Permit Application Status

PRRES20210156


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210156
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
01/12/2021
01/13/2021
07/11/2021
11/12/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JOSH@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/15/2021 01/13/2021
Kim Brennan
Residential Plan Review Approved 01/15/2021 01/13/2021
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
01/13/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) This information is missing in the guest suite
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
01/13/2021

Identify roof covering material (IRC Section R905) The application states a tile roof, however, the drawings show a composition roof. Please verify which one is correct.
Misc
Corrective Action Required
01/13/2021

Address must be listed on all pages of the drawings.
Plot Plan Review Approved 01/14/2021 01/13/2021
Kim Brennan
Deck location
Corrective Action Required
01/12/2021

Deck location, with dimensions to property lines must be provided on the plot plan.
Lot elevations
Corrective Action Required
01/12/2021

Existing and finish elevations at all property corners must be provided on the plot plan.
Planning Review (RES) Approved 01/14/2021 01/12/2021
Shannon McGuire
Residential Plan Review Rejected 01/14/2021 01/12/2021
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
01/12/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) This information is missing in the guest suite
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
01/12/2021

Identify roof covering material (IRC Section R905) The application states a tile roof, however, the drawings show a composition roof. Please verify which one is correct.
Misc
Corrective Action Required
01/12/2021

Address must be listed on all pages of the drawings.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,361.74 $1,361.74 Paid 01/13/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/13/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/13/2021
8331507-Sewer Connection Fee $570.00 $570.00 Paid 01/13/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 01/13/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 01/13/2021
Outstanding Fees Amount Paid Owing Date Paid
9110080-Not Ready Inspection Fee $50.00 $0.00 $50.00 Not Paid


$50.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/24/2021 03/15/2021
Misc
Informational
03/15/2021
- 3RD PARTY FOOTING BY DEREK PEREZ @ RES SIGNED & SEALED BY BRADLEY HUXOL - - UFER CENTER RIGHT OF NORTH GARAGE FOUNDATION WALL -
Underslab Plumbing Inspection - Residential Passed 3/22/2021 3/22/2021 03/22/2021
Gas Service Inspection - Residential Failed 6/7/2021 6/7/2021 06/07/2021
G2417.4.1 Test Pressure
Corrective Action Required
06/07/2021
- PROVIDE MIN 10 PSI FOR 15 MIN - INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
Electrical Service Inspection Passed 6/7/2021 6/7/2021 06/07/2021
All Rough Inspection - Residential Failed 6/7/2021 6/7/2021 06/07/2021
Miscellaneous Correction
Corrective Action Required
06/07/2021
No Deck pier inspection Provide truss lock screws south of fireplace, covered deck, master shower Provide min (4) 2x4 stud pack at GT bearing points per roof plan Solid block sheathing break PFH portal frame within middle 24" of wall per plan Provide LIB pantry per plan Insulate behind shower bath #2 Seal floor penetration dead space office Fire block office near ft door Seal upward penetration office closet Tighten anchor bolt east wall garage Nail strap VTR laundry Fire block dead space master water closet Replace stud bath #2 shower Replace fire block near deck door Tighten anchor bolts basement Provide anchor bolt within 12" of plate break Near patio door Anchor bolts shall be in middle 1/3 width of plate Provide 3 studs rear wall east & west corners Seal vertical to horizontal bath #4 & guest closet Provide stud shoe bed 4 bath vanity Provide flashing horizontal trim windows in office & foyer
Gas Service Inspection - Residential Passed 6/15/2021 6/15/2021 06/15/2021
G2417.4.1 Test Pressure
Corrective Action Required
06/07/2021
- PROVIDE MIN 10 PSI FOR 15 MIN - INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
All Rough Inspection - Residential Failed 6/15/2021 6/15/2021 06/15/2021
Miscellaneous Correction
Corrective Action Required
06/07/2021
*DO NOT INSULATE No Deck pier inspection Provide truss lock screws south of fireplace, covered deck, master shower Provide min (4) 2x4 stud pack at GT bearing points per roof plan- SW garage and latest room/foyer Solid block sheathing break PFH portal frame within middle 24" of wall per plan-seam to be in middle 24” of wall height-see detail 12 S2.0 Tighten anchor bolts basement-northwest corner at closet and tub Provide anchor bolt within 12" of plate break-end of plate behind tub Anchor bolts shall be in middle 1/3 width of plate-West wall Provide 3 studs rear wall east & west corners -provide plates and stud at corners of intersecting walls and nail pet code Provide stud shoe bed 4 bath vanity-both studs required Provide flashing horizontal trim windows in office & foyer
All Rough Inspection - Residential Failed 6/15/2021 6/15/2021 06/15/2021
Miscellaneous Correction
Corrective Action Required
06/15/2021
*DO NOT INSULATE Provide truss lock screws south of fireplace, covered deck, master shower Provide min (4) 2x4 stud pack at GT bearing points per roof plan- SW garage and latest room/foyer Solid block sheathing break PFH portal frame within middle 24" of wall per plan-seam to be in middle 24” of wall height-see detail 12 S2.0 Tighten anchor bolts basement-northwest corner at closet and tub Provide anchor bolt within 12" of plate break-end of plate behind tub Anchor bolts shall be in middle 1/3 width of plate-West wall Provide 3 studs rear wall east & west corners -provide plates and stud at corners of intersecting walls and nail pet code Provide stud shoe bed 4 bath vanity-both studs required Provide flashing horizontal trim windows in office & foyer
All Rough Inspection - Residential Passed 6/17/2021 6/17/2021 06/17/2021
Miscellaneous Correction
Resolved
06/17/2021
Sewer Service Inspection - R Passed 7/26/2021 07/26/2021
Water Service Inspection - R Passed 7/28/2021 07/28/2021
Sidewalk Inspection Partial 8/2/2021 8/2/2021 08/02/2021
Misc
Informational
08/02/2021
Forms were placed and aggregate was present and compacted. ADA Ramp is located just east of the driveway and wasn’t shown on the plot plan. RP 8-2-21
Driveway Inspection Partial 8/2/2021 8/2/2021 08/02/2021
Misc
Informational
08/02/2021
Forms were placed and aggregate was present and compacted. There is 2 water valves in the driveway approach. I informed them that we have to have access to them after they pour the approach. RP 8-2-21
Sidewalk Inspection Failed 8/6/2021 8/6/2021 08/06/2021
Misc
Informational
08/02/2021
Forms were placed and aggregate was present and compacted. ADA Ramp is located just east of the driveway and wasn’t shown on the plot plan. RP 8-2-21
Misc
Corrective Action Required
08/06/2021
Wrong concrete was used for the sidewalk. Needs to be removed and replaced with 4K KCMMB mix. RP 8-6-21
Driveway Inspection Failed 8/6/2021 8/6/2021 08/06/2021
Misc
Informational
08/02/2021
Forms were placed and aggregate was present and compacted. There is 2 water valves in the driveway approach. I informed them that we have to have access to them after they pour the approach. RP 8-2-21
Misc
Corrective Action Required
08/06/2021
Both water valve risers are busted. Need to remove and replace with new risers. RP 8-6-21
Occupancy Inspection - Codes Residential Not Ready 8/23/2021 8/23/2021 08/23/2021
Occupancy Inspection - Codes Residential Failed 8/30/2021 8/30/2021 08/30/2021
Miscellaneous Correction
Corrective Action Required
08/30/2021
Sidewalk inspection pending Driveway inspection pending No deck piers Sod & splash blocks Complete stone front of house Provide guardrail front stoop Install dishwasher Provide self closing door house to garage Remove dust covers smoke detectors Provide switch plate cover basement bathroom Provide guardrail front stoop over 30" to grade Seal top of meter can, ac disconnect, exterior light fixtures Seal low volt penetrations near meter Sump shall discharge 36" from foundation wall Provide (2) through bolts deck beam to post connection (attached Everstead letter says ledger locks, 2018 IRC figure R507.5.1(2) shows (2) 1/2 diameter through bolts or equivalent
Occupancy Inspection - Codes Residential Temporary C of O 9/7/2021 9/7/2021 09/07/2021
Miscellaneous Correction
Corrective Action Required
08/30/2021
Sidewalk inspection pending Driveway inspection pending Sod & splash blocks Provide guardrail front stoop over 30" to grade Sump shall discharge 36" from foundation wall
Sidewalk Inspection Partial 9/10/2021 9/10/2021 09/10/2021
Misc
Informational
08/06/2021
Forms were placed and aggregate was present and compacted. ADA Ramp is located just east of the driveway and wasn’t shown on the plot plan. RP 8-2-21
Misc
Corrective Action Required
08/06/2021
Wrong concrete was used for the sidewalk. Needs to be removed and replaced with 4K KCMMB mix. RP 8-6-21
Misc
Informational
09/10/2021
They removed the wrong concrete. Forms were placed and aggregate was present and compacted for the new sidewalk. RP 9-10-21
Sidewalk Inspection Passed 9/17/2021 9/17/2021 09/17/2021
Misc
Informational
09/10/2021
Forms were placed and aggregate was present and compacted. ADA Ramp is located just east of the driveway and wasn’t shown on the plot plan. RP 8-2-21
Misc
Corrective Action Required
09/10/2021
Wrong concrete was used for the sidewalk. Needs to be removed and replaced with 4K KCMMB mix. RP 8-6-21
Misc
Informational
09/10/2021
They removed the wrong concrete. Forms were placed and aggregate was present and compacted for the new sidewalk. RP 9-10-21
Misc
Informational
09/17/2021
Finished sidewalk meets LS and ADA specs. RP 9-17-21
Occupancy Inspection - Codes Residential Temporary C of O 9/27/2021 9/27/2021 09/27/2021
Miscellaneous Correction
Corrective Action Required
09/07/2021
Driveway inspection pending Address sinkhole front yard Water meter to meter pit lid 14" to 18" Paint gas line at meter
Driveway Inspection Failed 10/7/2021 10/7/2021 10/07/2021
Misc
Informational
08/06/2021
Forms were placed and aggregate was present and compacted. There is 2 water valves in the driveway approach. I informed them that we have to have access to them after they pour the approach. RP 8-2-21
Misc
Corrective Action Required
08/06/2021
Both water valve risers are busted. Need to remove and replace with new risers. RP 8-6-21
Misc
Corrective Action Required
10/07/2021
10-7-21 2:05 AN Water Department came out and inspected the water valves and determined that both the risers need to be replaced because they can’t get their valve key on the valves. —Need new taller riser that the valve cover sits on properly . No gaps between the cover and pipe. —Riser needs to be the approved pipe —Riser needs to be straight up and down, not at an angle.
Driveway Inspection Partial 10/20/2021 10/20/2021 10/20/2021
Misc
Informational
10/07/2021
Forms were placed and aggregate was present and compacted. There is 2 water valves in the driveway approach. I informed them that we have to have access to them after they pour the approach. RP 8-2-21
Misc
Corrective Action Required
10/07/2021
Both water valve risers are busted. Need to remove and replace with new risers. RP 8-6-21
Misc
Corrective Action Required
10/07/2021
10-7-21 2:05 AN Water Department came out and inspected the water valves and determined that both the risers need to be replaced because they can’t get their valve key on the valves. —Need new taller riser that the valve cover sits on properly . No gaps between the cover and pipe. —Riser needs to be the approved pipe —Riser needs to be straight up and down, not at an angle.
Misc
Corrective Action Required
10/20/2021
Redford removed the busted valve risers and installed new ductile iron risers. Needed to add 1 more form. sub-grade also needed digging out so they could get their required 4 inches of aggregate. RP 10-20-21
Driveway Inspection Passed 10/29/2021 10/29/2021 10/29/2021
Misc
Informational
10/20/2021
Forms were placed and aggregate was present and compacted. There is 2 water valves in the driveway approach. I informed them that we have to have access to them after they pour the approach. RP 8-2-21
Misc
Corrective Action Required
10/20/2021
Both water valve risers are busted. Need to remove and replace with new risers. RP 8-6-21
Misc
Corrective Action Required
10/20/2021
10-7-21 2:05 AN Water Department came out and inspected the water valves and determined that both the risers need to be replaced because they can’t get their valve key on the valves. —Need new taller riser that the valve cover sits on properly . No gaps between the cover and pipe. —Riser needs to be the approved pipe —Riser needs to be straight up and down, not at an angle.
Misc
Corrective Action Required
10/20/2021
Redford removed the busted valve risers and installed new ductile iron risers. Needed to add 1 more form. sub-grade also needed digging out so they could get their required 4 inches of aggregate. RP 10-20-21
Misc
Informational
10/29/2021
Driveway meets LS and Ada specs. 10/29 ES
Occupancy Inspection - Codes Residential Full C of O 11/12/2021 11/12/2021 11/12/2021
Miscellaneous Correction
Resolved
11/12/2021
Documents & Images
Date Uploaded File Type Document Name
01/12/2021 Application Form Permit Application and License Tax Form
01/12/2021 Letter Codes Residential Plan Review
01/13/2021 Plot Plan Approved Plot Plan
01/13/2021 Approved Plans Approved Truss Layout
01/13/2021 Approved Plans Approved Truss Package
01/13/2021 W0 #70 - Permit App
01/13/2021 Approved Plans Approved Drawings
01/13/2021 Receipt Receipt for transaction:2021-000177
01/13/2021 Letter DS Building Permit
03/15/2021 Lot 70 Woodside Ridge Footing Inspection
03/15/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
04/20/2021 Approved Plans Approved Revised Truss Package
06/07/2021 Letter INSPECTION SUMMARY
06/07/2021 Letter INSPECTION SUMMARY
06/07/2021 Letter INSPECTION SUMMARY
06/15/2021 Letter INSPECTION SUMMARY
06/15/2021 Letter INSPECTION SUMMARY
06/15/2021 Letter INSPECTION SUMMARY
06/17/2021 Letter INSPECTION SUMMARY
07/26/2021 Letter INSPECTION SUMMARY
07/28/2021 Letter INSPECTION SUMMARY
07/28/2021 Letter INSPECTION SUMMARY
08/02/2021 Letter INSPECTION SUMMARY
08/02/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
08/23/2021 Letter INSPECTION SUMMARY
08/24/2021 70 Woodside Ridge deck post letter
08/30/2021 Letter INSPECTION SUMMARY
09/07/2021 Letter Codes Temporary Certificate of Occupancy
09/10/2021 Letter INSPECTION SUMMARY
09/17/2021 Letter INSPECTION SUMMARY
09/27/2021 Letter Codes Temporary Certificate of Occupancy
10/07/2021 Letter INSPECTION SUMMARY
10/20/2021 Letter INSPECTION SUMMARY
10/29/2021 Letter INSPECTION SUMMARY
11/12/2021 Letter Codes Final Certificate of Occupancy
11/12/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home