Permit Application Status

PRRES20210529


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210529
Building Permit - Residential
Certificate of Occupancy
NLV PERGOLA PARK LLC
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED AND UNCOVERED DECK SUSPENDED SLAB - ENGINEERED FLOOR JOISTS STOP WORK ORDER generated on 06/15/2021 12:00 AM by username 'John Morris'. STOP WORK ORDER removed on 06/17/2021 12:00 AM by username 'John Morris'.
02/08/2021
03/31/2021
08/07/2021
01/09/2024
Locations
Contacts
NLV PERGOLA PARK LLC, Address:3152 SW GRANDSTAND CIR  
LANDROCK SIGNATURE HOMES LLC, Address:4335 MCGEE ST, Phone:(816) 863-5588  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
JPROBERTS23@HOTMAIL.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/29/2021 03/25/2021
Kim Brennan
Legal description
Corrective Action Required
03/25/2021

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. This minor plat has not been approved yet. The address is also wrong and should be 3219 SW Pergonla Park Dr and not 3215.
Deck location
Corrective Action Required
03/25/2021

Deck location, with dimensions to property lines must be provided on the plot plan. Please show the covered deck
Misc
Corrective Action Required
03/25/2021

The bottom and top elevations of the retaining wall needs to be included.
Basement elevation
Corrective Action Required
03/25/2021

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.) The MDP calls for a daylight basement and not a walk-out
Residential Plan Review Approved 03/29/2021 03/25/2021
Kim Brennan
Residential Plan Review Approved 02/10/2021 02/10/2021
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
02/08/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) Not shown in unfinished basement
Plot Plan Review Rejected 02/10/2021 02/08/2021
Kim Brennan
Legal description
Corrective Action Required
02/08/2021

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. This minor plat has not been approved yet. The address is also wrong and should be 3219 SW Pergonla Park Dr and not 3215.
Deck location
Corrective Action Required
02/08/2021

Deck location, with dimensions to property lines must be provided on the plot plan. Please show the covered deck
Misc
Corrective Action Required
02/08/2021

The bottom and top elevations of the retaining wall needs to be included.
Basement elevation
Corrective Action Required
02/08/2021

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.) The MDP calls for a daylight basement and not a walk-out
Planning Review (RES) Approved 02/10/2021 02/08/2021
Victoria Nelson
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $2,358.98 $2,358.98 Paid 03/31/2021
$1,077.12
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/31/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 02/09/2021
$1,077.12
8331507-Sewer Connection Fee $870.00 $870.00 Paid 03/31/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 03/31/2021
7232302-New Longview Road and Bridge Escrow $1,077.12 $1,077.12 Paid 03/31/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 03/31/2021
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/08/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 6/2/2021 06/02/2021
Misc
Corrective Action Required
06/02/2021
-footing/column pad depths not per plan -retaining wall in SE corner not on approved house plans or approved plot plan -no foundation pier documentation on file and no third party inspection report on file
Foundation Inspection - Residential Failed - Stop Work 6/15/2021 6/15/2021 06/15/2021
Misc
Corrective Action Required
06/15/2021
-see failed footing inspection report from 6/2/21 regarding retaining wall not on any city approved documentation. Revise and resubmit plot plan for city approval
Foundation Inspection - Residential Failed 6/16/2021 (9:00) 6/16/2021 06/16/2021
Misc
Corrective Action Required
06/15/2021
-install reinforcement per concrete header detail, foundation opening under suspended slab -provide engineer documentation for retaining wall exceeding 4' in height
Footing Inspection - Residential Passed 6/15/2021 (3:00) 06/17/2021
Misc
Informational
06/17/2021
third party inspection with revised plot plan
Sewer Service Inspection - R Passed 7/12/2021 07/12/2021
Water Service Inspection - R Passed 7/13/2021 07/13/2021
Erosion Control Inspection Residential Failed 7/13/2021 7/13/2021 07/13/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/13/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Erosion Control Inspection Residential Failed 7/15/2021 07/15/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/13/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/15/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER -
Underslab Plumbing Inspection - Residential Passed 7/15/2021 7/15/2021 07/15/2021
All Rough Inspection - Residential Failed 11/11/2021 11/11/2021 11/11/2021
Miscellaneous Correction
Corrective Action Required
11/11/2021
INSPECTION DENIED NO ADDRESS POSTED WE WILL NOT PERFORM SEPARATE PORTAL FRAME INSPECTIONS - THESE WILL BE COMPLETEDAT THE ALL ROUGH 1ST INSPECTION
Electrical Service Inspection Passed 2/15/2022 2/15/2022 02/15/2022
Gas Service Inspection - Residential Passed 2/15/2022 2/15/2022 02/15/2022
All Rough Inspection - Residential Failed 2/15/2022 2/15/2022 02/15/2022
Miscellaneous Correction
Resolved
02/15/2022
Miscellaneous Correction
Corrective Action Required
02/15/2022
- Nail pattern 2x6 under header garage per plan - Floor penetration garage to mud room - Nail off intersecting corner north pantry - Security blocking at pantry entry - Security blocking at dining room door - Complete fire place Bvent - Seal penetration at fire place - Add stud shoes to over bored 2x4 in laundry 5 studs - Boca plate DWV master bathroom top plate - Fire block penetration floor master shower - Strap all vent pipe 2” or smaller to studs - Provide vent boot master bathroom - Add studs to LVL in foyer - Add studs at end of triple LVL in master bathroom - Fire block penetration floor gas line mechanical closet upstairs - Seal penetration floor at tub by entry - Fur out ductwork in closet upstairs - Fire block penetration top plate bedroom 4 - Provide roof boot bedroom 3 bathroom - Nail off hangers upstairs hall east side - Seal penetration of vents to outside bedroom 2 - Provide attic access second floor west side - Add strut to ridge beam west side of cat walk - Complete floor drain for garage under suspended slab - Provide 2 3” steel posts for basement - Add stud under double LVL basement south west side - Add studs to header left of windows on south west side basement - Provide joist hanger at header joist by door south west basement - Fire block penetration top plate basement laundry
All Rough Inspection - Residential Failed 2/17/2022 2/17/2022 02/17/2022
Miscellaneous Correction
Corrective Action Required
02/15/2022
- Floor penetration garage to mud room - Security blocking at pantry entry - Security blocking at dining room door - Complete fire place Bvent - Add stud shoes to over bored 2x4 in laundry 5 studs [ 1 missed ] - Complete floor drain for garage under suspended slab 2/17/22 additional corrections -provide hanger on header by stairs - protected water lines in kitchen soffit from freezing -fire stop fur out at top plate master bath vanity wall - complete venting for furnace second floor over garage -fur out rafters for insulation in cubbys over garage - missing joist hangers - provide 1 1/2" blocks on joist to rafter connections - over master rafter ties lower 1/3 at 4' o.c. - provide Great room main beam support 4 ft. O.C. or engineers correction - terminate all electrical on deck - provide protection for nailing electrical joist space at stairs
All Rough Inspection - Residential Failed 2/23/2022 2/23/2022 02/23/2022
Miscellaneous Correction
Corrective Action Required
02/17/2022
-Complete fire place Bvent threw roof OK TO INSULATE
Erosion Control Inspection Residential Failed 2/23/2022 02/23/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/23/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/23/2022
Miscellaneous Correction
Corrective Action Required
02/23/2022
Repair silt fence Remove debris from street
All Rough Inspection - Residential Passed 3/3/2022 3/3/2022 03/03/2022
Miscellaneous Correction
Resolved
03/03/2022
Driveway Inspection Partial 6/8/2022 6/8/2022 06/08/2022
Misc
Informational
06/08/2022
Driveway was framed up with aggregate in and compacted. 6/8/22 ES
Sidewalk Inspection Partial 6/8/2022 6/8/2022 06/08/2022
Misc
Informational
06/08/2022
Sidewalk was framed up with aggregate in and compacted. 6/8/22 ES East side of sidewalk was poured and meets LS and ADA specs. Remaining west side of sidewalk not poured/inspected. 6/20/22 ES
Driveway Inspection Passed 6/17/2022 6/17/2022 06/20/2022
Misc
Informational
06/08/2022
Driveway was framed up with aggregate in and compacted. 6/8/22 ES Driveway meets LS and ADA spec. 6/20/22 ES
Sidewalk Inspection Partial 6/17/2022 6/17/2022 06/20/2022
Misc
Informational
06/20/2022
Sidewalk was framed up with aggregate in and compacted. 6/8/22 ES East side of sidewalk was poured and meets LS and ADA specs. Remaining west side of sidewalk not poured/inspected. 6/20/22 ES
Piers/Caissons Inspection - Residential Passed 06/27/2022
Misc
Informational
06/27/2022
inspection done by third party.
Foundation Inspection - Residential Passed 06/27/2022
Misc
Resolved
06/27/2022
-install reinforcement per concrete header detail, foundation opening under suspended slab -provide engineer documentation for retaining wall exceeding 4' in height
Erosion Control Inspection Residential Failed 06/27/2022
Miscellaneous Correction
Corrective Action Required
02/23/2022
provide control at front of lot. Remove debris from street
Occupancy Inspection - Codes Residential Failed 6/27/2022 6/27/2022 06/27/2022
Misc
Corrective Action Required
06/27/2022
Remove dust covering smoke detectors Provide guard rail double door over garage Looks and secondary lock on all sliding doors Complete railing on deck off kitchen Land exposed electrical wiring Garage entry steps Garage door self closing and latch Garage door hardware Through bolts on beam to post connections on deck 2@1/2” Complete water heaters Complete electrical panels All GFCI outlets will be tested pending sidewalk inspection Provide gutters Final grading and sod Acquire irrigation permit and submit back flow certification Complete garage floor drain
Occupancy Inspection - Codes Residential Temporary C of O 6/28/2022 06/28/2022
Misc
Corrective Action Required
06/27/2022
Through bolts on beam to post connections on deck 2@1/2” pending sidewalk inspection Provide gutters Final grading and sod Acquire irrigation permit and submit back flow certification Complete garage floor drain bracket on post to beam connection at deck off of kitchen complete humidifier remove gauge from gas line TCO expiration 7/28/22
Sidewalk Inspection Partial 7/20/2022 7/20/2022 07/20/2022
Misc
Informational
06/20/2022
Sidewalk was framed up with aggregate in and compacted. 6/8/22 ES East side of sidewalk was poured and meets LS and ADA specs. Remaining west side of sidewalk not poured/inspected. 6/20/22 ES West side of sidewalk was framed up with aggregate in and compacted. 7/20/22 ES
Erosion Control Inspection Residential Passed 08/19/2022
Miscellaneous Correction
Resolved
08/19/2022
Plot Plan Inspection Passed 08/19/2022
Occupancy Inspection - Codes Residential Ready for Temp CO 8/19/2022 8/19/2022 08/19/2022
Misc
Corrective Action Required
06/28/2022
pending sidewalk inspection. I SETUP AN INSPECTION FOR MONDAY 8/22/22 Acquire irrigation permit and submit back flow certification bracket on post to beam connection at deck off of kitchen TCO expiration 7/28/22 Submit payment and fill out form for TCO extention.
Sidewalk Inspection Passed 8/22/2022 08/19/2022
Misc
Informational
07/20/2022
Sidewalk was framed up with aggregate in and compacted. 6/8/22 ES East side of sidewalk was poured and meets LS and ADA specs. Remaining west side of sidewalk not poured/inspected. 6/20/22 ES West side of sidewalk was framed up with aggregate in and compacted. 7/20/22 ES. Sidewalk meets LS and ADA spec. 8/19/22 ES
Occupancy Inspection - Codes Residential Full C of O 1/8/2024 1/10/2024 01/09/2024
Misc
Resolved
01/09/2024
TCO expiration 7/28/22 Submit payment
Documents & Images
Date Uploaded File Type Document Name
02/08/2021 Application Form Permit Application
02/08/2021 Application Form License Tax Form
02/08/2021 LOT 112 FINAL
02/08/2021 Letter Codes Residential Plan Review
02/10/2021 Approved Plans Approved Drawings
03/25/2021 Engineer Report/Study Engineer Letter for walkout
03/25/2021 Plot Plan Approved Plot Plan
03/31/2021 Receipt Receipt for transaction:2021-001643
03/31/2021 Letter DS Building Permit
06/02/2021 Letter INSPECTION SUMMARY
06/14/2021 Lot 112 Pergola Park Footing Inspection
06/14/2021 Lot 112 Pergola Park Pier Inspection
06/14/2021 112 Pergola Park Pier Plan-Final- signed
06/15/2021 Letter Stop Work Order
06/15/2021 Plot Plan Approved Revised Plot Plan
06/16/2021 Letter INSPECTION SUMMARY
06/17/2021 Letter INSPECTION SUMMARY
07/12/2021 Letter INSPECTION SUMMARY
07/13/2021 Letter INSPECTION SUMMARY
07/13/2021 Letter INSPECTION SUMMARY
07/15/2021 Letter INSPECTION SUMMARY
07/15/2021 Letter INSPECTION SUMMARY
11/11/2021 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
02/17/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
03/03/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/28/2022 Letter Codes Temporary Certificate of Occupancy
07/20/2022 Letter INSPECTION SUMMARY
08/19/2022 Letter INSPECTION SUMMARY
01/06/2023 Letter Codes 140 Day Letter
01/08/2024 Certificate/License Codes Temporary Certificate of Occupancy
01/08/2024 Receipt Receipt for transaction:2024-000135
01/09/2024 Letter Field Certificate of Occupancy
01/09/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home