Permit Application Status

PRRES20211516


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211516
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
04/01/2021
04/05/2021
06/16/2022
Locations
Contacts
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
JENNIFER@IQHOMEBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/06/2021 04/02/2021
Brandon Kalwei
Residential Plan Review Approved 04/06/2021 04/02/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,198.27 $1,198.27 Paid 04/05/2021
8331507-Sewer Connection Fee $570.00 $570.00 Paid 04/05/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/05/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/05/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/05/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/05/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 12/08/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 4/19/2021 (3:00) 4/19/2021 04/19/2021
Misc
Corrective Action Required
04/19/2021
Remove water
Erosion Control Inspection Residential Failed 4/19/2021 04/19/2021
Misc
Corrective Action Required
04/19/2021
-Establish erosion control methods within 48 hours -immediate street cleanup required -no further inspections until issues are resolved
Miscellaneous Inspection Failed 4/19/2021 04/19/2021
Misc
Corrective Action Required
04/19/2021
Post site address
Footing Inspection - Residential Passed 4/21/2021 (1:30) 4/21/2021 04/21/2021
Misc
Resolved
04/21/2021
Remove water
Underslab Plumbing Inspection - Residential Passed 5/19/2021 5/19/2021 05/18/2021
Sewer Service Inspection - R Passed 5/26/2021 05/26/2021
Water Service Inspection - R Passed 5/28/2021 05/28/2021
All Rough Inspection - Residential Partial 7/16/2021 7/16/2021 07/16/2021
Misc
Corrective Action Required
07/16/2021
**7/16/21 - GARAGE PORTAL EXTERIOR OK TO COVER**
Electrical Service Inspection Failed 7/29/2021 7/29/2021 07/29/2021
Misc
Corrective Action Required
07/29/2021
Identify Ufer ground at both ends
Gas Service Inspection - Residential Failed 7/29/2021 7/29/2021 07/29/2021
Misc
Corrective Action Required
07/29/2021
-No gas installed-not ready
All Rough Inspection - Residential Not Ready 7/29/2021 7/29/2021 07/29/2021
Misc
Corrective Action Required
07/16/2021
**7/16/21 - GARAGE PORTAL EXTERIOR OK TO COVER**
Miscellaneous Correction
Corrective Action Required
07/29/2021
7-29-21 -NOT READY -RE ESTABLISH EROSION CONTROL AT PERIMETER -COMPLETE PLUMBING -SEAL ALL PENETRATIONS -INSTALL GAS
Erosion Control Inspection Residential Failed 8/3/2021 08/03/2021
Misc
Resolved
08/03/2021
-Establish erosion control methods within 48 hours -immediate street cleanup required -no further inspections until issues are resolved
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/03/2021
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -ESTABLISH EROSION CONTROL AT PERIMETER OF LOT -POST ADDRESS -NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL IN COMPLIANCE
Piers/Caissons Inspection - Residential Passed 8/3/2021 (10:30) 8/3/2021 08/03/2021
All Rough Inspection - Residential Failed 8/17/2021 8/17/2021 08/17/2021
Misc
Informational
08/17/2021
**7/16/21 - GARAGE PORTAL EXTERIOR OK TO COVER**
Miscellaneous Correction
Corrective Action Required
07/29/2021
-Interior Load bearing walls with top plates bored greater than 50% require structural straps on both sides of wall-straps to extend 6” past opening each direction -Provide (5) studs under LVL at stairs/great room per plans -Strap dwv 2” and smaller at midpoint second level -rafter/collar ties upstairs west bedroom -Address joist with holes bored closer than 2” in basement,garage -Anchor steel columns basement -Install missing egress window -Fireblock opening between garage stairs and basement -Pan off return air above beam basement -Gas line bond required
Electrical Service Inspection Passed 8/18/2021 8/18/2021 08/18/2021
Misc
Resolved
08/18/2021
Identify Ufer ground at both ends
Gas Service Inspection - Residential Passed 8/30/2021 8/30/2021 08/30/2021
Misc
Resolved
08/30/2021
All Rough Inspection - Residential Failed 8/30/2021 8/30/2021 08/30/2021
Misc
Informational
08/17/2021
**7/16/21 - GARAGE PORTAL EXTERIOR OK TO COVER**
Miscellaneous Correction
Corrective Action Required
08/17/2021
-Interior Load bearing walls with top plates bored greater than 50% require structural straps on both sides of wall-straps to extend 6” past opening each direction -Address joist with holes bored closer than 2” in basement furnace intake/exhaust lines,garage pex lines -Anchor steel columns basement
All Rough Inspection - Residential Passed 9/2/2021 9/2/2021 09/02/2021
Misc
Resolved
09/02/2021
**7/16/21 - GARAGE PORTAL EXTERIOR OK TO COVER**
Miscellaneous Correction
Resolved
09/02/2021
-Interior Load bearing walls with top plates bored greater than 50% require structural straps on both sides of wall-straps to extend 6” past opening each direction -Address joist with holes bored closer than 2” in basement furnace intake/exhaust lines,garage pex lines -Anchor steel columns basement
Driveway Inspection Passed 11/10/2021 11/10/2021 11/10/2021
Misc
Informational
11/10/2021
On 11/10/2021 I performed a driveway inspection and pass the subgrade to pour concrete
Occupancy Inspection - Codes Residential Failed 12/7/2021 12/7/2021 12/07/2021
Misc
Corrective Action Required
12/07/2021
-Pay fees -Final grading and sod -Splash blocks -sidewalk and inspection -spark rings needed at kitchen counter - install tub in master - No smoke alarms working - No set screw in back flow preventer at water main - Water heater not operational - No ladder for Egress window - basement stairs handrail not in compliance, code R311.7.8.4 stops short of bottom riser - basement stairs top and bottom riser over 7 3/4”
Sidewalk Inspection Partial 12/8/2021 12/8/2021 12/08/2021
Misc
Informational
12/08/2021
On Wednesday 12.08.2021 I performed a sidewalk inspection and pass the sub-grade to pour concrete.
Occupancy Inspection - Codes Residential Temporary C of O 12/10/2021 12/10/2021 12/10/2021
Misc
Corrective Action Required
12/07/2021
-sidewalk and inspection
Erosion Control Inspection Residential Passed 12/10/2021 12/10/2021
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/03/2021
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -ESTABLISH EROSION CONTROL AT PERIMETER OF LOT -POST ADDRESS -NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL IN COMPLIANCE
Plot Plan Inspection Passed 12/10/2021 12/10/2021
Occupancy Inspection - Codes Residential Failed 1/11/2022 01/11/2022
Misc
Corrective Action Required
12/10/2021
-sidewalk and inspection still needs to be performed call development service to schedule TCO has expired
Sidewalk Inspection Passed 6/16/2022 06/16/2022
Misc
Informational
12/08/2021
On Wednesday 12.08.2021 I performed a sidewalk inspection and pass the sub-grade to pour concrete. On 6.16.2022 the sidewalk appears to be in compliance with City & ADA standards
Occupancy Inspection - Codes Residential Full C of O 6/16/2022 6/16/2022 06/16/2022
Misc
Resolved
06/16/2022
Documents & Images
Date Uploaded File Type Document Name
04/01/2021 Application Form APPLICATION
04/01/2021 LOT 722 FINAL
04/01/2021 EGC722 Spec - Sealed Plans (March 31, 2021)
04/02/2021 Approved Plans APPROVED PLANS
04/02/2021 Plot Plan APPROVED PLOT PLAN
04/05/2021 Receipt Receipt for transaction:2021-001745
04/05/2021 Letter DS Building Permit
04/19/2021 Letter INSPECTION SUMMARY
04/19/2021 Letter INSPECTION SUMMARY
04/19/2021 Letter INSPECTION SUMMARY
04/21/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/26/2021 Letter INSPECTION SUMMARY
05/28/2021 Letter INSPECTION SUMMARY
07/16/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
08/17/2021 Letter INSPECTION SUMMARY
08/18/2021 Letter INSPECTION SUMMARY
08/18/2021 Letter INSPECTION SUMMARY
08/30/2021 Letter INSPECTION SUMMARY
08/30/2021 Letter INSPECTION SUMMARY
08/30/2021 2350 SW Old Port Road - Structural Letter (August 30, 2021)
09/02/2021 Letter INSPECTION SUMMARY
11/10/2021 Letter INSPECTION SUMMARY
12/07/2021 Letter INSPECTION SUMMARY
12/08/2021 Receipt Receipt for transaction:2021-009186
12/08/2021 Letter INSPECTION SUMMARY
12/10/2021 Letter Codes Temporary Certificate of Occupancy
12/20/2021 Letter INSPECTION SUMMARY
12/20/2021 Letter INSPECTION SUMMARY
01/11/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter Codes 140 Day Letter
06/07/2022 Letter Codes 140 Day Letter
06/16/2022 Letter Codes Final Certificate of Occupancy
06/16/2022 Letter INSPECTION SUMMARY
06/16/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: