poured. 12/16/21 ES
Misc
Informational
12/28/2021
Driveway meets LS specs. 12/28/21 ES
Misc
Informational
12/28/2021
Driveway meets LS specs. 12/28/21 ES
Misc
Corrective Action Required
12/28/2021
Previous correction was for wrong address. This driveway is still framed up with water and mud in aggregate now. Will need reinspected when ready to pour. 12/28/21 ES
Plot Plan Inspection Passed 3/9/2022 03/09/2022
Occupancy Inspection - Codes Residential Temporary C of O 3/9/2022 3/9/2022 03/09/2022
Miscellaneous Correction
Corrective Action Required
03/09/2022
DRIVEWAY INSPECTION STILL PENDING PROVIDE SOD PROVIDE SPLASH BLOCKS SUMP SHALL DISCHARGE 36" FROM FOUNDATION
Erosion Control Inspection Residential Failed 3/9/2022 03/09/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/15/2021
12-15-21 -Maintain silt fence at front of lot, clean debris spilled over curb
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
03/09/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. MAINTAIN SILT FENCE UNTIL SOD COMPLETE CLEAN STREET
Driveway Inspection Passed 3/9/2022 3/9/2022 03/09/2022
Misc
Informational
12/28/2021
Forms were placed and aggregate was present and compacted. RP 12-9-21
Misc
Informational
12/28/2021
Forms and aggregate were still in place, no concrete poured. 12/16/21 ES
Misc
Informational
12/28/2021
Forms and aggregate were still in place, no concrete poured. 12/16/21 ES
Misc
Informational
12/28/2021
Driveway meets LS specs. 12/28/21 ES
Misc
Informational
12/28/2021
Driveway meets LS specs. 12/28/21 ES
Misc
Corrective Action Required
12/28/2021
Previous correction was for wrong address. This driveway is still framed up with water and mud in aggregate now. Will need reinspected when ready to pour. 12/28/21 ES
Misc
Informational
03/09/2022
Finished driveway meets LS specs. RP 3-9-22
Occupancy Inspection - Codes Residential Full C of O 3/18/2022 03/18/2022
Miscellaneous Correction
Resolved
03/18/2022
Documents & Images
Date Uploaded File Type Document Name
05/06/2021 139 WOODSIDE RIDGE TRUSS LAYOUT
05/06/2021 LOT 139 FINAL
05/06/2021 W0 #139 - Permit App
05/06/2021 W0 #139 - Valentia - Mediterranean - Sheets- signed
05/06/2021 210371
05/07/2021 Permit Codes Residential Plan Review
05/17/2021 LOT 139 CITY
05/17/2021 Plot Plan APPROVED PLOT PLAN
05/19/2021 Approved Plans APPROVED TRUSS DRAWINGS
05/19/2021 Approved Plans APPROVED TRUSS LAYOUT
05/19/2021 W0 #139 - REVISED ADDRESS - Valentia - Mediterranean - Sheets- signed
05/19/2021 Approved Plans APPROVED PLANS
05/19/2021 Permit Codes Residential Plan Review
05/19/2021 Permit DS Building Permit
05/19/2021 Receipt Receipt for transaction:2021-003174
06/14/2021 Letter INSPECTION SUMMARY
07/28/2021 Letter INSPECTION SUMMARY
08/02/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
08/10/2021 Letter INSPECTION SUMMARY
08/10/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
12/07/2021 Letter INSPECTION SUMMARY
12/07/2021 Letter INSPECTION SUMMARY
12/07/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/15/2021 Letter INSPECTION SUMMARY
12/15/2021 Letter INSPECTION SUMMARY
12/15/2021 Letter INSPECTION SUMMARY
12/21/2021 Letter INSPECTION SUMMARY
12/21/2021 Letter INSPECTION SUMMARY
12/27/2021 Letter INSPECTION SUMMARY
12/28/2021 Letter INSPECTION SUMMARY
12/28/2021 Letter INSPECTION SUMMARY
12/28/2021 Letter INSPECTION SUMMARY
12/28/2021 Letter INSPECTION SUMMARY
03/09/2022 Letter Codes Temporary Certificate of Occupancy
03/09/2022 Letter INSPECTION SUMMARY
03/09/2022 Receipt Receipt for transaction:2022-001265
03/09/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/18/2022 Letter Codes Final Certificate of Occupancy
03/18/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home