Permit Application Status

PRRES20211219


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211219
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK TILE ROOF
03/18/2021
03/24/2021
09/15/2021
06/23/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
MIKE@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/26/2021 03/24/2021
Kim Brennan
Basement opening elevations
Corrective Action Required
03/24/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. The MLOE's were taken off the front of the lot on the revised MDP
Residential Plan Review Approved 03/26/2021 03/24/2021
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
03/24/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) Not shown in unfinished basement
Plot Plan Review Rejected 03/22/2021 03/19/2021
Kim Brennan
Basement opening elevations
Corrective Action Required
03/19/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. The MLOE's were taken off the front of the lot on the revised MDP
Residential Plan Review Rejected 03/22/2021 03/19/2021
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
03/18/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) Not shown in unfinished basement
Planning Review (RES) Approved 03/22/2021 03/19/2021
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $955.67 $955.67 Paid 03/24/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/24/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/24/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 03/24/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 03/24/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 03/24/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/16/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/16/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/5/2021 05/05/2021
Erosion Control Inspection Residential Failed 5/7/2021 05/07/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/07/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - CLEAN STREET -
Underslab Plumbing Inspection - Residential Passed 6/17/2021 6/17/2021 06/17/2021
Sewer Service Inspection - R Passed 11/23/2021 11/23/2021
Water Service Inspection - R Passed 11/24/2021 (9:45) 11/24/2021 11/24/2021
All Rough Inspection - Residential Failed 12/7/2021 12/7/2021 12/07/2021
Misc
Corrective Action Required
12/07/2021
-Brace interior walls per plan -Provide attic access -2 anchors required for short plate at front -Have engineer address fix for broken top truss chord above garage; cut vertical member of A18 at bedroom/fireplace wall; kinked ends of all A trusses -Nail exterior wall sheathing to stud per code at rear of garage -Tie down all trusses to wall -Brace all trusses per plan -A18 girder truss: Nail together girder truss A18 per truss detail; support A18 at bedroom/fireplace wall; strap down A18 at bedroom/fireplace wall that can resist 1419 lbs of uplift and 548 lbs at dining wall end -Strap wall top plates lapped less than 24” in master closet, master bathroom -Solid block between trusses above front garage corner and master bathroom sink wall -Fb all wall plates penetrations; Fb dead space adjacent to master toilet/shower; Fb gap at back wall of fireplace space; Fb space at refrigerator -Vent all bathroom fans -Nail corner studs per code -Complete framing at fireplace and fasten fireplace to framing -Protect refrigerator water line -Support header joist above bottom stair landing; nail hanger -Complete framing per code below master bathroom toilet -The clothes washer drain cannot be used to wet-vent the master bath group. Wet-venting is for bathroom only **OK TO INSULATE
Electrical Service Inspection Passed 12/7/2021 12/7/2021 12/07/2021
Gas Service Inspection - Residential Failed 12/7/2021 12/7/2021 12/07/2021
Misc
Corrective Action Required
12/07/2021
-No pressure
Erosion Control Inspection Residential Failed 12/15/2021 12/15/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/07/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - CLEAN STREET -
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/15/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER
All Rough Inspection - Residential Failed 12/15/2021 12/15/2021 12/15/2021
Misc
Corrective Action Required
12/07/2021
-Brace interior walls per plan -Provide attic access -2 anchors required for short plate at front -Have engineer address fix for broken top truss chord above garage; cut vertical member of A18 at bedroom/fireplace wall; kinked ends of all A trusses -Nail exterior wall sheathing to stud per code at rear of garage -Tie down all trusses to wall -Brace all trusses per plan -A18 girder truss: Nail together girder truss A18 per truss detail; support A18 at bedroom/fireplace wall; strap down A18 at bedroom/fireplace wall that can resist 1419 lbs of uplift and 548 lbs at dining wall end -Strap wall top plates lapped less than 24” in master closet, master bathroom -Solid block between trusses above front garage corner and master bathroom sink wall -Fb all wall plates penetrations; Fb dead space adjacent to master toilet/shower; Fb gap at back wall of fireplace space; Fb space at refrigerator -Vent all bathroom fans -Nail corner studs per code -Complete framing at fireplace and fasten fireplace to framing -Protect refrigerator water line -Support header joist above bottom stair landing; nail hanger -Complete framing per code below master bathroom toilet -The clothes washer drain cannot be used to wet-vent the master bath group. Wet-venting is for bathroom only **OK TO INSULATE
Miscellaneous Correction
Corrective Action Required
12/15/2021
NO INSPECTION EROSION CONTROL FAILED - MAINTAIN SILT FENCE -
Gas Service Inspection - Residential Passed 12/20/2021 12/20/2021 12/20/2021
Misc
Resolved
12/20/2021
-No pressure
All Rough Inspection - Residential Not Ready 12/20/2021 12/20/2021 12/20/2021
Misc
Corrective Action Required
12/15/2021
-Brace interior walls per plan -2 anchors required for short plate at front -Have engineer address fix for broken top truss chord above garage; cut vertical member of A18 at bedroom/fireplace wall; kinked ends of all A trusses -Nail exterior wall sheathing to stud per code at rear of garage -Tie down all trusses to wall -Brace all trusses per plan -A18 per truss detail; support A18 at bedroom/fireplace wall; strap down A18 at bedroom/fireplace wall that can resist 1419 lbs of uplift and 548 lbs at dining wall end -Solid block between trusses above front garage corner and master bathroom sink wall -Fb all wall plates penetrations; Fb dead space adjacent to master toilet/shower; Fb gap at back wall of fireplace space; Fb space at refrigerator -Vent all bathroom fans -Nail corner studs per code -Complete framing at fireplace and fasten fireplace to framing -Support header joist above bottom stair landing; nail hanger -Complete framing per code below master bathroom toilet -The clothes washer drain cannot be used to wet-vent the master bath group. Wet-venting is for bathroom only - REPAIR DAMAGED DWV ENTRY BATH & LAUNDRY **OK TO INSULATE
Miscellaneous Correction
Resolved
12/20/2021
NO INSPECTION EROSION CONTROL FAILED - MAINTAIN SILT FENCE -
All Rough Inspection - Residential Not Ready 12/30/2021 12/30/2021 12/30/2021
Misc
Corrective Action Required
12/20/2021
-Brace interior walls per plan -2 anchors required for short plate at front -Have engineer address fix for broken top truss chord above garage; cut vertical member of A18 at bedroom/fireplace wall; kinked ends of all A trusses -Nail exterior wall sheathing to stud per code at rear of garage -Tie down all trusses to wall -Brace all trusses per plan -A18 per truss detail; support A18 at bedroom/fireplace wall; strap down A18 at bedroom/fireplace wall that can resist 1419 lbs of uplift and 548 lbs at dining wall end -Solid block between trusses above front garage corner and master bathroom sink wall -Fb all wall plates penetrations; Fb dead space adjacent to master toilet/shower; Fb gap at back wall of fireplace space; Fb space at refrigerator -Nail corner studs per code -Support header joist above bottom stair landing; nail hanger -Complete framing per code below master bathroom toilet **OK TO INSULATE
All Rough Inspection - Residential Passed 1/5/2022 1/5/2022 01/05/2022
Misc
Resolved
01/05/2022
Driveway Inspection Partial 1/14/2022 1/14/2022 01/14/2022
Misc
Informational
01/14/2022
Driveway forms and materials passed pre-inspection.
Driveway Inspection Passed 1/28/2022 1/28/2022 01/31/2022
Misc
Informational
01/14/2022
Driveway forms and materials passed pre-inspection.
Misc
Informational
01/31/2022
Driveway meets LS and Ada specs. 1/31/22 ES
Sidewalk Inspection Partial 3/24/2022 3/24/2022 03/24/2022
Misc
Informational
03/24/2022
Forms were placed and aggregate was present and compacted for the eastern sidewalk. They still need to do the western sidewalk. RP 3-24-22
Sidewalk Inspection Passed 4/1/2022 4/1/2022 04/01/2022
Misc
Informational
03/24/2022
Forms were placed and aggregate was present and compacted for the eastern sidewalk. They still need to do the western sidewalk. RP 3-24-22
Misc
Informational
04/01/2022
Finished sidewalk meets LS and ADA specs. RP 4-1-22
Erosion Control Inspection Residential Failed 4/20/2022 04/20/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/15/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - CLEAN STREET -
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/15/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
04/20/2022
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Plot Plan Inspection Passed 4/20/2022 04/20/2022
Occupancy Inspection - Codes Residential Failed 4/20/2022 4/20/2022 04/20/2022
Miscellaneous Correction
Corrective Action Required
04/20/2022
Pay not ready fees Obtain lawn irrigation permit & submit back flow certification Provide final grade Provide sod & splash blocks Seal top of exterior light fixtures Sump shall discharge 36" from foundation wall Provide guardrail front stoop over 30" to grade Garage entry door shall be self closing & self latching Remove dust covers smoke detectors Provide anti siphon device at water shut off Provide (2) 1/2" through bolts deck post to deck beam connection ( per 2018 IRC FIGURE R507.5.1(1)
Occupancy Inspection - Codes Residential Failed 6/20/2022 6/20/2022 06/20/2022
Miscellaneous Correction
Corrective Action Required
04/20/2022
Address Water meter leaking Garage entry door shall be self closing & SELF LATCHING
Erosion Control Inspection Residential Passed 6/23/2022 06/23/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/23/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - CLEAN STREET -
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/23/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
06/23/2022
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Occupancy Inspection - Codes Residential Full C of O 6/23/2022 6/23/2022 06/23/2022
Miscellaneous Correction
Resolved
06/23/2022
Documents & Images
Date Uploaded File Type Document Name
03/18/2021 Application Form Permit Application and License Tax Form
03/19/2021 Letter Codes Residential Plan Review
03/19/2021 Approved Plans Approved Drawings
03/19/2021 Approved Plans Approved Truss Layout
03/19/2021 Approved Plans Approved Truss Package
03/24/2021 Plot Plan Approved Plot Plan
03/24/2021 Receipt Receipt for transaction:2021-001484
03/24/2021 Letter DS Building Permit
05/05/2021 Letter INSPECTION SUMMARY
05/07/2021 Letter INSPECTION SUMMARY
06/17/2021 Letter INSPECTION SUMMARY
11/23/2021 Letter INSPECTION SUMMARY
11/23/2021 Letter INSPECTION SUMMARY
11/24/2021 Letter INSPECTION SUMMARY
12/07/2021 Letter INSPECTION SUMMARY
12/07/2021 Letter INSPECTION SUMMARY
12/07/2021 Letter INSPECTION SUMMARY
12/15/2021 Letter INSPECTION SUMMARY
12/15/2021 Letter INSPECTION SUMMARY
12/20/2021 Letter INSPECTION SUMMARY
12/20/2021 Letter INSPECTION SUMMARY
12/29/2021 2683768 REPAIR SEALS 12292021
12/29/2021 BCSI-B1
12/30/2021 Letter INSPECTION SUMMARY
01/05/2022 Letter INSPECTION SUMMARY
01/14/2022 Letter INSPECTION SUMMARY
01/31/2022 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
06/16/2022 Receipt Receipt for transaction:2022-004781
06/20/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter Codes Final Certificate of Occupancy
06/23/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home