Permit Application Status

PRRES20211220


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211220
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
03/18/2021
04/02/2021
09/29/2021
08/18/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/06/2021 04/02/2021
Brandon Kalwei
Basement opening elevations
Corrective Action Required
04/02/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
Residential Plan Review Approved 04/06/2021 04/02/2021
Brandon Kalwei
Residential Plan Review Approved 03/22/2021 03/19/2021
Brandon Kalwei
Plot Plan Review Rejected 03/22/2021 03/18/2021
Brandon Kalwei
Basement opening elevations
Corrective Action Required
03/18/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $898.38 $898.38 Paid 04/02/2021
8331507-Sewer Connection Fee $420.00 $420.00 Paid 04/02/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/02/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/02/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/02/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/02/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/15/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 06/15/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 06/15/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 5/21/2021 05/21/2021
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
05/21/2021
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - MAINTAIN SILT FENCE - - CLEAN STREET -
Footing Inspection - Residential Passed 5/21/2021 05/21/2021
Misc
Informational
05/21/2021
3RD PARTY FOOTING BY COLBY SHAW @ EVERSTEAD SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED CENTER OF REAR FOUNDATION WALL GARAGE
Underslab Plumbing Inspection - Residential Failed 6/21/2021 6/21/2021 06/21/2021
Misc
Corrective Action Required
06/21/2021
PROVIDE INTERIOR DRAIN TILE
Underslab Plumbing Inspection - Residential Passed 7/9/2021 7/9/2021 07/09/2021
Misc
Resolved
07/09/2021
Sewer Service Inspection - R Passed 11/23/2021 11/23/2021
Water Service Inspection - R Passed 12/2/2021 (10:30) 12/2/2021 12/02/2021
All Rough Inspection - Residential Not Ready 1/6/2022 1/6/2022 01/06/2022
Miscellaneous Correction
Corrective Action Required
01/06/2022
No truss package Plans missing A3 Wouldn’t pull up online Fire blocking not done , Not ready
Electrical Service Inspection Passed 1/6/2022 1/6/2022 01/06/2022
Gas Service Inspection - Residential Passed 1/6/2022 1/6/2022 01/06/2022
All Rough Inspection - Residential Failed 1/11/2022 1/11/2022 01/11/2022
Miscellaneous Correction
Corrective Action Required
01/11/2022
Provide truss lock screw truss E04 master bed Provide H2.5 / truss lock trusses above fire place Truss lock screws shall run through double top plate bed 2 J01 & D01 Provide min stud pack of (4) 2x4 at girder truss bearing points Nail intersecting wall corners per code Nail exterior wall sheathing per code Seal fire blocking fireplace Seal upward penetrations bottom plate kitchen Seal upward penetrations top plate bath 2 Strap top plate above front door no overlap Fire block dryer vent at furr out laundry Seal bores in stud cavities used as plenum foyer Seal upward penetrations top plate garage Provide 2x2x3/16 plate washers per plan PFH portal framing garage Provide nuts, washers & tighten anchor bolts basement Provide solid security blocking patio door Provide double 2 x 10 joist at deck per plan Provide CS-PF at patio windows per plan Insulate & solid block cantilever above patio windows Address joist cut at B vent near furnace Seal upward penetration top plate above door a bottom of stairs
All Rough Inspection - Residential Failed 1/31/2022 1/31/2022 01/31/2022
Miscellaneous Correction
Corrective Action Required
01/11/2022
Provide H2.5 / truss lock trusses above fire place Strap top plate above front door no overlap Fire block dryer vent at furr out laundry Provide nuts, washers & tighten anchor bolts basement Provide solid security blocking patio door Provide double 2 x 10 joist at deck per plan Seal upward penetration top plate above door a bottom of stairs
All Rough Inspection - Residential Failed 2/2/2022 2/2/2022 02/02/2022
Miscellaneous Correction
Corrective Action Required
01/31/2022
Strap top plate above front door no overlap East side
All Rough Inspection - Residential Passed 2/8/2022 2/8/2022 02/08/2022
Miscellaneous Correction
Resolved
02/08/2022
Driveway Inspection Partial 2/9/2022 2/9/2022 02/09/2022
Misc
Informational
02/09/2022
Driveway was framed up with aggregate in and compacted. 2/9/22 ES
Driveway Inspection Passed 2/18/2022 2/18/2022 02/28/2022
Misc
Informational
02/09/2022
Driveway was framed up with aggregate in and compacted. 2/9/22 ES
Misc
Informational
02/28/2022
Driveway meets LS and Ada specs. 2/28/22 ES
Sidewalk Inspection Partial 3/28/2022 3/28/2022 03/28/2022
Misc
Informational
03/28/2022
Forms were placed and aggregate was present and compacted. They poured the sidewalk up to the property line as requested. RP 3-28-22
Sidewalk Inspection Passed 4/1/2022 4/1/2022 04/01/2022
Misc
Informational
03/28/2022
Forms were placed and aggregate was present and compacted. They poured the sidewalk up to the property line as requested. RP 3-28-22
Misc
Informational
04/01/2022
Finished sidewalk meets LS and ADA specs. RP 4-1-22
Erosion Control Inspection Residential Passed 06/15/2022
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
06/15/2022
Plot Plan Inspection Passed 06/15/2022
Occupancy Inspection - Codes Residential Temporary C of O 6/15/2022 6/15/2022 06/15/2022
Miscellaneous Correction
Corrective Action Required
06/15/2022
- Provide Through bolts on deck 2@1/2” On each post to beam connections - Security screws in hinges of exterior doors - Provide 6” clearance from Siding to grade TCO expiration 7/15/2022
Occupancy Inspection - Codes Residential Failed 8/12/2022 8/12/2022 08/12/2022
Miscellaneous Correction
Corrective Action Required
06/15/2022
- Provide Through bolts on deck 2@1/2” On each post to beam connections **not completed - Security screws in hinges of exterior doors **Cannot access house. Called for the code but phone was not answered **TCO expiration 7/15/2022. Payment must be paid for the extension of TCO
Occupancy Inspection - Codes Residential Full C of O 8/18/2022 8/18/2022 08/18/2022
Miscellaneous Correction
Resolved
08/18/2022
Documents & Images
Date Uploaded File Type Document Name
03/18/2021 37 WOODSIDE RIDGE ROOF LAYOUT
03/18/2021 W1 #37 - Palermo - Mediterranean - WO15x12C - Sheets- signed
03/18/2021 2686850 RF SEALS 02262021
03/18/2021 LOT 37 FINAL
03/18/2021 Approved Plans APPROVED TRUSS DRAWINGS
03/18/2021 Approved Plans APPROVED TRUSS LAYOUT
03/18/2021 Letter Codes Residential Plan Review
03/19/2021 W1 #37 - Permit App
03/19/2021 W1 #37 - Revised2 Palermo - Mediterranean - WO15x12C - Sheets- signed
03/19/2021 Application Form APPLICATION
03/19/2021 Approved Plans APPROVED PLANS
04/02/2021 LOT 37 CITY
04/02/2021 Plot Plan APPROVED PLOT PLAN
04/02/2021 Receipt Receipt for transaction:2021-001698
04/02/2021 Letter DS Building Permit
05/21/2021 W1-37 Woodside Ridge Footing Inspection
05/21/2021 Letter INSPECTION SUMMARY
05/21/2021 Letter INSPECTION SUMMARY
06/21/2021 Letter INSPECTION SUMMARY
06/21/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
11/23/2021 Letter INSPECTION SUMMARY
12/02/2021 Letter INSPECTION SUMMARY
01/06/2022 Letter INSPECTION SUMMARY
01/06/2022 Letter INSPECTION SUMMARY
01/06/2022 Letter INSPECTION SUMMARY
01/11/2022 Letter INSPECTION SUMMARY
01/31/2022 Letter INSPECTION SUMMARY
02/02/2022 Letter INSPECTION SUMMARY
02/08/2022 Letter INSPECTION SUMMARY
02/09/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
03/28/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
06/15/2022 Receipt Receipt for transaction:2022-004709
06/15/2022 Letter Codes Temporary Certificate of Occupancy
06/15/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
08/18/2022 Letter Field Certificate of Occupancy
08/18/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home