Permit Application Status

PRRES20210507


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210507
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT WITH 60 SQ FEET FINISHED
02/05/2021
02/16/2021
08/09/2021
08/10/2022
Locations
Contacts
ROBERT A WASHAM CONSTRUCTION INC, Address:2058 NW SOUTH OUTER RD, Phone:(816) 224-5583  
LINDSAY@ROBWASHAMHOMES.COM  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/17/2021 02/12/2021
Kim Brennan
Residential Plan Review Approved 02/17/2021 02/12/2021
Kim Brennan
Miscellaneous Correction
Corrective Action Required
02/12/2021

DESIGN PROFESSIONAL MUST USE MISSOURI STAMP NOT KANSAS.
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
02/12/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315)
11 Designate R-value(s) for floors, walls, ceilings, roof/ceilings.
Corrective Action Required
02/12/2021

Designate R-value(s) for floors, walls, ceilings, roof/ceilings. (LSCO 7-802)
Plot Plan Review Approved 02/09/2021 02/11/2021
Dylan Eppert
City infrustructure
Corrective Action Required
02/10/2021

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. missing water valve and fire hydrant.
Residential Plan Review Rejected 02/09/2021 02/10/2021
Dylan Eppert
Miscellaneous Correction
Corrective Action Required
02/10/2021

DESIGN PROFESSIONAL MUST USE MISSOURI STAMP NOT KANSAS.
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
02/10/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315)
11 Designate R-value(s) for floors, walls, ceilings, roof/ceilings.
Corrective Action Required
02/10/2021

Designate R-value(s) for floors, walls, ceilings, roof/ceilings. (LSCO 7-802)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,506.64 $1,506.64 Paid 02/16/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/16/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 02/16/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 02/16/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 02/16/2021
8331507-Sewer Connection Fee $570.00 $570.00 Paid 02/16/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 4/21/2021 (11:30) 4/21/2021 04/21/2021
Misc
Corrective Action Required
04/21/2021
-Ensure proper footing depth throughout -Continuous corners required -Minimum 4 x 4 pier pads in garage
Footing Inspection - Residential Passed 4/21/2021 (1:00) 4/21/2021 04/21/2021
Misc
Resolved
04/21/2021
-Ensure proper footing depth throughout -Continuous corners required -Minimum 4 x 4 pier pads in garage
Sewer Service Inspection - R Failed 7/2/2021 (11:15) 7/2/2021 07/02/2021
Misc
Corrective Action Required
07/02/2021
-UNCOVER SEWER LINE AND PUT OUT WATER TO ALLOW FOR INSPECTION OF LINE AND CONNECTION TO SEWER MAIN
Sewer Service Inspection - R Passed 7/7/2021 (8:15) 7/7/2021 07/07/2021
Misc
Resolved
07/07/2021
Water Service Inspection - R Passed 7/7/2021 (1:00) 7/7/2021 07/07/2021
Underslab Plumbing Inspection - Residential Passed 7/13/2021 7/13/2021 07/13/2021
All Rough Inspection - Residential Partial 8/23/2021 8/23/2021 08/23/2021
Misc
Informational
08/23/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Erosion Control Inspection Residential Failed 8/23/2021 8/23/2021 08/23/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/23/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. CLEAN ALL MUD, GRAVEL, STRAW SWADDLE DEBRIS FROM STREET AT FRONT OF LOT
All Rough Inspection - Residential Failed 11/9/2021 11/9/2021 11/09/2021
Misc
Informational
08/23/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Corrective Action Required
11/09/2021
-maintain and bring erosion control into compliance, clean all and gravel from street, correct issues before rescheduling reinspection -security blocking at garage man door, master bedroom -solid block above beam between joists at garage, lateral restraint -add joist hanger at tail joist attic access garage, over 4’ -complete HVAC duct at furred down garage ceiling -fireblock HVAV/b vent chase garage -secure all vertical DWV 2” or less at mid point -12” oc nailing at intersecting corners -seal unused top plate bore at laundry -overbored stud for DWV, 1st floor front bedroom -add joist hangers to all ceiling joists 4’ or more at 1st floor master closet, 1st floor front bath, master bedroom 1st floor -add joist hanger at dbl joist to dbl joist connection at 1st floor front bath -Install outlets at 2nd floor hall/stairs per code -Install dbl joist hangers at ceiling box, 2nd floor bed#3 -nail rafters to parallel ceiling joists per plans -complete b vent roof termination at attic -T bracing roof 2nd floor loft per plans -Fireblock vertical to horizontal at furred down soffit ends finished basement -fireblock between top plate and foundation wall at finished basement -fireblock deadspace at shower basement bath -LIB bracing all locations per plans -CS-PF bracing per plans at dining room windows -EC#2 800 lb hold down device at dining room and master bed per plans -Nail all exterior sheathing per plans
Gas Service Inspection - Residential Passed 11/9/2021 11/9/2021 11/09/2021
Electrical Service Inspection Passed 11/9/2021 11/9/2021 11/09/2021
Erosion Control Inspection Residential Failed 11/9/2021 11/9/2021 11/09/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/23/2021
-maintain and bring erosion control into compliance, clean all and gravel from street, correct issues before rescheduling reinspection
All Rough Inspection - Residential Failed 11/17/2021 11/17/2021 11/17/2021
Misc
Informational
11/09/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Corrective Action Required
11/09/2021
-add joist hanger at tail joist attic access garage, over 4’ -seal unused top plate bore at laundry -Install outlets at 2nd floor hall/stairs per code -Install dbl joist hangers at ceiling box, 2nd floor bed#3 -nail rafters to parallel ceiling joists per plans -Fireblock vertical to horizontal at furred down soffit ends finished basement -fireblock between top plate and foundation wall at finished basement -fireblock deadspace at shower basement bath -CS-PF bracing per plans at dining room windows -Nail all exterior sheathing per plans
All Rough Inspection - Residential Failed 11/24/2021 11/24/2021 11/24/2021
Misc
Informational
11/17/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Corrective Action Required
11/17/2021
-Install outlets at 2nd floor hall/stairs per code
All Rough Inspection - Residential Passed 11/29/2021 11/29/2021 11/29/2021
Misc
Informational
11/24/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Corrective Action Required
11/24/2021
Sidewalk Inspection Passed 3/29/2022 3/29/2022 03/29/2022
Misc
Informational
03/29/2022
On Tuesday, 3-29-2022. I performed a sidewalk inspection and passed the forms and subgrade for concrete placement.
Driveway Inspection Passed 3/29/2022 3/29/2022 03/29/2022
Misc
Informational
03/29/2022
On Tuesday, 3-29-2022 I performed a driveway inspection and passed subgrade for placement of concrete.
Plot Plan Inspection Passed 4/29/2022 04/29/2022
Erosion Control Inspection Residential Failed 6/13/2022 06/13/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/13/2022
-maintain and bring erosion control into compliance, clean all and gravel from street, correct issues before rescheduling reinspection
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/13/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -clean dirt from street and sidewalk
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/13/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Failed 6/13/2022 6/13/2022 06/13/2022
Misc
Corrective Action Required
06/13/2022
-NO FURTHER INSPECTIONS UNTIL EROSION IS IN COMPLIANCE -obtain lawn irrigation permit -sod -check water meter after final sod -splash blocks and sump pump discharge to extend 36” from foundation -seal top of meter can, A/c disconnect and all other exterior penetrations Xcode -security screws at master to patio strike plates -secondary locking device at great room slider -both locking devices at dining room slider -complete outlet in great room floor -security screws at strike plate garage side door -basement bath not GFCI protected
Erosion Control Inspection Residential Failed 7/28/2022 07/28/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/13/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -clean dirt from street and sidewalk
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/13/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
07/28/2022
EROSION CONTROL STILL NOT IN PLACE. ESTABLISH EROSION CONTROL AND CLEAN UP STREET
Erosion Control Inspection Residential Passed 8/10/2022 08/10/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/10/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -clean dirt from street and sidewalk
DCM3 ESC REQUIRED 2 DAY
Resolved
08/10/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Resolved
08/10/2022
EROSION CONTROL STILL NOT IN PLACE. ESTABLISH EROSION CONTROL AND CLEAN UP STREET
Occupancy Inspection - Codes Residential Full C of O 8/10/2022 8/10/2022 08/10/2022
Misc
Resolved
08/10/2022
-NO FURTHER INSPECTIONS UNTIL EROSION IS IN COMPLIANCE -obtain lawn irrigation permit -sod -check water meter after final sod -splash blocks and sump pump discharge to extend 36” from foundation -seal top of meter can, A/c disconnect and all other exterior penetrations Xcode -security screws at master to patio strike plates -secondary locking device at great room slider -both locking devices at dining room slider -complete outlet in great room floor -security screws at strike plate garage side door -basement bath not GFCI protected
Documents & Images
Date Uploaded File Type Document Name
02/05/2021 19 Whispering Woods staked
02/05/2021 Residental Permit Application
02/05/2021 WW019 - TAX APPLICATION
02/10/2021 Letter Codes Residential Plan Review
02/12/2021 Approved Plans Approved Drawings
02/16/2021 Receipt Receipt for transaction:2021-000713
02/16/2021 Letter DS Building Permit
04/21/2021 Letter INSPECTION SUMMARY
04/21/2021 Letter INSPECTION SUMMARY
07/02/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter INSPECTION SUMMARY
07/13/2021 Letter INSPECTION SUMMARY
08/23/2021 Letter INSPECTION SUMMARY
08/23/2021 Letter INSPECTION SUMMARY
11/09/2021 Letter INSPECTION SUMMARY
11/09/2021 Letter INSPECTION SUMMARY
11/09/2021 Letter INSPECTION SUMMARY
11/09/2021 Letter INSPECTION SUMMARY
11/17/2021 Letter INSPECTION SUMMARY
11/24/2021 Letter INSPECTION SUMMARY
11/29/2021 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
04/28/2022 Plot Plan APPROVED AS BUILT PLOT PLAN
04/29/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter INSPECTION SUMMARY
07/28/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter Codes Final Certificate of Occupancy
08/10/2022 Letter Field Certificate of Occupancy
08/10/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: