Summary
PRRES20211218
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
03/18/2021
03/24/2021
09/15/2021
02/17/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JOSH@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/26/2021 03/24/2021
Kim Brennan
Basement opening elevations
Corrective Action Required
03/24/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. NO MBOE'S on the front are listed on the revised MDP
Residential Plan Review Approved 03/26/2021 03/24/2021
Kim Brennan
Planning Review (RES) Approved 03/22/2021 03/23/2021
Shannon McGuire
Plot Plan Review Rejected 03/22/2021 03/19/2021
Kim Brennan
Basement opening elevations
Corrective Action Required
03/18/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. NO MBOE'S on the front are listed on the revised MDP
Residential Plan Review Approved 03/22/2021 03/18/2021
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,266.08 $1,266.08 Paid 03/24/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/24/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/24/2021
8331507-Sewer Connection Fee $510.00 $510.00 Paid 03/24/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 03/24/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 03/24/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 01/17/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/17/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 01/17/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/11/2021 05/11/2021
Misc
Informational
05/11/2021
3RD PARTY FOOTING BY DEREK PEREZ @ RES SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED CENTER OF REAR GARAGE FOUNDATION WALL
Erosion Control Inspection Residential Failed 5/26/2021 05/26/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/26/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER CLEAN STREET
Underslab Plumbing Inspection - Residential Failed 5/26/2021 5/26/2021 05/26/2021
R506.2.5 Interior Underslab Drains
Corrective Action Required
05/26/2021
COMPLETE INTERIOR DRAIN TILE TO SUMP CONCRETE FLOORS (ON GROUND). ADDED 7-927. Where foundations retain earth and enclose habitable or usable space located below grade, drains shall be provi ded below the floor slab. Drainage tiles, perforated pipe or other approved systems or materials shall be installed at or below the area(s) to be protected; shall be placed with positive or neutral slope to minimize the accumulation of deposits in the drainage system; and shall discharge by gravity or mechanical means to an approved storm water drainage system. The underslab drainage system shall be installed around the inner perimeter of the area(s) to be protected, or, in a manner that will provide adequate drainage for all area(s) to be protected and is approved by the building official. Interior underslab drains installed on uncompacted fill material shall be supported by mechanical means which are adequately tied into the concrete slab to ensure proper drainage throughout the underslab drain(s).
Underslab Plumbing Inspection - Residential Passed 6/2/2021 6/2/2021 06/02/2021
R506.2.5 Interior Underslab Drains
Resolved
06/02/2021
COMPLETE INTERIOR DRAIN TILE TO SUMP CONCRETE FLOORS (ON GROUND). ADDED 7-927. Where foundations retain earth and enclose habitable or usable space located below grade, drains shall be provi ded below the floor slab. Drainage tiles, perforated pipe or other approved systems or materials shall be installed at or below the area(s) to be protected; shall be placed with positive or neutral slope to minimize the accumulation of deposits in the drainage system; and shall discharge by gravity or mechanical means to an approved storm water drainage system. The underslab drainage system shall be installed around the inner perimeter of the area(s) to be protected, or, in a manner that will provide adequate drainage for all area(s) to be protected and is approved by the building official. Interior underslab drains installed on uncompacted fill material shall be supported by mechanical means which are adequately tied into the concrete slab to ensure proper drainage throughout the underslab drain(s).
All Rough Inspection - Residential Failed 7/12/2021 7/12/2021 07/12/2021
Misc
Resolved
09/24/2021
All Rough Inspection - Residential Partial 7/12/2021 07/12/2021
Misc
Resolved
07/12/2021
: GARAGE PFH PORTAL FRAMING ONLY : OK TO COVER
Sewer Service Inspection - R Passed 8/4/2021 (11:15) 8/4/2021 08/04/2021
Water Service Inspection - R Passed 8/5/2021 (10:30) 8/5/2021 08/05/2021
Erosion Control Inspection Residential Failed 9/22/2021 09/22/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/26/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER CLEAN STREET
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/22/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER -
All Rough Inspection - Residential Failed 9/22/2021 9/22/2021 09/22/2021
Miscellaneous Correction
Resolved
09/24/2021
NO INSEPCTION NO CITY APPROVED PLANS ON SITE ONLY TRUSS PLANS
All Rough Inspection - Residential Failed 9/24/2021 9/24/2021 09/24/2021
Miscellaneous Correction
Resolved
09/24/2021
NO INSEPCTION NO CITY APPROVED PLANS ON SITE ONLY TRUSS PLANS
Miscellaneous Correction
Corrective Action Required
09/24/2021
Tighten anchor bolts garage Provide anchor bolts within 12" of plate break garage Provide anchor bolts at single car garage & end of plate south wall Anchor bolts shall be in middle 1/3 the width of plate Nail LIB garage Seal DWV top garage / pantry Nail studs at intersecting wall corners per code/plan sheet S1.0 #9 Insulate behind tub/shower enclosures on exterior walls Provide HUS26 hangers Bed 2 & master closet per truss plans Provide Boca plate master vanity Strap top plate bed 4 & laundry Provide 1" clearance single wall vent at furnace Insulate & solid block cantilever per plan above service panel Seal upward penetrations above door at stair landing Nail exterior wall sheathing per code
Electrical Service Inspection Passed 9/27/2021 9/27/2021 09/27/2021
Gas Service Inspection - Residential Passed 9/27/2021 9/27/2021 09/27/2021
All Rough Inspection - Residential Not Ready 9/28/2021 9/28/2021 09/28/2021
Miscellaneous Correction
Corrective Action Required
09/24/2021
Nail studs at intersecting wall corners per code/plan sheet S1.0 #9 ( Kitchen ) Insulate behind tub/shower enclosures on exterior walls Provide HUS26 hangers Bed 2 ( one hanger is HUS24 ) Provide Boca plate master vanity ( boca shall extend 2" above sole plate ) Provide 1" clearance single wall vent at furnace ( not done ) Insulate & solid block cantilever per plan above service panel
All Rough Inspection - Residential Passed 9/30/2021 9/30/2021 09/30/2021
Miscellaneous Correction
Resolved
09/30/2021
Driveway Inspection Partial 10/20/2021 10/20/2021 10/20/2021
Misc
Corrective Action Required
10/20/2021
Forms were placed and aggregate was present and compacted. Curb had chipped areas that need to be patched and grouted. 10/20 ES
Driveway Inspection Passed 10/29/2021 10/29/2021 10/29/2021
Misc
Corrective Action Required
10/20/2021
Forms were placed and aggregate was present and compacted. Curb had chipped areas that need to be patched and grouted. 10/20 ES
Misc
Informational
10/29/2021
Driveway meets LS spec. 10/29 ES
Occupancy Inspection - Codes Residential Failed 1/4/2022 1/4/2022 01/04/2022
Miscellaneous Correction
Corrective Action Required
01/04/2022
Pay not ready fees Submit back flow certification lawn irrigation permit Provide sod Provide splash blocks Sump shall discharge 36" from foundation Land sewer tracer wire in a box at grade Seal top of ac disconnect & gas line at meter Provide GFCI protection dishwasher Provide handrail basement stairway
Occupancy Inspection - Codes Residential Failed 1/19/2022 1/19/2022 01/19/2022
Miscellaneous Correction
Corrective Action Required
01/04/2022
Submit back flow certification Provide sod Provide splash blocks Sump shall discharge 36" from foundation Seal top of ac disconnect & gas line at meter Provide GFCI protection for dishwasher
Occupancy Inspection - Codes Residential Failed 1/27/2022 1/27/2022 01/27/2022
Miscellaneous Correction
Corrective Action Required
01/19/2022
Submit back flow certification Provide sod Provide splash blocks Sump shall discharge 36" from foundation Seal top of ac disconnect & gas line at meter Provide GFCI protection for dishwasher Checked 1/27/22 still not tripping breaker
Plot Plan Inspection Failed 2/1/2022 02/01/2022
Miscellaneous Correction
Corrective Action Required
02/01/2022
SUBMIT AS BUILT PLOT PLAN PER MASTER DRAINAGE PLAN
Occupancy Inspection - Codes Residential Temporary C of O 2/1/2022 2/1/2022 02/01/2022
Miscellaneous Correction
Corrective Action Required
01/27/2022
Provide sod Provide splash blocks Sump shall discharge 36" from foundation Seal top of ac disconnect & gas line at meter SUBMIT AS BUILT PLOT PLAN PER MASTER DRAINAGE PLAN
Plot Plan Inspection Passed 2/7/2022 2/7/2022 02/07/2022
Miscellaneous Correction
Resolved
02/07/2022
Occupancy Inspection - Codes Residential Full C of O 2/17/2022 2/17/2022 02/17/2022
Miscellaneous Correction
Resolved
02/17/2022
Documents & Images
Date Uploaded File Type Document Name
03/18/2021 Application Form Permit Application and License Tax Form
03/18/2021 2684908 RF SEAL 02252021
03/18/2021 Approved Plans Approved Drawings
03/18/2021 Approved Plans Approved Truss Layout
03/18/2021 Approved Plans Approved Truss Package
03/19/2021 Letter Codes Residential Plan Review
03/24/2021 Plot Plan Approved Plot Plan
03/24/2021 Receipt Receipt for transaction:2021-001485
03/24/2021 Letter DS Building Permit
05/11/2021 Lot 67 Woodside Ridge Footing Inspection
05/11/2021 Letter INSPECTION SUMMARY
05/26/2021 Letter INSPECTION SUMMARY
05/26/2021 Letter INSPECTION SUMMARY
06/02/2021 Letter INSPECTION SUMMARY
07/12/2021 Letter INSPECTION SUMMARY
08/04/2021 Letter INSPECTION SUMMARY
08/05/2021 Letter INSPECTION SUMMARY
09/22/2021 Letter INSPECTION SUMMARY
09/22/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
09/27/2021 Letter INSPECTION SUMMARY
09/27/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter INSPECTION SUMMARY
10/20/2021 Letter INSPECTION SUMMARY
10/29/2021 Letter INSPECTION SUMMARY
01/04/2022 Letter INSPECTION SUMMARY
01/17/2022 Receipt Receipt for transaction:2022-000285
01/19/2022 Letter INSPECTION SUMMARY
01/27/2022 Letter INSPECTION SUMMARY
02/01/2022 Letter INSPECTION SUMMARY
02/01/2022 Letter Codes Temporary Certificate of Occupancy
02/01/2022 LOT 67 ASBUILT ROUGH (002)
02/01/2022 Plot Plan Approved As-Graded Plot Plan
02/07/2022 Letter INSPECTION SUMMARY
02/17/2022 Letter Field Certificate of Occupancy
02/17/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home