Summary
PRRES20212070
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT - COVERED DECK
04/28/2021
04/29/2021
10/25/2021
04/14/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/30/2021 04/29/2021
Brandon Kalwei
As-graded plot plan
Corrective Action Required
04/28/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. need as graded plot plan required in bubble on plot plan
Residential Plan Review Approved 04/30/2021 04/29/2021
Brandon Kalwei
Residential Plan Review Approved 04/30/2021 04/28/2021
Brandon Kalwei
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
04/28/2021

Identify roof covering material (IRC Section R905) Plans show comp roofing, application shows clay/tile roofing. All documents need to match
Plot Plan Review Rejected 04/30/2021 04/28/2021
Brandon Kalwei
As-graded plot plan
Corrective Action Required
04/28/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. need as graded plot plan required in bubble on plot plan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $973.25 $973.25 Paid 04/29/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 04/29/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/29/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/29/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/29/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/29/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 03/16/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 03/16/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/21/2021 05/21/2021
Misc
Informational
05/21/2021
3RD PARTY FOOTING BY COLBY SHAW AT EVERSTEAD SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED NEAR THE CENTER OF REAR GARAGE FOUNDATION WALL
Underslab Plumbing Inspection - Residential Passed 6/17/2021 6/17/2021 06/17/2021
Sewer Service Inspection - R Passed 6/21/2021 06/21/2021
Water Service Inspection - R Passed 6/25/2021 (1:45) 6/25/2021 06/25/2021
All Rough Inspection - Residential Failed 9/23/2021 9/23/2021 09/23/2021
Miscellaneous Correction
Corrective Action Required
09/23/2021
- FRONT PORCH PROVIDE ENGINEERS LETTER ADDRESSING FIELD MODIFICATIONS TO TRUSSES E3,E4,E5, - - COVERED DECK APPRROVED OK TO COVER - - PFH PORTAL FRAME GARAGE NAIL TOP PLATE TO HEADER PER PLANS (2) ROWS 16D SINKERS 3" O.C. CHECK ON ROUGH IN, OK TO COVER EXTERIOR
Piers/Caissons Inspection - Residential Failed 10/21/2021 (1:45) 10/21/2021 10/21/2021
Miscellaneous Correction
Corrective Action Required
10/21/2021
PLANS CALL FOR (2) 24 X 36 COVERED DECK PIERS THESE ARE 16 X 33
Piers/Caissons Inspection - Residential Failed 10/25/2021 (1:00) 10/25/2021 10/25/2021
Miscellaneous Correction
Corrective Action Required
10/21/2021
PLANS CALL FOR (2) 24 X 36 COVERED DECK PIERS SYMBOL K ISOLATED FOOTINGS AND COLUMN PADS SCHEDULE THESE ARE 16 X 33 19X35 ON 10/25/21
Driveway Inspection Partial 11/3/2021 11/3/2021 11/03/2021
Misc
Informational
11/03/2021
Driveway is framed and has 4” of aggregate in place and compacted. Meets LS and ADA spec. 11/3 ES
Driveway Inspection Passed 11/12/2021 11/12/2021 11/12/2021
Misc
Informational
11/03/2021
Driveway is framed and has 4” of aggregate in place and compacted. Meets LS and ADA spec. 11/3 ES
Misc
Informational
11/12/2021
Driveway meets LS and ADA spec. 11/12 ES
Sidewalk Inspection Partial 11/23/2021 11/23/2021
Misc
Informational
11/23/2021
Sidewalk was framed up with aggregate in and compacted.11/23 ES
All Rough Inspection - Residential Not Ready 12/2/2021 12/2/2021 12/02/2021
Miscellaneous Correction
Corrective Action Required
09/23/2021
- FRONT PORCH PROVIDE ENGINEERS LETTER ADDRESSING FIELD MODIFICATIONS TO TRUSSES E3,E4,E5, - - COVERED DECK APPRROVED OK TO COVER - - PFH PORTAL FRAME GARAGE NAIL TOP PLATE TO HEADER PER PLANS (2) ROWS 16D SINKERS 3" O.C. CHECK ON ROUGH IN, OK TO COVER EXTERIOR
Misc
Corrective Action Required
12/02/2021
PROVIDE CITY STAMPED PLANS ON SITE FOR INSPECTION.
Sidewalk Inspection Passed 12/3/2021 12/3/2021 12/03/2021
Misc
Informational
11/23/2021
Sidewalk was framed up with aggregate in and compacted.11/23 ES
Misc
Informational
12/03/2021
Sidewalk meets LS and ADA specs. RP 12-3-21
Electrical Service Inspection Passed 12/3/2021 12/3/2021 12/03/2021
Gas Service Inspection - Residential Failed 12/3/2021 12/3/2021 12/03/2021
Miscellaneous Correction
Corrective Action Required
12/03/2021
PROVIDE MIN 10 PSI FOR 15 MINUTES
All Rough Inspection - Residential Failed 12/3/2021 12/3/2021 12/03/2021
Miscellaneous Correction
Corrective Action Required
12/02/2021
- FRONT PORCH PROVIDE ENGINEERS LETTER ADDRESSING FIELD MODIFICATIONS TO TRUSSES E3,E4,E5, - - COVERED DECK APPRROVED OK TO COVER -
Misc
Corrective Action Required
12/02/2021
PROVIDE Repairs to trusses front porch per engineers letter Provide protection NM conductors coach lights garage at lvl Anchor bolts shall be in middle 1/3 the width of plate in garage Address notched trusses master closet/Garage wall Strap top plate above front door no overlap Provide 4 studs at girder truss bearing points laundry room Nail stud to bottom plate under stairs near SCH 40 column Tighten anchor bolts basement nail exterior wall sheathing per code 6" edge 12" field
All Rough Inspection - Residential Not Ready 12/14/2021 12/14/2021 12/14/2021
Miscellaneous Correction
Corrective Action Required
12/03/2021
- FRONT PORCH PROVIDE ENGINEERS LETTER ADDRESSING FIELD MODIFICATIONS TO TRUSSES E3,E4,E5, - - COVERED DECK APPRROVED OK TO COVER -
Misc
Corrective Action Required
12/03/2021
PROVIDE Repairs to trusses front porch per engineers letter Address notched trusses master closet/Garage wall Tighten anchor bolts basement nail exterior wall sheathing per code 6" edge 12" field
Gas Service Inspection - Residential Passed 12/14/2021 12/14/2021 12/14/2021
Miscellaneous Correction
Resolved
12/14/2021
All Rough Inspection - Residential Passed 12/20/2021 12/20/2021 12/20/2021
Miscellaneous Correction
Resolved
12/20/2021
- COVERED DECK APPRROVED OK TO COVER -
Misc
Resolved
12/20/2021
Plot Plan Inspection Failed 3/15/2022 03/15/2022
Misc
Corrective Action Required
03/15/2022
SUBMIT AS GRADED PLOT PLAN
Erosion Control Inspection Residential Failed 3/15/2022 03/15/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/15/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE UNTIL SOD COMPLETE CLEAN STREET
Occupancy Inspection - Codes Residential Failed 3/15/2022 3/15/2022 03/15/2022
Miscellaneous Correction
Corrective Action Required
03/15/2022
Submit as graded plot plan Obtain lawn irrigation permit & submit back flow certification Deck pier inspection failed 18" plan calls for 24" diameter Pay not ready fees Provide sod & splash blocks Provide guardrail front porch over 30" to grade Replace broken tread garage steps Provide cover for attic access garage Provide concrete landing at deck stairs Provide anti siphon device at water shut off Sump shall discharge 36" from foundation Sewer tracer wire in a box at grade level
Plot Plan Inspection Failed 3/31/2022 03/31/2022
Misc
Corrective Action Required
03/15/2022
UNCOVER AND RAISE TO GRADE IF NECESSARY MANHOLE MH 2-6 AT REAR OF LOT AS SHOWN ON PLOT PLAN
Plot Plan Inspection Passed 4/14/2022 04/14/2022
Misc
Resolved
04/14/2022
UNCOVER AND RAISE TO GRADE IF NECESSARY MANHOLE MH 2-6 AT REAR OF LOT AS SHOWN ON PLOT PLAN
Piers/Caissons Inspection - Residential Passed 4/14/2022 04/14/2022
Miscellaneous Correction
Corrective Action Required
10/25/2021
PLANS CALL FOR (2) 24 X 36 COVERED DECK PIERS SYMBOL K ISOLATED FOOTINGS AND COLUMN PADS SCHEDULE THESE ARE 16 X 33 19X35 ON 10/25/22 ENGINEERS LETTER ADDRESSING PIERS LOADED TO PERMIT
Occupancy Inspection - Codes Residential Full C of O 4/14/2022 4/14/2022 04/14/2022
Miscellaneous Correction
Resolved
04/14/2022
Documents & Images
Date Uploaded File Type Document Name
04/28/2021 49 WOODSIDE RIDGE ROOF LAYOUT
04/28/2021 LOT 49 FINAL
04/28/2021 210382
04/28/2021 W2 #49 - Carbondale - Farmhouse - Sheets- signed
04/28/2021 Approved Plans APPROVED TRUSS DRAWINGS
04/28/2021 Approved Plans APPROVED TRUSS LAYOUT
04/28/2021 Letter Codes Residential Plan Review
04/28/2021 Application Form APPLICATION
04/28/2021 Approved Plans APPROVED PLANS
04/28/2021 LOT 49 CITY
04/28/2021 Plot Plan APPROVED PLOT PLAN
04/29/2021 Receipt Receipt for transaction:2021-002326
04/29/2021 Letter DS Building Permit
05/21/2021 Lot 49 Woodside Ridge Footing Inspection
05/21/2021 Letter INSPECTION SUMMARY
06/17/2021 Letter INSPECTION SUMMARY
06/21/2021 Letter INSPECTION SUMMARY
06/25/2021 Letter INSPECTION SUMMARY
09/23/2021 Letter INSPECTION SUMMARY
10/25/2021 Letter INSPECTION SUMMARY
10/25/2021 Letter INSPECTION SUMMARY
11/03/2021 Letter INSPECTION SUMMARY
11/12/2021 Letter INSPECTION SUMMARY
11/23/2021 Letter INSPECTION SUMMARY
12/01/2021 WO 49 truss fixes
12/02/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
12/13/2021 Letter INSPECTION SUMMARY
12/14/2021 Letter INSPECTION SUMMARY
12/14/2021 Letter INSPECTION SUMMARY
12/17/2021 Truss repair for master closet
12/20/2021 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/16/2022 Receipt Receipt for transaction:2022-001426
03/21/2022 49 woodside ridge pier letter
03/30/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
03/31/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter Field Certificate of Occupancy
04/14/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents