Summary
PRRES20210590
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT - TILE ROOF
02/12/2021
02/16/2021
08/15/2021
07/06/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/18/2021 02/16/2021
Brandon Kalwei
Lot elevations
Corrective Action Required
02/16/2021

Existing and finish elevations at all property corners must be provided on the plot plan. missing finish elevations on north side
Residential Plan Review Approved 02/18/2021 02/16/2021
Brandon Kalwei
Residential Plan Review Approved 02/17/2021 02/12/2021
Brandon Kalwei
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
02/12/2021

Identify roof covering material (IRC Section R905) Plans and application do not match, plans show tile roof
Plot Plan Review Rejected 02/17/2021 02/12/2021
Brandon Kalwei
Lot elevations
Corrective Action Required
02/12/2021

Existing and finish elevations at all property corners must be provided on the plot plan. missing finish elevations on north side
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $987.39 $987.39 Paid 02/16/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 02/16/2021
Right of Way Permit Fee $80.00 $80.00 Paid 02/16/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 02/16/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 02/16/2021
Water Meter Fee $455.54 $455.54 Paid 02/16/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/7/2021 (11:30) 5/7/2021 05/07/2021
Misc
Informational
05/07/2021
UFER LOCATED FOUNDATION WALL REAR OF GARAGE (2) PADS TO POUR WITH FOOTINGS @ COVERED DECK DETAIL J
Underslab Plumbing Inspection - Residential Passed 5/21/2021 5/21/2021 05/21/2021
Erosion Control Inspection Residential Failed 5/21/2021 05/21/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/21/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - PROVIDE GRAVEL FILTER AT LOT ACCESS - - MAINTAIN SILT FENCE - - CLEAN STREET OF ANY SEDIMENT, MUD, DIRT, & ROCK -
Sewer Service Inspection - R Passed 11/22/2021 11/22/2021 11/22/2021
Water Service Inspection - R Passed 11/23/2021 11/23/2021
Gas Service Inspection - Residential Failed 12/8/2021 12/8/2021 12/08/2021
Misc
Corrective Action Required
12/08/2021
-Complete fireplace installation
Gas Service Inspection - Residential Passed 1/13/2022 1/13/2022 01/13/2022
Misc
Resolved
01/13/2022
Erosion Control Inspection Residential Failed 1/20/2022 1/20/2022 01/20/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/21/2021
1-20-22 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - CLEAN STREET OF ANY SEDIMENT, MUD, DIRT, & ROCK -
Electrical Service Inspection Passed 1/20/2022 1/20/2022 01/20/2022
All Rough Inspection - Residential Failed 1/20/2022 1/20/2022 01/20/2022
Misc
Corrective Action Required
01/20/2022
-Restore erosion control at perimeter of lot and clean debris from street before any further inspection -Nail all framing members per detail at PFH sheathing -Uncover trusses st patio and porch for inspection -Unable to verify braced wall nailing pattern throughout -Block hip truss from top plate to sheathing at SE corner where block is short of truss and SW corner in garage, and NW corner -Provide 2 rows of 16d sinkers 3” OC at top plate to header at PFH per detail -Nail all corner and intersecting wall studs per code -Seal top plate penetrations throughout garage -Fireblock chase in garage -Provide 1” clearance to combustibles at B vent -Missing truss screw above 2 car door -Tighten anchor bolts in garage -Protect dwv 2” below top plate master bath -Seal gaps in dwv chase fireblocking by master -Missing truss screws at living room windows -Secure ward flex at fireplace -Bocca plates at bath 2 to extend 2” below plate -Fireblock tub traps -Missing truss hanger front bed -Complete CS-PF at dining room see detail R602.10.6.4 -Extend joist blocking under island 1 bay each way past island per plan -Address missing (2) 2x10 header at egress window -Label future vent in basement
All Rough Inspection - Residential Passed 2/16/2022 2/16/2022 02/16/2022
Misc
Resolved
02/16/2022
Driveway Inspection Partial 3/8/2022 03/08/2022
Misc
Informational
03/08/2022
Forms were placed and aggregate was present and compacted. RP 3-8-22
Driveway Inspection Passed 3/11/2022 3/11/2022 03/22/2022
Misc
Informational
03/08/2022
Forms were placed and aggregate was present and compacted. RP 3-8-22
Misc
Informational
03/22/2022
Finished driveway meets LS specs. RP 3-22-22
Plot Plan Inspection Passed 5/31/2022 05/31/2022
Piers/Caissons Inspection - Residential Passed 06/15/2022
Occupancy Inspection - Codes Residential Failed 5/31/2022 5/31/2022 06/15/2022
Miscellaneous Correction
Corrective Action Required
05/31/2022
No pier inspection on record detail J (2) 18x36 with (4) vertical # 4 Land conductors in a box with cover plate under great room windows GFCI covered patio no power Provide spark rings backsplash receptacles kitchen counter The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch garage ( 2018 IRC R311.7.5.1 GFCI receptacle at service panel no power Check AFCI breaker living room lights & plugs after great room complete Land sewer tracer wire in a box at grade level Lower water meter lid to grade level Top of water meter to pit lid shall be 14" to 18"
Occupancy Inspection - Codes Residential Temporary C of O 6/15/2022 6/15/2022 06/15/2022
Miscellaneous Correction
Corrective Action Required
05/31/2022
Lower water meter lid to grade level Top of water meter to pit lid shall be 14" to 18" ***TCO EXPIRES 7/15/2022***
Occupancy Inspection - Codes Residential Full C of O 7/6/2022 7/6/2022 07/06/2022
Miscellaneous Correction
Resolved
07/06/2022
Documents & Images
Date Uploaded File Type Document Name
02/12/2021 W1 #39 - Treviso - Mediterranean - F14x10C - Sheets- signed
02/12/2021 LOT 39 FINAL
02/12/2021 Letter Codes Residential Plan Review
02/12/2021 Application Form APPLICATION
02/16/2021 Plot Plan APPROVED PLOT PLAN
02/16/2021 Receipt Receipt for transaction:2021-000727
02/16/2021 Approved Plans APPROVED PLANS
02/16/2021 Letter DS Building Permit
03/08/2021 39 WOODSIDE RIDGE ROOF LAYOUT REVISED
03/08/2021 2630561 RF SEALS 02262021
03/08/2021 W1 #39 - Treviso - Mediterranean - F14x10C - A1-A5 REVISION- signed
03/08/2021 Approved Plans APPROVED TRUSS DRAWINGS
03/08/2021 Approved Plans APPROVED TRUSS LAYOUT
03/08/2021 Approved Plans supplimental approved plans
05/07/2021 Letter INSPECTION SUMMARY
05/21/2021 Letter INSPECTION SUMMARY
05/21/2021 Letter INSPECTION SUMMARY
09/21/2021 W1-39--A2 truss repair
11/17/2021 Letter Codes 180 Day Letter
11/22/2021 Letter INSPECTION SUMMARY
11/23/2021 Letter INSPECTION SUMMARY
12/08/2021 Letter INSPECTION SUMMARY
01/13/2022 Letter INSPECTION SUMMARY
01/20/2022 Letter INSPECTION SUMMARY
01/20/2022 Letter INSPECTION SUMMARY
01/20/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
06/06/2022 W1 39 - piers
06/15/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter Codes Temporary Certificate of Occupancy
07/06/2022 Letter Codes Final Certificate of Occupancy
07/06/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home