Permit Application Status

PRRES20211432


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211432
Building Permit - Residential
Certificate of Occupancy
SUMMIT VIEW FARMS DEVELOPMENT GROUP LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
03/30/2021
04/29/2021
10/19/2021
01/27/2023
Locations
Contacts
SUMMIT VIEW FARMS DEVELOPMENT GROUP LLC, Address:13450 E STATE ROUTE 150  
DOUGLAS LANDSCAPE & DESIGN LLC, Address:1713 NE WHITESTONE DR, Phone:(816) 927-5906  
dldesign69@gmail.com  
HALTEMAN HEATING & AIR CONDITIONING LLC, Address:9600 S CORN RD, Phone:(816) 215-9761  
J AND W ELECTRIC LLC, Address:4468 COUNTRY SQUIRE LANE, Phone:(816) 824-5581  
ACCU-PLUMBING INC, Address:PO BOX 683, Phone:(816) 229-4776  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/26/2021 04/22/2021
Brandon Kalwei
As-graded plot plan
Corrective Action Required
04/22/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 04/26/2021 04/22/2021
Brandon Kalwei
01 One (1) complete permit application
Corrective Action Required
04/22/2021

One (1) complete permit application. Application does not show unfinished basement sq. ft. and suspended slab. plans show both unfinished basement and suspended slab. need to correct application
Miscellaneous Correction
Corrective Action Required
04/22/2021

need to confirm plumbing contractor's business name
Plot Plan Review Rejected 04/01/2021 03/30/2021
Brandon Kalwei
Rear yard dimension
Corrective Action Required
03/30/2021

The rear yard demision(s) must be provided on the plot plan.
Deck location
Corrective Action Required
03/30/2021

Deck location, with dimensions to property lines must be provided on the plot plan. in R-1 zoning, the primary structure cannot be within 30' of the property line. The covered deck is currently at 23.2'
Sidewalks
Corrective Action Required
03/30/2021

Sidewalks with dimensions must be provided on the plot plan.
Drainage swales/berms
Corrective Action Required
03/30/2021

Drainage swales/berms: provide cross-section elevations as required to conform to the accepted "As graded" Master Drainge Plan (MDP), include cross-section detail from MDP. no swale shown on plot plan, swale shown on MDP. needs to be on the plot plan.
Drainage swales
Corrective Action Required
03/30/2021

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provide no swale shown on plot plan, swale shown on MDP. needs to be on the plot plan.
Basement opening elevations
Corrective Action Required
03/30/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
As-graded plot plan
Corrective Action Required
03/30/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Rejected 04/01/2021 03/30/2021
Brandon Kalwei
01 One (1) complete permit application
Corrective Action Required
03/30/2021

One (1) complete permit application. Application does not show unfinished basement sq. ft. and suspended slab. plans show both unfinished basement and suspended slab. need to correct application
19 Footings, column pads, piers and grade beams - dimensions
Corrective Action Required
03/30/2021

Footings, column pads, piers and grade beams - dimensions. (IRC Section R403) do not see details for column pads
20 Footings, column pads, piers and grade beams - reinforcement
Corrective Action Required
03/30/2021

Footings, column pads, piers and grade beams - reinforcement size and spacing. do not see details for column pads
Miscellaneous Correction
Corrective Action Required
03/30/2021

need to confirm plumbing contractor's business name
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,079.62 $1,079.62 Paid 04/29/2021
8331507-Sewer Connection Fee $510.00 $510.00 Paid 04/29/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/29/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/29/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/29/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/29/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/26/2023
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/26/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/26/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/26/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/26/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/26/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/26/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/26/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 7/28/2021 7/28/2021 07/28/2021
Misc
Corrective Action Required
07/28/2021
SITE BEING EXCAVATED WITH NO EROSION CONTROL PRESENT. INSTALL EROSION CONTROL AT LOT PERMITER IMMEDIATLEY
Footing Inspection - Residential Passed 8/3/2021 (8:00) 8/3/2021 08/03/2021
Underslab Plumbing Inspection - Residential Failed 9/3/2021 9/3/2021 09/03/2021
Misc
Corrective Action Required
09/03/2021
-POST ADDRESS -INTERIOR DRAIN TILE REQUIRED -UNABLE TO INSPECT COMPLETE DWV DUE TO HEAVY RAINS AND FLOAT, RESCHEDULE WHEN CONDITIONS ALLOW FOR COMPLETE INSPECTION
Underslab Plumbing Inspection - Residential Passed 9/24/2021 9/24/2021 09/24/2021
Misc
Resolved
09/24/2021
Piers/Caissons Inspection - Residential Passed 9/28/2021 (2:00) 9/28/2021 09/28/2021
Misc
Informational
09/28/2021
(3) 24x36 piers
Gas Service Inspection - Residential Passed 11/30/2021 11/30/2021 11/30/2021
All Rough Inspection - Residential Not Ready 12/8/2021 12/8/2021 12/08/2021
Misc
Corrective Action Required
12/08/2021
INSPECTION DENIED -NO CITY STAMPED PLANS ON SUTE AT TIME OF INSPECTION
All Rough Inspection - Residential Failed 12/9/2021 12/9/2021 12/09/2021
Misc
Corrective Action Required
12/08/2021
-PFH Panel splices within middle 24” of portal leg -Nail exterior sheathing per design at PFH, unable to confirm 3” oc grid nailing pattern at sheathing to header with cover -PFH requires dbl bottom plate with 5/8” anchor bolt with 2” x 2” x 3/16 “ washer -seal unused top plate penetration garage -bocca protection plates must protect at plate and 2” above or below at top and bottom plates- see DWV garage wall -span rafters properly, glued end joints throughout not correct -fireblock deadspace at stair wall master bed closet -minimum (4) 10D nails each side of structural straps - see master bath vanity exterior wall top plate -Nail intersecting wall corners 12” oc -Tempered glass required at great room windows at fireplace and basement den, less than 18” from floor -Install all exterior doors -address exterior walls not tied together at top plate, kitchen breakfast, master bedroom, East garage wall -King stud required at deck door header -Install all windows -Stud shoe at DWV kitchen exterior wall -seal top plate penetrations great room fireplace -provide lateral restraint ceiling joists at foyer -T bracing at roof purlins -minimum (2) stud pack at bearing end points per plans -complete all furred downs throughout finished basement -solid block between joists above beams at basement, lateral restraint -address overnotched stud exterior wall basement den south wall anchor bolt -fireblock between studs at wall bump outs throughout basement den, bedroom, closet, open to joist space at top plates -Fireblock between top plates at finished basement, loose insulation does not hold -Fireblock deadspace at basement shower -add joist hangers to all joists 4’ or more at basement den and closet -solid block between joists at cantilevers -Nail all joist hangers at basement -shield pex against recessed can light at basement bath -Nail all exterior sheathing per plans, 6” edge 12” field **DO NOT INSULATE**
Electrical Service Inspection Passed 12/9/2021 12/9/2021 12/09/2021
All Rough Inspection - Residential Not Ready 12/13/2021 12/13/2021 12/13/2021
Misc
Corrective Action Required
12/09/2021
12/13/21 - TRADES WORKING ON CORRECTIONS AT TIME OF INSPECTION, COMPLETE ALL CORRECTIONS AND RESCHEDULE INSPECTION -PFH Panel splices within middle 24” of portal leg -Nail exterior sheathing per design at PFH, unable to confirm 3” oc grid nailing pattern at sheathing to header with cover -PFH requires dbl bottom plate with 5/8” anchor bolt with 2” x 2” x 3/16 “ washer -seal unused top plate penetration garage -bocca protection plates must protect at plate and 2” above or below at top and bottom plates- see DWV garage wall -span rafters properly, glued end joints throughout not correct - SUBMIT ENGINEER LETTER -fireblock deadspace at stair wall master bed closet -minimum (4) 10D nails each side of structural straps - see master bath vanity exterior wall top plate -Nail intersecting wall corners 12” oc -Tempered glass required at great room windows at fireplace and basement den, less than 18” from floor -Install all exterior doors -address exterior walls not tied together at top plate, kitchen breakfast, master bedroom, East garage wall -King stud required at deck door header -Install all windows -Stud shoe at DWV kitchen exterior wall -seal top plate penetrations great room fireplace -provide lateral restraint ceiling joists at foyer -T bracing at roof purlins -minimum (2) stud pack at bearing end points per plans -complete all furred downs throughout finished basement -solid block between joists above beams at basement, lateral restraint -address overnotched stud exterior wall basement den south wall anchor bolt -fireblock between studs at wall bump outs throughout basement den, bedroom, closet, open to joist space at top plates -Fireblock between top plates at finished basement, loose insulation does not hold -Fireblock deadspace at basement shower -add joist hangers to all joists 4’ or more at basement den and closet -solid block between joists at cantilevers -Nail all joist hangers at basement -shield pex against recessed can light at basement bath -Nail all exterior sheathing per plans, 6” edge 12” field **DO NOT INSULATE**
All Rough Inspection - Residential Failed 12/15/2021 12/15/2021 12/15/2021
Misc
Corrective Action Required
12/13/2021
-span rafters properly, glued end joints throughout not correct - (SUBMITTED DOCUMENTATION UNDER REVIEW) -fireblock deadspace at stair wall master bed closet - area open to attic right of deadspace closet -Tempered glass required at great room windows at fireplace and basement den, less than 18” from floor -Install all exterior doors -address exterior walls not tied together at top plate, kitchen breakfast, master bedroom -fireblock between studs at wall bump outs throughout basement den, bedroom, closet, open to joist space at top plate **OK TO INSULATE**
All Rough Inspection - Residential Failed 12/16/2021 12/16/2021 12/16/2021
Misc
Corrective Action Required
12/15/2021
-span rafters properly, glued end joints throughout not correct - (SUBMITTED DOCUMENTATION UNDER REVIEW) -Tempered glass required at great room windows at fireplace and basement den, less than 18” from floor -Install all exterior doors and windows **OK TO INSULATE**
Sewer Service Inspection - R Passed 1/5/2022 (8:00) 1/5/2022 01/05/2022
Water Service Inspection - R Passed 1/11/2022 (8:45) 1/11/2022 01/11/2022
Suspended Slab Inspection Passed 3/1/2022 (8:15) 3/1/2022 03/01/2022
Driveway Inspection Partial 2/28/2022 2/28/2022 03/01/2022
Misc
Informational
03/01/2022
On 2.28.2022 Monday I performed a driveway inspection and pass the subgrade to pour concrete
All Rough Inspection - Residential Passed 3/10/2022 03/10/2022
Misc
Resolved
03/10/2022
-span rafters properly, glued end joints throughout not correct - (SUBMITTED DOCUMENTATION UNDER REVIEW) -Tempered glass required at great room windows at fireplace and basement den, less than 18” from floor -Install all exterior doors and windows **OK TO INSULATE**
Occupancy Inspection - Codes Residential Temporary C of O 3/10/2022 3/10/2022 03/10/2022
Misc
Corrective Action Required
03/10/2022
TCO until - 4/11/22 -All exterior items still need to be checked -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -pay all fees before final C/o -complete driveway and side walk inspection
Erosion Control Inspection Residential Failed 3/29/2022 03/29/2022
Misc
Resolved
03/29/2022
SITE BEING EXCAVATED WITH NO EROSION CONTROL PRESENT. INSTALL EROSION CONTROL AT LOT PERMITER IMMEDIATLEY
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/29/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 03/29/2022 3:04 PM
Sidewalk Inspection Passed 9/1/2022 09/01/2022
Misc
Informational
09/01/2022
9-1-22 RH. Sidewalk meets LS and ADA specification.
Driveway Inspection Passed 9/1/2022 09/01/2022
Misc
Informational
03/01/2022
On 2.28.2022 Monday I performed a driveway inspection and pass the subgrade to pour concrete 9-1-22 RH. Driveway meets LS and ADA specification.
Erosion Control Inspection Residential Passed 9/1/2022 09/01/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
09/01/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 03/29/2022 3:04 PM
Plot Plan Inspection Passed 9/1/2022 09/01/2022
Occupancy Inspection - Codes Residential Failed 9/1/2022 9/1/2022 09/01/2022
Misc
Corrective Action Required
03/10/2022
TCO until - 4/11/22 -submit tco extension request -All exterior items still need to be checked -tamper caps at A/c unit -splash blocks and sump pump discharge to extend 36” from foundation -pay all fees before final C/o
Occupancy Inspection - Codes Residential Full C of O 1/27/2023 01/27/2023
Misc
Resolved
01/27/2023
TCO until - 4/11/22 -submit tco extension request -All exterior items still need to be checked -tamper caps at A/c unit -splash blocks and sump pump discharge to extend 36” from foundation -pay all fees before final C/o
Documents & Images
Date Uploaded File Type Document Name
03/30/2021 3105 Plat
03/30/2021 3105 Prints
03/30/2021 Letter Codes Residential Plan Review
03/31/2021 Jason's plumber
03/31/2021 Updated Permit App 3105
03/31/2021 Application Form APPLICATION
04/22/2021 SUMMIT VIEW FARMS LOT 51
04/22/2021 3297
04/22/2021 Approved Plans APPROVED PLANS
04/22/2021 Plot Plan APPROVED PLOT PLAN
04/29/2021 Receipt Receipt for transaction: 2021-002357
04/29/2021 Letter DS Building Permit
04/30/2021 Updated3297
04/30/2021 Approved Plans updated approved plans
07/28/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
09/03/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
12/08/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/13/2021 Letter INSPECTION SUMMARY
12/15/2021 Letter INSPECTION SUMMARY
12/16/2021 Letter INSPECTION SUMMARY
01/05/2022 Letter INSPECTION SUMMARY
01/11/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/10/2022 structural-glued-lumber-tg9
03/10/2022 TN2020-01HRA-FJ
03/10/2022 IMG_20211211_122709385
03/10/2022 Fwd_ 2x6x30 Doug Fir Finger Jointed
03/10/2022 Ultra600 specs
03/10/2022 Re_ I am sharing 'Ultra600 specs' with you
03/10/2022 Letter INSPECTION SUMMARY
03/10/2022 Letter Codes Temporary Certificate of Occupancy
03/29/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
01/19/2023 Letter Codes 10 Day Letter
01/26/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/26/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/26/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/26/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/26/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/26/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/26/2023 Receipt Receipt for transaction:2023-000501
01/27/2023 Letter INSPECTION SUMMARY
01/27/2023 Letter INSPECTION SUMMARY
01/27/2023 Letter Field Certificate of Occupancy
01/27/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home