Permit Application Status

PRRES20212062


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212062
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK TILE ROOF
04/27/2021
05/04/2021
06/20/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
MIKE@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/30/2021 04/28/2021
Kim Brennan
Planning Review (RES) Approved 04/30/2021 04/28/2021
Shannon McGuire
Residential Plan Review Approved 04/30/2021 04/28/2021
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $993.98 $993.98 Paid 04/28/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/28/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/28/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 04/28/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/28/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/28/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 02/14/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 03/14/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 06/03/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/28/2021 06/28/2021
Misc
Informational
06/28/2021
3RD PARTY FOOTING BY DEREK PEREZ @ EVERSTEAD SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED CENTER LEFT OF SOUTH (REAR) GARAGE FOUNDATION WALL
Underslab Plumbing Inspection - Residential Passed 8/12/2021 8/11/2021 08/11/2021
Sewer Service Inspection - R Passed 9/7/2021 (1:30) 9/7/2021 09/07/2021
Water Service Inspection - R Passed 9/9/2021 09/09/2021
Gas Service Inspection - Residential Failed 1/31/2022 1/31/2022 01/31/2022
Miscellaneous Correction
Corrective Action Required
01/31/2022
Complete gas piping and shut off at fireplace
Erosion Control Inspection Residential Failed 2/11/2022 02/11/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/11/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER CLEAN STREET
All Rough Inspection - Residential Not Ready 2/11/2022 2/11/2022 02/11/2022
Miscellaneous Correction
Corrective Action Required
02/11/2022
THIS HOUSE IS NOT READY NO INSPECTION THIS LIST IS INCOMPLETE AND MAY BE ADDED TO AS TRADES COMPLETE WORK COMPLETE BELOW ITEMS BEFORE RESCHEDULING Furr out B vent & fire block rear of garage Solid block top plate to roof deck & seal gaps east & west walls (per 2018 IRC SECTION 302 ) Complete fireplace vent to roof Tighten anchor bolts garage & basement Anchor bolts shall be in middle 1/3 the width of plate Provide 4 stud pack at girder truss bearing points per plan Hook up & Shield gas line at fire place Provide attic access per plans Seal upward penetrations throughout Provide interior LIB bracing per plans Provide CS-PF exterior bracing at great room per plans Nail intersecting wall corners per plan Solid block and nail sheathing breaks per code Nail exterior wall sheathing per code Provide anchor bolts SCH 40 columns basement
Erosion Control Inspection Residential Failed 2/23/2022 02/23/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/11/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER CLEAN STREET
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/23/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. CLEAN STREET
Electrical Service Inspection Passed 2/23/2022 02/23/2022
Gas Service Inspection - Residential Failed 2/23/2022 02/23/2022
Miscellaneous Correction
Resolved
02/23/2022
PROVIDE MINIMUM 10 PSI FOR 15 MINUTES FOR GAS TEST @ 0 PSI 2/23/22
Miscellaneous Correction
Corrective Action Required
02/23/2022
PROVIDE MINIMUM 10 PSI FOR 15 MINUTES FOR GAS TEST @ 0 PSI 2/23/22
All Rough Inspection - Residential Failed 2/23/2022 2/23/2022 02/23/2022
Miscellaneous Correction
Corrective Action Required
02/11/2022
Provide 4 stud pack at girder truss bearing points per plan ( not done) Provide CS-PF exterior bracing at great room per plans ( 2018 IRC FIGURE R602.10.6.4 not done) Nail intersecting wall corners per plan ( not done) 2/23/22 Secure gas line at fireplace Address over notched girder stud pack at laundry room Complete shower drain master Nail exterior wall sheathing under bath 2 window Fire block tub trap bath 2 Nail LIBs throughout 2 nails top & bottom plate & intersecting studs Provide H2.5s / trusslock in each girder truss dining room & master bed Provide solid blocking between joist of kitchen island above per plan Provide (3) 2x6 under beam at patio SGD per plan Provide additional studs for full bearing of stud pack above west of sgd per plan
All Rough Inspection - Residential Failed 3/10/2022 3/10/2022 03/10/2022
Miscellaneous Correction
Corrective Action Required
02/23/2022
Provide CS-PF exterior bracing at great room per plans ( 2018 IRC FIGURE R602.10.6.4 not done), exterior sheathing and nailing per design Address over notched girder stud pack at laundry room Complete shower drain master Provide (3) 2x6 under beam at patio SGD per plan
Gas Service Inspection - Residential Passed 3/10/2022 3/10/2022 03/10/2022
Miscellaneous Correction
Resolved
03/10/2022
PROVIDE MINIMUM 10 PSI FOR 15 MINUTES FOR GAS TEST @ 0 PSI 2/23/22
All Rough Inspection - Residential Not Ready 3/14/2022 3/14/2022 03/14/2022
Miscellaneous Correction
Corrective Action Required
03/10/2022
Provide CS-PF exterior bracing at great room per plans ( 2018 IRC FIGURE R602.10.6.4 not done), exterior sheathing and nailing per design ( 3" nailing pattern not done ) Address over notched girder stud pack at laundry room ( studs still notched ) Complete shower drain master Provide (3) 2x6 under beam at patio SGD per plan (not done)
All Rough Inspection - Residential Passed 3/15/2022 3/15/2022 03/15/2022
Miscellaneous Correction
Resolved
03/15/2022
Driveway Inspection Partial 4/13/2022 4/13/2022 04/13/2022
Misc
Informational
04/13/2022
Forms were placed and aggregate was present and compacted. RP 4-13-22
Sidewalk Inspection Partial 4/13/2022 4/13/2022 04/13/2022
Misc
Informational
04/13/2022
Forms were placed and aggregate was present and compacted. Had them adjust the forms around the curb inlet because they were out of tolerance. RP 4-13-22
Sidewalk Inspection Failed 4/22/2022 4/22/2022 04/22/2022
Misc
Informational
04/13/2022
Forms were placed and aggregate was present and compacted. Had them adjust the forms around the curb inlet because they were out of tolerance. RP 4-13-22
Misc
Corrective Action Required
04/22/2022
Sidewalk covered with silt. Need to clean off before final inspection for compliance. RP 4-22-22
Driveway Inspection Passed 4/22/2022 4/22/2022 04/22/2022
Misc
Informational
04/13/2022
Forms were placed and aggregate was present and compacted. RP 4-13-22
Misc
Informational
04/22/2022
Finished driveway meets LS and ADA specs. RP 4-22-22
Sidewalk Inspection Failed 4/29/2022 4/29/2022 05/10/2022
Misc
Informational
04/22/2022
Forms were placed and aggregate was present and compacted. Had them adjust the forms around the curb inlet because they were out of tolerance. RP 4-13-22
Misc
Corrective Action Required
04/22/2022
Sidewalk covered with silt. Need to clean off before final inspection for compliance. RP 4-22-22
Misc
Corrective Action Required
05/10/2022
Sidewalk has a busted panel that needs replaced. The rest of the sidewalk meets LS and ADA specs. 5/10/22 ES
Sidewalk Inspection Failed 5/20/2022 5/20/2022 05/23/2022
Misc
Informational
05/10/2022
Forms were placed and aggregate was present and compacted. Had them adjust the forms around the curb inlet because they were out of tolerance. RP 4-13-22
Misc
Corrective Action Required
05/10/2022
Sidewalk covered with silt. Need to clean off before final inspection for compliance. RP 4-22-22
Misc
Corrective Action Required
05/10/2022
Sidewalk has a busted panel that needs replaced. The rest of the sidewalk meets LS and ADA specs. 5/10/22 ES Panel still hasn’t been replaced. 5/23/22 ES
Occupancy Inspection - Codes Residential Failed 6/2/2022 6/2/2022 06/02/2022
Miscellaneous Correction
Corrective Action Required
06/02/2022
- Final grading and sod - Splash blocks - Sump discharge minimum is 36” away from foundation - Install irrigation system - Sidewalk inspection pending - Pay all fees - Maintain erosion control - Uncover smoke detectors - Missing outlet covers through out - No lock or secondary lock on sliding door - Label all non GFCI outlets - Provide lock and secondary lock for sliding door basement
Occupancy Inspection - Codes Residential Failed 6/6/2022 6/6/2022 06/06/2022
Miscellaneous Correction
Corrective Action Required
06/02/2022
- Final grading and sod - Splash blocks - Sump discharge minimum is 36” away from foundation - Install irrigation system - Sidewalk inspection pending - Maintain erosion control - Uncover smoke detectors - Missing outlet covers through out
Sidewalk Inspection Passed 6/6/2022 6/6/2022 06/06/2022
Misc
Informational
05/23/2022
Forms were placed and aggregate was present and compacted. Had them adjust the forms around the curb inlet because they were out of tolerance. RP 4-13-22
Misc
Resolved
06/06/2022
Sidewalk covered with silt. Need to clean off before final inspection for compliance. RP 4-22-22
Misc
Resolved
06/06/2022
Sidewalk has a busted panel that needs replaced. The rest of the sidewalk meets LS and ADA specs. 5/10/22 ES Panel still hasn’t been replaced. 5/23/22 ES 2 busted sidewalk panels were replaced. Sidewalk meets LS and ADA specs. 6/6/22 ES
Piers/Caissons Inspection - Residential Passed 6/7/2022 06/07/2022
Misc
Informational
06/07/2022
Inspection done by third party
Occupancy Inspection - Codes Residential Temporary C of O 6/7/2022 6/7/2022 06/07/2022
Miscellaneous Correction
Corrective Action Required
06/06/2022
- Final grading and sod - Splash blocks - Sump discharge minimum is 36” away from foundation - Install irrigation system - Sidewalk inspection pending - Maintain erosion control
Erosion Control Inspection Residential Failed 6/7/2022 06/07/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/07/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER CLEAN STREET
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/23/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. CLEAN STREET PUT IN SWADDLES
Plot Plan Inspection Passed 6/20/2022 06/20/2022
Erosion Control Inspection Residential Passed 6/20/2022 06/20/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/20/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. CLEAN STREET PUT IN SWADDLES
Occupancy Inspection - Codes Residential Full C of O 6/20/2022 6/20/2022 06/20/2022
Miscellaneous Correction
Resolved
06/20/2022
Documents & Images
Date Uploaded File Type Document Name
04/27/2021 Application Form Permit Application and License Tax Form
04/28/2021 Approved Plans Approved Truss Layout
04/28/2021 Approved Plans Approved Truss Package
04/28/2021 Receipt Receipt for transaction:2021-002278
05/04/2021 Permit DS Building Permit
05/06/2021 Plot Plan Approved Plot Plan
05/06/2021 Approved Plans Approved Drawings
05/06/2021 Letter DS Building Permit
06/24/2021 W1-23 Woodside Ridge Footing inspection
06/28/2021 W1-23 Woodside Ridge Footing inspection
06/28/2021 Letter INSPECTION SUMMARY
08/11/2021 Letter INSPECTION SUMMARY
09/07/2021 Letter INSPECTION SUMMARY
09/09/2021 Letter INSPECTION SUMMARY
01/31/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/14/2022 Receipt Receipt for transaction:2022-000802
02/23/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
03/10/2022 Letter INSPECTION SUMMARY
03/10/2022 Letter INSPECTION SUMMARY
03/14/2022 Letter INSPECTION SUMMARY
03/14/2022 Receipt Receipt for transaction:2022-001353
03/15/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
06/02/2022 Letter INSPECTION SUMMARY
06/03/2022 Receipt Receipt for transaction:2022-004286
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter Codes Temporary Certificate of Occupancy
06/07/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter Codes Final Certificate of Occupancy
06/20/2022 Letter Field Certificate of Occupancy
06/20/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home