Permit Application Status

PRRES20211621


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211621
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
04/07/2021
04/09/2021
10/04/2021
10/21/2022
Locations
Contacts
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
BSHELTON@IQHOMEBUILDERS.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/12/2021 04/08/2021
Kim Brennan
Deck location
Corrective Action Required
04/08/2021

Deck location, with dimensions to property lines must be provided on the plot plan. Please show this as a covered deck
Residential Plan Review Approved 04/12/2021 04/08/2021
Kim Brennan
Residential Plan Review Approved 04/09/2021 04/08/2021
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
04/07/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) Not shown on the main level
Plot Plan Review Rejected 04/09/2021 04/07/2021
Kim Brennan
Deck location
Corrective Action Required
04/07/2021

Deck location, with dimensions to property lines must be provided on the plot plan. Please show this as a covered deck
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,190.87 $1,190.87 Paid 04/09/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/09/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/09/2021
8331507-Sewer Connection Fee $570.00 $570.00 Paid 04/09/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/09/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/09/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/11/2022
9110078-Valuation Fee New Single Family $43.01 $43.01 Paid 01/11/2022
$1,234.88
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 09/28/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/21/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/3/2021 (11:30) 5/3/2021 05/03/2021
Underslab Plumbing Inspection - Residential Failed 5/14/2021 5/14/2021 05/14/2021
Misc
Corrective Action Required
05/14/2021
-POST ADDRESS -INTERIOR DRAIN TILE REQUIRED
Underslab Plumbing Inspection - Residential Passed 5/19/2021 5/19/2021 05/18/2021
Misc
Resolved
05/18/2021
-POST ADDRESS -INTERIOR DRAIN TILE REQUIRED
Sewer Service Inspection - R Passed 5/20/2021 (1:45) 5/20/2021 05/20/2021
Water Service Inspection - R Partial 5/24/2021 05/24/2021
Misc
Informational
05/24/2021
Partial water approval from structure to metallic connection customer side of meter
Water Service Inspection - R Passed 5/25/2021 (11:00) 5/25/2021 05/25/2021
Misc
Informational
05/24/2021
Partial water approval from structure to metallic connection customer side of meter
All Rough Inspection - Residential Failed 8/12/2021 8/12/2021 08/12/2021
Misc
Corrective Action Required
08/12/2021
8-12-21 Portal frame exterior ok to cover
Erosion Control Inspection Residential Failed 9/30/2021 9/30/2021 09/30/2021
Misc
Corrective Action Required
09/30/2021
9-30-21 -Maintain silt fence, gravel filter, overgrown vegitation, loose trash and debris
Piers/Caissons Inspection - Residential Passed 9/30/2021 (9:45) 9/30/2021 09/30/2021
Misc
Informational
09/30/2021
-(2) 24x36 piers
All Rough Inspection - Residential Failed 10/14/2021 10/14/2021 10/14/2021
Misc
Corrective Action Required
08/12/2021
8-12-21 Portal frame exterior ok to cover
Misc
Corrective Action Required
10/14/2021
-Nail garage PFH wall sheathing to sill plate w/8d@3” oc -Fb all floor penetrations throughout ; fb duct chase at half bathroom from joist space -Protect plumbing at half bathroom bottom wall plate -Toe nail all joists to wall top plates -Support front porch roof ridge -Provide 5 stud support for beam at stair wall -Provide wall receptacle spacing per code at 1st fl stair wall -Fb excessive gap at top of wall of bedroom 2 closet -Support ceiling framing above master bedroom **DO NOT INSULATE
Electrical Service Inspection Failed 10/14/2021 10/14/2021 10/14/2021
Misc
Corrective Action Required
10/14/2021
-Connect the grounding electrode conductor to the middle grounded bus bar or install jumper (#4 cu or #2 al) from the EGC bus bar to the grounded bus bar. -Secure all wirings at panel connectors.
Gas Service Inspection - Residential Passed 10/14/2021 10/14/2021 10/14/2021
All Rough Inspection - Residential Not Ready 10/19/2021 10/19/2021 10/19/2021
Misc
Corrective Action Required
10/14/2021
8-12-21 Portal frame exterior ok to cover
Misc
Corrective Action Required
10/14/2021
-Nail garage PFH wall sheathing to sill plate w/8d@3” oc -Fb all floor penetrations throughout ; fb duct chase at half bathroom from joist space -Protect plumbing at half bathroom bottom wall plate -Toe nail all joists to wall top plates -Support front porch roof ridge -Provide 5 stud support for beam at stair wall -Provide wall receptacle spacing per code at 1st fl stair wall -Fb excessive gap at top of wall of bedroom 2 closet -Support ceiling framing above master bedroom **DO NOT INSULATE
Electrical Service Inspection Passed 10/19/2021 10/19/2021 10/19/2021
Misc
Resolved
10/19/2021
All Rough Inspection - Residential Failed 10/22/2021 10/22/2021 10/22/2021
Misc
Corrective Action Required
10/19/2021
8-12-21 Portal frame exterior ok to cover
Misc
Corrective Action Required
10/19/2021
-Fb all floor penetrations throughout ; fb duct chase at half bathroom from joist space -Protect plumbing at half bathroom bottom wall plate -Toe nail all joists to wall top plates -Provide wall receptacle spacing per code at 1st fl stair wall -Fb excessive gap at top of wall of bedroom 2 closet **DO NOT INSULATE
All Rough Inspection - Residential Passed 11/2/2021 11/2/2021 11/02/2021
Misc
Corrective Action Required
10/22/2021
8-12-21 Portal frame exterior ok to cover
Misc
Resolved
11/02/2021
Driveway Inspection Partial 12/8/2021 12/8/2021 12/08/2021
Misc
Informational
12/08/2021
On Wednesday 12/8/2021 I performed a driveway inspection and pass the sub-grade to pour concrete
All Rough Inspection - Residential Passed 1/12/2022 1/12/2022 01/12/2022
Erosion Control Inspection Residential Failed 1/27/2022 01/27/2022
Misc
Resolved
01/27/2022
9-30-21 -Maintain silt fence, gravel filter, overgrown vegitation, loose trash and debris
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/27/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 1/27/2022 1/27/2022 01/27/2022
Misc
Corrective Action Required
01/27/2022
NO FURTHER INSPECTION TO BE PERFORMED UNTIL EROSION CONTROL IS IN PLACE AND IN COMPLIANCE -final grade and sod -check water meter at time of final grade and sod. -Handrail required at garage stairs -can not check outlets in garage -secondary locking device on sliding back door -handrail to basement required -hardware on basement sliding back door -electrical in unfinished area not landed next to water heater -lock out for hot water heater breaker -seal top of meter can, lights, and all other exterior penetrations -back patio lighting must be of the sealed type -(2) 1/2” through bolts required at deck post to beam connections
Erosion Control Inspection Residential Partial 2/2/2022 02/02/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/02/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Informational
02/02/2022
erosion control back in compliance Mitchell Schwarz 02/02/2022 9:13 AM
Occupancy Inspection - Codes Residential Failed 2/2/2022 2/2/2022 02/02/2022
Misc
Corrective Action Required
01/27/2022
-sod -check water meter and siding from grade at time of final grade and sod. -hardware on basement sliding back door -electrical in unfinished area not landed next to water heater -lock out for hot water heater breaker -seal top of meter can, lights, and all other exterior penetrations -back patio lighting must be of the sealed type -(2) 1/2” through bolts required at deck post to beam connections
Occupancy Inspection - Codes Residential Temporary C of O 2/4/2022 2/4/2022 02/04/2022
Misc
Corrective Action Required
02/02/2022
TCO UNTIL 4/4/22 -sod -check water meter and siding from grade at time of final grade and sod. -seal top of meter can, lights, and all other exterior penetrations -(2) 1/2” through bolts required at deck post to beam connections -basment still needing inspection
Plot Plan Inspection Passed 3/16/2022 03/16/2022
Occupancy Inspection - Codes Residential Temporary C of O 3/16/2022 3/16/2022 03/16/2022
Misc
Corrective Action Required
02/04/2022
TCO UNTIL 4/4/22 -sod -check water meter and siding from grade at time of final grade and sod. -seal top of meter can, lights, and all other exterior penetrations -(2) 1/2” through bolts required at deck post to beam connections -Address pending driveway inspection all interior has been checked and is good
Occupancy Inspection - Codes Residential Failed 8/15/2022 8/15/2022 08/15/2022
Misc
Corrective Action Required
03/16/2022
-submit TCO extension request -(2) 1/2” through bolts required at deck post to beam connections -Address pending driveway inspection -address siding from ground
Driveway Inspection Passed 9/12/2022 09/12/2022
Misc
Informational
12/08/2021
On Wednesday 12/8/2021 I performed a driveway inspection and pass the sub-grade to pour concrete 9-12-22 RH. Driveway meets LS specification.
Erosion Control Inspection Residential Passed 9/12/2022 09/12/2022
Misc
Resolved
09/12/2022
erosion control back in compliance Mitchell Schwarz 02/02/2022 9:13 AM
Occupancy Inspection - Codes Residential Not Ready 9/12/2022 9/12/2022 09/12/2022
Misc
Corrective Action Required
08/15/2022
TCO EXPIRED SUBMIT TCO EXTENSION REQUEST FORM -pay all fees -(2) 1/2” through bolts required at deck post to beam connections -address siding from ground -provide access to back yard for viewing
Occupancy Inspection - Codes Residential Ready for Temp CO 10/21/2022 10/21/2022 10/21/2022
Misc
Corrective Action Required
09/12/2022
-pay all fees -(2) 1/2” through bolts required at deck post to beam connections -address siding from ground -provide access to back yard for viewing
Occupancy Inspection - Codes Residential Full C of O 10/21/2022 10/21/2022
Misc
Resolved
10/21/2022
-pay all fees -(2) 1/2” through bolts required at deck post to beam connections -address siding from ground -provide access to back yard for viewing
Documents & Images
Date Uploaded File Type Document Name
04/07/2021 Application Form Permit Application and License Tax Form
04/07/2021 Letter Codes Residential Plan Review
04/08/2021 Approved Plans Approved Drawings
04/08/2021 Plot Plan Approved Plot Plan
04/09/2021 Receipt Receipt for transaction:2021-001871
04/09/2021 Letter DS Building Permit
05/03/2021 Letter INSPECTION SUMMARY
05/14/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/20/2021 Letter INSPECTION SUMMARY
05/24/2021 Letter INSPECTION SUMMARY
05/25/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/19/2021 Letter INSPECTION SUMMARY
10/19/2021 Letter INSPECTION SUMMARY
10/22/2021 Letter INSPECTION SUMMARY
11/02/2021 Letter INSPECTION SUMMARY
12/08/2021 Letter INSPECTION SUMMARY
12/29/2021 Approved Plans Approved Basement Plan
01/11/2022 Receipt Receipt for transaction:2022-000183
01/12/2022 Letter INSPECTION SUMMARY
01/27/2022 Letter INSPECTION SUMMARY
01/27/2022 Letter INSPECTION SUMMARY
02/02/2022 Letter INSPECTION SUMMARY
02/02/2022 Letter INSPECTION SUMMARY
02/04/2022 Letter Codes Temporary Certificate of Occupancy
03/16/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter Codes Temporary Certificate of Occupancy
08/15/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter Codes 10 Day Letter
09/28/2022 Receipt Receipt for transaction:2022-007874
10/21/2022 2333 SW Old Port Rd - Extension Form
10/21/2022 Certificate/License Codes Temporary Certificate of Occupancy
10/21/2022 Receipt Receipt for transaction:2022-008428
10/21/2022 Letter Codes Final Certificate of Occupancy
10/21/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home