Permit Application Status

PRRES20211818


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211818
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT
04/15/2021
05/14/2021
10/13/2021
06/23/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DUSTIN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/18/2021 05/14/2021
Kim Brennan
Property boundary
Corrective Action Required
05/14/2021

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. The bearings in the front and the rear are not consistent with the recorded plat
Residential Plan Review Approved 05/18/2021 05/14/2021
Kim Brennan
Misc
Corrective Action Required
05/14/2021

Property address must be on all pages of the drawings
07 Identify emergency escape openings from bedrooms
Corrective Action Required
05/14/2021

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) Please identify for bedroom #2.
Plot Plan Review Rejected 04/19/2021 04/16/2021
Kim Brennan
Property boundary
Corrective Action Required
04/16/2021

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. The bearings in the front and the rear are not consistent with the recorded plat
Residential Plan Review Rejected 04/19/2021 04/15/2021
Kim Brennan
Misc
Corrective Action Required
04/15/2021

Property address must be on all pages of the drawings
07 Identify emergency escape openings from bedrooms
Corrective Action Required
04/20/2021

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) Please identify for bedroom #2.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,497.93 $1,497.93 Paid 05/14/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/14/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/14/2021
8331504-EFHB Middle Big Creek, Full $703.08 $703.08 Paid 05/14/2021
8331507-Sewer Connection Fee $630.00 $630.00 Paid 05/14/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 05/14/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 05/14/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/09/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/09/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/09/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $100.00 $100.00 Paid 06/09/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/09/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/6/2021 8/6/2021 08/06/2021
Misc
Informational
08/06/2021
APPROVED PER BRADLEY HUXOL 6/18/21
Underslab Plumbing Inspection - Residential Passed 8/6/2021 8/6/2021 08/06/2021
All Rough Inspection - Residential Not Ready 1/25/2022 1/25/2022 01/25/2022
Misc
Corrective Action Required
01/25/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
All Rough Inspection - Residential Not Ready 1/27/2022 1/27/2022 01/27/2022
Misc
Resolved
01/27/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
Misc
Corrective Action Required
01/27/2022
-furr downs not complete 1st and 2nd floor -fire stoping though out -electrical not in complete -plumbing supports -lib’s not to code -fire places not install -csst not supported properly -due to to many items not in compliance inspection not ready
Electrical Service Inspection Passed 2/3/2022 2/3/2022 02/03/2022
All Rough Inspection - Residential Failed 2/3/2022 2/3/2022 02/03/2022
Misc
Corrective Action Required
01/27/2022
-Garage PFH panel splices must occur within the middle 24” of the portal leg -overnotched studs at anchor bolts dbl door garage wall -fireblock plumbing chase at garage -fireblock at garage wall seal all annual spaces around plumbing and electrical -fireblock HVAC penetration to rim joist at garage -Fireblock vertical to horizontal at HVAC bump out garage wall -address floor joist cut for DWV at furred down garage -Fireblock all tub and shower traps -address overnotched floor joist west side of garage at furred down -attic access at garage -H2.5 or equivalent at all truss ends garage -address dbl top plate removed for HVAC at garage load bearing wall -fireblock Mechanical plumbing chase garage/kitchen -header and add joist hangers per code to floor joists cut for HVAC at chase kitchen, floor joists currently supported by non load bearing walls -add joist hangers at joist to beam connection above fridge kitchen, joists cannot be supported by non load bearing wall -add stud shoe 1st floor bath exterior wall -add bocca plate at DWV furred down soffit line 1st floor bath -vent all bath exhaust fans to exterior -Fireblock all tub traps -add structural straps to top plates bored 50% or more all exterior walls and all interior load bearing walls, straps must min 1 1/2” wide, 16 gauge, extend 6” each side passed the bored and include (4) 10D nails each side of straps -solid block between joists at all cantilevers -seal all top and bottom plate penetrations at kitchen -dbl top plate requires min 24” offset between plate breaks - see kitchen, master bed/closet -fireblock chases at great room windows -fireblock vertical to horizontal at case to furred down great room windows -secure CSST gas line at great room chase per manufacture requirements -Install fireplace -complete gas lines, pressure test required after completion of all gas lines -address dbl joist/top plate removed for HVAC at dining room/garage wall, plans show this as non load bearing wall -Nail exterior sheathing for CS-PF at dining room windows per plans/IRC 602.10.6.4 -secure all vertical DWV 2” or less at mid point -(2) 2x4 trimmer studs at kitchen wall headers per plans -king stud missing at kitchen breakfast window header -(3) 2x10 joists at great room per plans -address 2x4 to 2x6 top plate connection at 2nd floor stairs SW corner -solid block all sheathing breaks -Fireblock deadspace bedroom#3/master bed corner -Protect all NM within 6’ of attic -add studs shoes master bath exterior studs bored for DWV -(4) 2X stud packs at each girder truss bearing end per plans -missing stud at master bed mech chase wall -address top plate to top plate connection as required by code at corner bed#2/bath#2 -all truss lateral bracing per plans -fur out at stair wall for sump pump discharge line -gas line bond required -add joist hangers to stair landing joists, 4’ -add joist hangers to sgl joist connection at fireplace cantilever basement -(3) 2x10 joists at fireplace cantilever per plans -3.5” SCH 40 steel column at pier location “E” basement per plans -address overnotched floor joists for anchor bolts at basement sill plate for garage wall, not enough bearing on plate as required by code DUE TO CONDITIONS NO INSPECTION PERFORMED ON EXTERIOR ITEMS LIST INCOMPLETE AND SUBJECT TO CHANGE FYI THIS HOUSE WAS NOT READY FOR AN INSPECTION, THIS IS NOT AN ACCEPTABLE AMOUNT OF CORRECTIONS
Gas Service Inspection - Residential Failed 2/15/2022 2/15/2022 02/15/2022
Misc
Corrective Action Required
02/15/2022
-GAS LINE BOND REQUIRED PRESSURE OK
All Rough Inspection - Residential Failed 2/15/2022 2/15/2022 02/15/2022
Misc
Corrective Action Required
02/03/2022
-overnotched studs at anchor bolts dbl door garage wall -fireblock plumbing chase at garage, if using loose insulation it needs to be filled and packed tight -Fireblock vertical to horizontal at HVAC bump out garage wall -address dbl top plate removed for HVAC at garage load bearing wall(nail straps off) -header and add joist hangers per code to floor joists cut for HVAC at chase kitchen, floor joists currently supported by non load bearing walls (the header needs to be connected to adjacent floor joists to distribute load of joists, the header is still resting on a non load bearing wall and all joists need joists hangers at 4’) -fireblock floor penetration for HVAC at chase kitchen -solid block between joists at all cantilevers, see dining room cantilever -seal all bottom plate penetrations at kitchen -fireblock chases at great room windows -fireblock vertical to horizontal at chase to furred down great room windows -secure CSST gas line at great room chase per manufacture requirements -address dbl joist/top plate removed for HVAC at dining room/garage wall, plans show this as non load bearing wall (nail sister to joist per engineer letter) -secure all vertical DWV 2” or less at mid point -add studs shoes master bath exterior studs bored for DWV -gas line bond required -seal gas line penetration at patio fireplace lid -fireblock between studs at patio fireplace lid -secure CSST gas lines through covered patio attic space per manufacture installation requirements
All Rough Inspection - Residential Not Ready 2/24/2022 2/24/2022 02/24/2022
Misc
Corrective Action Required
02/15/2022
-overnotched studs at anchor bolts dbl door garage wall -complete HVAC duct removed during fireblock at garage furred down -header and add joist hangers per code to floor joists cut for HVAC at chase kitchen, floor joists currently supported by non load bearing walls (the header needs to be connected to adjacent floor joists to distribute load of joists, the header is still resting on a non load bearing wall and all joists need joists hangers at 4’) -fireblock floor penetration for HVAC at chase kitchen -solid block between joists at all cantilevers, see dining room cantilever -seal all bottom plate penetrations at kitchen -fireblock chases at great room windows -fireblock vertical to horizontal at chase to furred down great room windows -seal gas line penetration at patio fireplace lid, fireplace covered at reinspect -fireblock between studs at patio fireplace lid, fireplace covered at reinspect -secure CSST gas lines through covered patio attic space per manufacture installation requirements, fireplace covered at reinspect
Gas Service Inspection - Residential Passed 2/24/2022 2/24/2022 02/24/2022
Misc
Resolved
02/24/2022
-GAS LINE BOND REQUIRED PRESSURE OK
All Rough Inspection - Residential Passed 3/1/2022 3/1/2022 03/01/2022
Misc
Resolved
03/01/2022
-overnotched studs at anchor bolts dbl door garage wall -complete HVAC duct removed during fireblock at garage furred down -header and add joist hangers per code to floor joists cut for HVAC at chase kitchen, floor joists currently supported by non load bearing walls (the header needs to be connected to adjacent floor joists to distribute load of joists, the header is still resting on a non load bearing wall and all joists need joists hangers at 4’) -fireblock floor penetration for HVAC at chase kitchen -solid block between joists at all cantilevers, see dining room cantilever -seal all bottom plate penetrations at kitchen -fireblock chases at great room windows -fireblock vertical to horizontal at chase to furred down great room windows -seal gas line penetration at patio fireplace lid, fireplace covered at reinspect -fireblock between studs at patio fireplace lid, fireplace covered at reinspect -secure CSST gas lines through covered patio attic space per manufacture installation requirements, fireplace covered at reinspect
Driveway Inspection Partial 4/6/2022 4/6/2022 04/06/2022
Misc
Informational
04/06/2022
Driveway was framed up with aggregate in and compacted. 4/6/22 ES
Sidewalk Inspection Partial 4/6/2022 4/6/2022 04/06/2022
Misc
Informational
04/06/2022
Sidewalk was framed up with aggregate in and compacted. 4/6/22 ES
Sewer Service Inspection - R Passed 4/12/2022 (3:00) 4/12/2022 04/12/2022
Water Service Inspection - R Partial 04/12/2022
Water Service Inspection - R Passed 4/14/2022 (9:45) 4/14/2022 04/14/2022
Erosion Control Inspection Residential Failed 4/14/2022 4/14/2022 04/14/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/14/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Sidewalk Inspection Partial 4/15/2022 4/15/2022 04/15/2022
Misc
Informational
04/06/2022
Sidewalk was framed up with aggregate in and compacted. 4/6/22 ES
Misc
Informational
04/15/2022
Sidewalk not completely poured and what was had dirt covering it. 4/15/22 ES
Driveway Inspection Partial 4/15/2022 4/15/2022 04/15/2022
Misc
Informational
04/06/2022
Driveway was framed up with aggregate in and compacted. 4/6/22 ES
Misc
Informational
04/15/2022
Driveway meets LS and Ada specs. 4/15/22 ES
Sidewalk Inspection Partial 4/22/2022 4/22/2022 04/22/2022
Misc
Informational
04/15/2022
Sidewalk was framed up with aggregate in and compacted. 4/6/22 ES
Misc
Informational
04/15/2022
Sidewalk not completely poured and what was had dirt covering it. 4/15/22 ES
Misc
Corrective Action Required
04/22/2022
Sidewalk still covered with dirt and unable to be inspected for final. 4/22/22 ES
Sidewalk Inspection Partial 5/9/2022 5/9/2022 05/10/2022
Misc
Informational
04/22/2022
Sidewalk was framed up with aggregate in and compacted. 4/6/22 ES
Misc
Informational
04/22/2022
Sidewalk not completely poured and what was had dirt covering it. 4/15/22 ES
Misc
Corrective Action Required
04/22/2022
Sidewalk still covered with dirt and unable to be inspected for final. 4/22/22 ES
Misc
Informational
05/10/2022
Remainder of sidewalk was formed up with aggregate in and compacted. 5/9/22 ES
Occupancy Inspection - Codes Residential Not Ready 6/3/2022 6/3/2022 06/03/2022
Misc
Corrective Action Required
06/03/2022
INSPECTION DENIED NOT READY FOR OCCUPANCY INSPECTION
Occupancy Inspection - Codes Residential Failed 6/7/2022 6/7/2022 06/07/2022
Misc
Corrective Action Required
06/03/2022
-resolve outstanding inspection fees -final driveway and sidewalk inspection required -final grade and sod -splash blocks -provide guardrail at front porch -install attic access covers -complete carpet install 2nd floor stairs -provide access per code to jacuzzi tub motor at master bath -install hinges and security screws back door
Erosion Control Inspection Residential Partial 06/07/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/07/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Driveway Inspection Passed 6/8/2022 6/8/2022 06/08/2022
Misc
Informational
04/15/2022
Driveway was framed up with aggregate in and compacted. 4/6/22 ES
Misc
Informational
04/15/2022
Driveway meets LS and Ada specs. 4/15/22 ES
Sidewalk Inspection Passed 6/8/2022 6/8/2022 06/08/2022
Misc
Informational
05/10/2022
Sidewalk was framed up with aggregate in and compacted. 4/6/22 ES
Misc
Informational
05/10/2022
Sidewalk not completely poured and what was had dirt covering it. 4/15/22 ES
Misc
Corrective Action Required
05/10/2022
Sidewalk still covered with dirt and unable to be inspected for final. 4/22/22 ES
Misc
Informational
05/10/2022
Remainder of sidewalk was formed up with aggregate in and compacted. 5/9/22 ES
Occupancy Inspection - Codes Residential Temporary C of O 6/10/2022 6/10/2022 06/10/2022
Misc
Corrective Action Required
06/07/2022
-final grade and sod -splash blocks -provide guardrail at front porch, (measured out on 36" horizontal plane) **OK FOR TCO, TCO EXPIRES 6/30/22**
Erosion Control Inspection Residential Passed 06/23/2022
Plot Plan Inspection Passed 6/23/2022 6/23/2022 06/23/2022
Occupancy Inspection - Codes Residential Full C of O 6/23/2022 6/23/2022 06/23/2022
Misc
Resolved
06/23/2022
Documents & Images
Date Uploaded File Type Document Name
04/15/2021 Application Form Permit Application and License Tax Form
04/15/2021 Approved Plans Approved Truss Layout
04/15/2021 Approved Plans Approved Truss Package
04/16/2021 Letter Codes Residential Plan Review
04/22/2021 Plot Plan Approved Plot Plan
05/14/2021 Approved Plans Approved Drawings
05/14/2021 Permit DS Building Permit
05/14/2021 Receipt Receipt for transaction:2021-003016
08/05/2021 87 Reserve at Stoney Creek FTNG
08/06/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
01/27/2022 Letter INSPECTION SUMMARY
01/27/2022 Letter INSPECTION SUMMARY
02/03/2022 Letter INSPECTION SUMMARY
02/03/2022 Letter INSPECTION SUMMARY
02/14/2022 87 reserve at stoney creek letter
02/15/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
02/24/2022 Letter INSPECTION SUMMARY
02/24/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
06/03/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/09/2022 Receipt Receipt for transaction:2022-004480
06/10/2022 Letter Codes Temporary Certificate of Occupancy
06/23/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter Field Certificate of Occupancy
06/23/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home