Permit Application Status

PRRES20211915


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211915
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - UNFINISHED BASEMENT
04/20/2021
04/28/2021
10/25/2021
03/21/2022
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
CURTIS@SABHOMES.COM  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/30/2021 04/28/2021
Kim Brennan
Residential Plan Review Approved 04/30/2021 04/28/2021
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
04/28/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) no smoke/co detector located on 2nd level.
Plot Plan Review Approved 04/23/2021 04/23/2021
Brandon Kalwei
Lot elevations
Corrective Action Required
04/21/2021

Existing and finish elevations at all property corners must be provided on the plot plan. missing at SW corner.
Residential Plan Review Rejected 04/23/2021 04/21/2021
Brandon Kalwei
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
04/21/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) no smoke/co detector located on 2nd level.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,288.22 $1,288.22 Paid 04/28/2021
8331507-Sewer Connection Fee $480.00 $480.00 Paid 04/28/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/28/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/28/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/28/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/28/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 6/8/2021 6/8/2021 06/08/2021
Erosion Control Inspection Residential Failed 1/20/2022 06/08/2021
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/08/2021
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Water Service Inspection - R Partial 6/9/2021 6/9/2021 06/09/2021
Misc
Corrective Action Required
06/09/2021
-Partial only- PEX from Southwest corner 15' toward meter pit
Sewer Service Inspection - R Passed 6/9/2021 (3:30) 6/9/2021 06/09/2021
Water Service Inspection - R Passed 6/10/2021 (1:00) 6/10/2021 06/10/2021
Misc
Resolved
06/10/2021
-Partial only- PEX from Southwest corner 15' toward meter pit : complete Michael Harkins 06/10/2021 12:52 PM :
Piers/Caissons Inspection - Residential Passed 7/13/2021 07/13/2021
Gas Service Inspection - Residential Failed 9/21/2021 9/21/2021 09/21/2021
Misc
Corrective Action Required
09/21/2021
SHUTOFF REQUIRED AT FUTURE PATIO GAS, SEAL ENDS OF PIPE TO PREVENT CONCRETE FROM ENTERING
Electrical Service Inspection Passed 9/21/2021 9/21/2021 09/21/2021
All Rough Inspection - Residential Failed 9/21/2021 9/21/2021 09/21/2021
Misc
Corrective Action Required
09/21/2021
-Add joist hangers at header garage sgl car over 4’ -Header off cut joist at garage for DWV -seal penetrations at top plate garage, kitchen -Nail protection plates at NM garage less than 1 1/4” from end of stud -Fireblock deadspace garage entry -lower bath exhaust fan at 1st floor 1/2 bath to ceiling height -2x4 turned flat at furred down 3’ or more must be connected to floor joist above to support the ceiling load -Shield electrical boxes at air return -Great room air return, pan off return air open to furred down space and remove solid blocking between studs to allow air return to function -Fireblock all tub and shower traps -seal all penetrations through air returns -(4) 1 3/4” x 9 1/4” LVL joists at garage (2) locations per plans -Seal pex penetrations through air return at basement -Anchor all SCH 40 steel columns at basement
Gas Service Inspection - Residential Passed 9/24/2021 09/24/2021
Misc
Resolved
09/24/2021
SHUTOFF REQUIRED AT FUTURE PATIO GAS, SEAL ENDS OF PIPE TO PREVENT CONCRETE FROM ENTERING
All Rough Inspection - Residential Failed 9/24/2021 09/24/2021
Misc
Corrective Action Required
09/21/2021
-Maintain silt fence and clean silt and debris storm inlet -Nail protection plates at NM garage less than 1 1/4” from end of stud -(4) 1 3/4” x 9 1/4” LVL joists at garage (2) locations per plans **OK to insulate
All Rough Inspection - Residential Passed 10/4/2021 10/4/2021 10/04/2021
Misc
Resolved
10/04/2021
-Maintain silt fence and clean silt and debris storm inlet -Nail protection plates at NM garage less than 1 1/4” from end of stud -(4) 1 3/4” x 9 1/4” LVL joists at garage (2) locations per plans **OK to insulate
Driveway Inspection Passed 12/2/2021 12/2/2021 12/03/2021
Misc
Informational
12/02/2021
On Thursday 12/2/2021 I performed a driveway inspection and pass the subgrade to pour concrete
Occupancy Inspection - Codes Residential Failed 12/28/2021 12/28/2021 12/28/2021
Miscellaneous Correction
Corrective Action Required
12/28/2021
- Submit as graded plot plan - Sidewalk and driveway inspection pending - gutters and down spouts - Final grading and sod - Splash blocks - Obtain irrigation permit and submit back flow certification - Maintain erosion control until sod is in place - Provide ladder for egress window basement - Complete A/C disconnect
Erosion Control Inspection Residential Failed 12/28/2021 12/28/2021
Misc
Corrective Action Required
06/08/2021
-Erosion control requires continuous maintenance. Until sod is done -immediate street cleanup required -remove debris from storm water inlet
Occupancy Inspection - Codes Residential Temporary C of O 1/3/2022 1/3/2022 01/03/2022
Miscellaneous Correction
Corrective Action Required
12/28/2021
- Sidewalk and driveway inspection pending - Final grading and sod - Splash blocks - submit back flow certification - Maintain erosion control until sod is in place -Handrail required at front entry stairs
Erosion Control Inspection Residential Failed 1/3/2022 01/03/2022
Misc
Corrective Action Required
12/28/2021
-Erosion control requires continuous maintenance. Until sod is done - place swaddle until sod
Sidewalk Inspection Passed 12/3/2021 12/3/2021 01/10/2022
Misc
Informational
12/03/2021
On Friday 12/3/2021 I performed a sidewalk inspection and pass the subgrade to pour concrete
Erosion Control Inspection Residential Failed 1/20/2022 01/20/2022
Misc
Corrective Action Required
01/03/2022
MAINTAIN EROSION CONTROL UNTIL SOD IS IN PLACE
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/20/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Footing Inspection - Residential Passed 3/21/2022 03/21/2022
Misc
Corrective Action Required
03/21/2022
third party footing inspection performed.
Plot Plan Inspection Passed 3/21/2022 03/21/2022
Erosion Control Inspection Residential Passed 3/21/2022 03/21/2022
Misc
Corrective Action Required
01/20/2022
MAINTAIN EROSION CONTROL UNTIL SOD IS IN PLACE
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/20/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Full C of O 3/21/2022 3/21/2022 03/21/2022
Miscellaneous Correction
Resolved
03/21/2022
- Sidewalk and driveway inspection pending - Final grading and sod - Splash blocks - submit back flow certification - Maintain erosion control until sod is in place -hand rail required at front entry stairs
Driveway Inspection Passed 1/10/2022 1/10/2022 04/13/2022
Misc
Informational
12/02/2021
On Thursday 12/2/2021 I performed a driveway inspection and pass the subgrade to pour concrete
Sidewalk Inspection Passed 1/10/2022 1/10/2022 07/12/2022
Misc
Informational
12/03/2021
On Friday 12/3/2021 I performed a sidewalk inspection and pass the subgrade to pour concrete. 7.12.2022 sidewalk appears to be in compliance.
Documents & Images
Date Uploaded File Type Document Name
04/20/2021 Application Form APPLICATION
04/20/2021 Application Form excise tax
04/20/2021 E718 - Final Engineered Plans 4_20_21
04/21/2021 Letter Codes Residential Plan Review
04/23/2021 E718 - Revised Plot Plan 4_23_21
04/28/2021 Receipt Receipt for transaction:2021-002318
04/28/2021 Letter DS Building Permit
05/14/2021 M L Crose 2366 SW Old Port Rd LSMO Eagle Creek Lot 718 SAB Permit 2021-1915 3rd Party Footing Inspection Report 5-13-21
05/17/2021 Letter INSPECTION SUMMARY
06/08/2021 Letter INSPECTION SUMMARY
06/08/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter INSPECTION SUMMARY
06/10/2021 Letter INSPECTION SUMMARY
07/13/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
09/28/2021 Approved Plans approved plans
10/04/2021 Letter INSPECTION SUMMARY
12/02/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
12/13/2021 Letter INSPECTION SUMMARY
12/28/2021 Plot Plan APPROVED PLOT PLAN
12/28/2021 Letter INSPECTION SUMMARY
12/28/2021 Letter INSPECTION SUMMARY
01/03/2022 Letter Codes Temporary Certificate of Occupancy
01/03/2022 Letter INSPECTION SUMMARY
01/10/2022 Letter INSPECTION SUMMARY
01/10/2022 Letter INSPECTION SUMMARY
01/10/2022 Letter INSPECTION SUMMARY
01/20/2022 Letter INSPECTION SUMMARY
03/21/2022 Letter INSPECTION SUMMARY
03/21/2022 Letter INSPECTION SUMMARY
03/21/2022 Letter INSPECTION SUMMARY
03/21/2022 Letter Field Certificate of Occupancy
03/21/2022 Letter Codes Final Certificate of Occupancy
04/13/2022 Letter INSPECTION SUMMARY
07/12/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: