Permit Application Status

PRRES20211217


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211217
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT - COVERED DECK
03/18/2021
03/29/2021
09/22/2021
01/21/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/30/2021 03/26/2021
Brandon Kalwei
Right-of-way
Corrective Action Required
03/26/2021

The right-of-way with dimensions must be provided on the plot plan.
Basement opening elevations
Corrective Action Required
03/26/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
Residential Plan Review Approved 03/30/2021 03/26/2021
Brandon Kalwei
Residential Plan Review Approved 03/22/2021 03/19/2021
Brandon Kalwei
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
03/18/2021

Identify roof covering material (IRC Section R905) Application shows no cement/tile roof, plans show tiled roof.
Plot Plan Review Rejected 03/22/2021 03/18/2021
Brandon Kalwei
Right-of-way
Corrective Action Required
03/18/2021

The right-of-way with dimensions must be provided on the plot plan.
Basement opening elevations
Corrective Action Required
03/18/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,066.44 $1,066.44 Paid 03/28/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 03/28/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/28/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/28/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 03/28/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 03/28/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/11/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/23/2021 04/23/2021
Misc
Informational
04/23/2021
3RD PARTY FOOTING BY DEREK PEREZ @ RES SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED SE REAR LEFT CORNER OF GARAGE FOUNDATION WALL
Underslab Plumbing Inspection - Residential Not Ready 5/10/2021 5/10/2021 05/10/2021
R506.2.5 Interior Underslab Drains
Corrective Action Required
05/10/2021
- PROVIDE ADDRESS - - INSTALL INTERIOR DRAIN TILE - CONCRETE FLOORS (ON GROUND). ADDED 7-927. Where foundations retain earth and enclose habitable or usable space located below grade, drains shall be provided below the floor slab. Drainage tiles, perforated pipe or other approved systems or materials shall be installed at or below the area(s) to be protected; shall be placed with positive or neutral slope to minimize the accumulation of deposits in the drainage system; and shall discharge by gravity or mechanical means to an approved storm water drainage system. The underslab drainage system shall be installed around the inner perimeter of the area(s) to be protected, or, in a manner that will provide adequate drainage for all area(s) to be protected and is approved by the building official. Interior underslab drains installed on uncompacted fill material shall be supported by mechanical means which are adequately tied into the concrete slab to ensure proper drainage throughout the underslab drain(s).
Erosion Control Inspection Residential Failed 5/14/2021 05/14/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/14/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - PROVIDE GRAVEL FILTER AT LOT ACCESS -
Underslab Plumbing Inspection - Residential Passed 5/14/2021 5/14/2021 05/14/2021
R506.2.5 Interior Underslab Drains
Resolved
05/14/2021
Electrical Service Inspection Passed 8/18/2021 8/18/2021 08/18/2021
Gas Service Inspection - Residential Passed 8/18/2021 8/18/2021 08/18/2021
All Rough Inspection - Residential Failed 8/18/2021 8/18/2021 08/18/2021
Miscellaneous Correction
Corrective Action Required
08/18/2021
Provide 4 studs GT bearing point entry coat closet per plan Provide LIB pantry per plan Seal upward penetrations pantry Nail exterior wall sheathing east side garage Tighten anchor bolts garage Strap over over bored top plate bed #2 interior load bearing wall Replace missing stud at tub bath #2 Provide 2 nails in LIBs top & bottom Seal upward penetration master shower pex Seal exterior penetration master shower Tighten anchor bolts basement Anchor bolts basement shall be in middle 1/3 of width of plate
All Rough Inspection - Residential Passed 8/31/2021 8/31/2021 08/31/2021
Miscellaneous Correction
Resolved
08/31/2021
Sewer Service Inspection - R Passed 9/9/2021 09/09/2021
Water Service Inspection - R Passed 9/13/2021 (10:30) 9/13/2021 09/13/2021
Driveway Inspection Partial 9/20/2021 9/20/2021 09/20/2021
Misc
Informational
09/20/2021
Forms are in place and rock is present and compacted. Right of way is in ADA spec.
Driveway Inspection Passed 9/24/2021 9/24/2021 09/24/2021
Misc
Informational
09/20/2021
Forms are in place and rock is present and compacted. Right of way is in ADA spec.
Misc
Informational
09/24/2021
Driveway is good and meets ADA spec
Sidewalk Inspection Partial 10/7/2021 10/7/2021 10/07/2021
Misc
Informational
10/07/2021
10-7-21 10:51 AN Forms are in place and aggregate is present and compacted
Sidewalk Inspection Passed 10/15/2021 10/15/2021 10/12/2021
Misc
Informational
10/07/2021
10-7-21 10:51 AN Forms are in place and aggregate is present and compacted
Misc
Informational
10/12/2021
10-12-21 AN sidewalk looks good and meets ADA specs
Occupancy Inspection - Codes Residential Failed 1/12/2022 1/12/2022 01/12/2022
Misc
Corrective Action Required
01/12/2022
-Final grade and sod -set water meter to grade, maintain 14”-18” clearance from top of meter to lid -complete spindles basement stairs -Install locking hardware sliding glass door, (2) locking devices required at sliding glass door -Garage door must be self closing -security screws at basement walkout -fireblock tub trap west side of basement
Plot Plan Inspection Passed 01/21/2022
Erosion Control Inspection Residential Passed 01/21/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
01/21/2022
Occupancy Inspection - Codes Residential Full C of O 1/21/2022 1/21/2022 01/21/2022
Misc
Corrective Action Required
01/12/2022
-set water meter to grade, maintain 14”-18” clearance from top of meter to lid
Documents & Images
Date Uploaded File Type Document Name
03/18/2021 Application Form APPLICATION
03/18/2021 22 WOODSIDE RIDGE ROOF LAYOUT
03/18/2021 LOT 22 FINAL
03/18/2021 W1 #22 - Florence - Mediterranean - Sheets- signed
03/18/2021 2694977 RF SEAL 03112021
03/18/2021 Approved Plans APPROVED TRUSS LAYOUT
03/18/2021 Approved Plans APPROVED TRUSS DRAWINGS
03/18/2021 Letter Codes Residential Plan Review
03/19/2021 W1 #22 - Permit App
03/19/2021 Approved Plans APPROVED PLANS
03/26/2021 LOT 22 CITY
03/26/2021 Plot Plan APPROVED PLOT PLAN
03/28/2021 Receipt Receipt for transaction:2021-001562
03/29/2021 Letter DS Building Permit
04/23/2021 W1-22 Woodside Ridge Footing inspection
04/23/2021 Letter INSPECTION SUMMARY
05/10/2021 Letter INSPECTION SUMMARY
05/14/2021 Letter INSPECTION SUMMARY
05/14/2021 Letter INSPECTION SUMMARY
08/18/2021 Letter INSPECTION SUMMARY
08/18/2021 Letter INSPECTION SUMMARY
08/18/2021 Letter INSPECTION SUMMARY
08/31/2021 Letter INSPECTION SUMMARY
09/09/2021 Letter INSPECTION SUMMARY
09/13/2021 Letter INSPECTION SUMMARY
09/20/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
10/07/2021 Letter INSPECTION SUMMARY
10/12/2021 Letter INSPECTION SUMMARY
01/11/2022 Receipt Receipt for transaction:2022-000190
01/11/2022 Receipt Receipt for transaction:2022-000191
01/12/2022 Letter INSPECTION SUMMARY
01/21/2022 Letter Codes Final Certificate of Occupancy
01/21/2022 Letter Field Certificate of Occupancy
01/21/2022 Letter INSPECTION SUMMARY
01/21/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home