Summary
PRRES20211111
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - FINISHED AND UNFINISHED BASEMENT - COVERED PORCH
03/12/2021
03/16/2021
09/12/2021
12/17/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/18/2021 03/16/2021
Brandon Kalwei
Sidewalks
Corrective Action Required
03/16/2021

Sidewalks with dimensions must be provided on the plot plan.
Residential Plan Review Approved 03/18/2021 03/16/2021
Brandon Kalwei
Plot Plan Review Rejected 03/16/2021 03/12/2021
Brandon Kalwei
Sidewalks
Corrective Action Required
03/12/2021

Sidewalks with dimensions must be provided on the plot plan.
Residential Plan Review Approved 03/16/2021 03/12/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $874.52 $874.52 Paid 03/16/2021
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid 03/16/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 03/16/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/16/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/16/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 03/16/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 03/16/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/20/2021 4/20/2021 04/20/2021
Underslab Plumbing Inspection - Residential Failed 4/29/2021 4/29/2021 04/29/2021
Misc
Corrective Action Required
04/29/2021
-CLEAN ALL MUD AND GRAVEL FROM STREET -CONTRACTOR BACKFILLING AT FOUNDATION AT TIME OF INSPECTION, UNABLE TO INSPECT ALL UNDERSLAB DWV -INTERIOR DRAIN TILE MUST REACH OPPOSITE FOUNDATION FOOTING FROM SUMP PIT WHEN DRAIN TILE LAYED HORIZONTALLY
Underslab Plumbing Inspection - Residential Passed 5/7/2021 5/7/2021 05/07/2021
Misc
Resolved
05/07/2021
All Rough Inspection - Residential Failed 5/27/2021 5/27/2021 05/27/2021
Misc
Corrective Action Required
05/27/2021
**APPROVED TRUSS PLANS/DRAWINGS REQUIRED ON SITE IF INSPECTING PORCH/DECK TRUSSES AT SAME TIME AS GARAGE PORTAL** **GARAGE PORTAL 5/27/21** - SEE IRC R602.10.6.2 -UNABLE TO INSPECT NAIL PATTERN FOR SHEATHING TO HEADER DUE TO COVER -HEADER TO JACK STRAPS REQUIRED, SEE TABLE R602.10.6.4 -NAIL HOLD DOWN STRAPS EMBEDDED IN CONCRETE TO SHEATHING -FASTEN PLATE TO HEADER WITH TWO ROWS 16D NAILS AT 3"O.C. -PANEL SPLICES EDGES SHALL OCCUR OVER AND BE NAILED TO COMMON BLOCKING WITHIN THE MIDDLE 24" OF THE PORTAL LEG. ONE ROW OF 3" O.C. NAILING REQ EACH SIDE PANEL
All Rough Inspection - Residential Failed 7/21/2021 7/21/2021 07/21/2021
Misc
Corrective Action Required
05/27/2021
-Seal all top plate penetrations -garage, front hall bath 1st floor -Install stud shoe DWV laundry/garage wall -add stud shoes and nail stud shoes master bath vanity -Fireblock between top plates at dbl walls master water closet -Bocca protection plate at bottom plate master water closet -Dbl top plate requires 24” offset between plate breaks, strap plates- see master bath above vanity, above fireplace in living room, -12” oc nailing at all abutting and intersecting wall corners -(3) studs at master bed east corner braced wall -truss hold downs front bed 1st floor -Fireblock gaps between top plates at dbl wall kitchen/bath wall -LIB bracing all locations per plans -Attic access in garage does not allow for access to full attic with sheathing blocking at dbl truss girder -(4) 2x4 stud packs required at all girder truss bearing ends per plans -steel beam at basement stairs less than 6’8” -fireblock vertical to horizontal at soffit ends of furred down basement den along south wall -security blocking at basement walkout -Protection plate at DWV bottom plate basement bath -Address floor joist cut for flue at furnace -(2) 2x10 headers at basement den windows per plans -(2) 2x10 header at basement bed#3 window per plans -(2) 1/2” through bolts at each post/beam connection per code at deck -Add angle clips at beam to ledger at deck -Nail exterior sheathing osb per plans
Electrical Service Inspection Passed 7/28/2021 7/28/2021 07/28/2021
Gas Service Inspection - Residential Passed 7/28/2021 7/28/2021 07/28/2021
All Rough Inspection - Residential Passed 7/28/2021 7/28/2021 07/28/2021
Misc
Resolved
07/28/2021
Sewer Service Inspection - R Passed 8/12/2021 (1:00) 8/12/2021 08/12/2021
Water Service Inspection - R Passed 8/16/2021 (9:00) 8/16/2021 08/16/2021
Misc
Informational
08/12/2021
PARTIAL PEX TO HOUSE ENTRANCE
Sidewalk Inspection Passed 9/9/2021 09/10/2021
Misc
Informational
09/10/2021
On Thursday September 9, 2021 I performed a sidewalk inspection and pass the subgrade to pour concrete
Driveway Inspection Passed 9/9/2021 09/10/2021
Misc
Informational
09/10/2021
On Thursday September 9, 2021 I performed a driveway inspection and pass the subgrade to pour concrete
Occupancy Inspection - Codes Residential Failed 10/22/2021 10/22/2021 10/22/2021
Misc
Corrective Action Required
10/22/2021
*obtain sprinkler permit* -Outlet under kitchen counter top need gfci - add splash blocks and extend sump pump discharge 36” from foundation -seal garage lighting at siding -secure A/c whip within 12” of disconnect -provide 6” between siding and grade -all protruding trim to be flashed
Occupancy Inspection - Codes Residential Temporary C of O 11/8/2021 11/8/2021 11/08/2021
Misc
Corrective Action Required
10/22/2021
TCO UNTIL 12/8/21 -seal garage lighting at siding -provide 6” between siding and grade -all protruding trim to be flashed
Occupancy Inspection - Codes Residential Full C of O 12/17/2021 12/17/2021
Misc
Resolved
12/17/2021
TCO UNTIL 12/8/21 -seal garage lighting at siding -provide 6” between siding and grade -all protruding trim to be flashed
Documents & Images
Date Uploaded File Type Document Name
03/12/2021 Application Form APPLICATION
03/12/2021 88 MANOR AT STONEY CREEK ROOF LAYOUT
03/12/2021 MN #88 - Charlotte - Craftsman - WO12x12C - Sheets- signed
03/12/2021 LOT 88 FINAL
03/12/2021 2685114 RF SEAL 03082021
03/12/2021 Approved Plans APPROVED PLANS
03/12/2021 Approved Plans APPROVED TRUSS DRAWINGS
03/12/2021 Approved Plans APPROVED TRUSS LAYOUT
03/12/2021 Letter Codes Residential Plan Review
03/16/2021 LOT 88 CITY
03/16/2021 Plot Plan APPROVED PLOT PLAN
03/16/2021 Receipt Receipt for transaction:2021-001312
03/16/2021 Letter DS Building Permit
04/19/2021 Lot 88 Stoney Creek footing inspection
04/20/2021 Letter INSPECTION SUMMARY
04/29/2021 Letter INSPECTION SUMMARY
05/07/2021 Letter INSPECTION SUMMARY
05/27/2021 Letter INSPECTION SUMMARY
07/21/2021 Letter INSPECTION SUMMARY
07/28/2021 Letter INSPECTION SUMMARY
07/28/2021 Letter INSPECTION SUMMARY
07/28/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/16/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
10/22/2021 Letter INSPECTION SUMMARY
10/25/2021 MN88 sprinkler permit
11/08/2021 Letter Codes Temporary Certificate of Occupancy
12/17/2021 Letter Field Certificate of Occupancy
12/17/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home