Permit Application Status

PRRES20210101


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210101
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ENGINEERED FLOOR SYSTEM ( DEFERRED) - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
01/07/2021
01/14/2021
07/10/2021
07/01/2022
Locations
Contacts
PFEIFER HOMES INC, Address:1550 SW MARKET ST STE 210, Phone:(816) 524-5245  
AUBREY@PFEIFERHOMES.COM  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/13/2021 01/11/2021
Brandon Kalwei
Deck location
Corrective Action Required
01/11/2021

Deck location, with dimensions to property lines must be provided on the plot plan.
Residential Plan Review Approved 01/13/2021 01/11/2021
Brandon Kalwei
Residential Plan Review Approved 01/12/2021 01/08/2021
Brandon Kalwei
30 Identify type of protection used in unfinished areas under
Corrective Action Required
01/08/2021

Identify type of protection used in unfinished areas under floor trusses. (IRC Section R501.3)
Plot Plan Review Rejected 01/12/2021 01/08/2021
Brandon Kalwei
Deck location
Corrective Action Required
01/08/2021

Deck location, with dimensions to property lines must be provided on the plot plan.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,215.50 $1,215.50 Paid 01/14/2021
8331507-Sewer Connection Fee $510.00 $510.00 Paid 01/14/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/14/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/14/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 01/14/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 01/14/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 04/15/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 04/15/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 04/15/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/22/2021 (1:30) 1/22/2021 01/22/2021
Misc
Informational
01/22/2021
- PROVIDE ADDRESS - - UFER NW CORNER -
Sewer Service Inspection - R Passed 3/1/2021 (10:45) 3/1/2021 03/01/2021
Erosion Control Inspection Residential Failed 3/2/2021 03/02/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/02/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - PROVIDE ADDRESS -
Underslab Plumbing Inspection - Residential Failed 3/2/2021 3/2/2021 03/02/2021
Misc
Corrective Action Required
03/02/2021
- PROVIDE UNDERSLAB PERIMETER DRAIN TILE - - PROVIDE ADDRESS -
Water Service Inspection - R Passed 3/4/2021 03/04/2021
Misc
Corrective Action Required
03/04/2021
PROVIDE ADDRESS
Driveway Inspection Partial 8/30/2021 08/30/2021
Misc
Informational
08/30/2021
Forms were placed and aggregate was present and compacted. RP 8-30-21
Piers/Caissons Inspection - Residential Failed 9/1/2021 9/1/2021 09/01/2021
Miscellaneous Correction
Corrective Action Required
09/01/2021
PROVIDE DECK PIERS PER PLAN (2) PIER K 24" X 36" (1) PIER J 18" X 36" PUMP WATER FROM PIERS
Piers/Caissons Inspection - Residential Passed 9/2/2021 (2:00) 9/2/2021 09/02/2021
Miscellaneous Correction
Resolved
09/02/2021
PROVIDE DECK PIERS PER PLAN (2) PIER K 24" X 36" (1) PIER J 18" X 36" OK TO POUR
Driveway Inspection Passed 9/10/2021 9/10/2021 09/10/2021
Misc
Informational
08/30/2021
Forms were placed and aggregate was present and compacted. RP 8-30-21
Misc
Informational
09/10/2021
Finished driveway meets LS specs. RP 9-10-21
Erosion Control Inspection Residential Failed 10/5/2021 10/05/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/02/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - PROVIDE ADDRESS -
DCM5 ESC INSP DENIED
Corrective Action Required
10/05/2021
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER
All Rough Inspection - Residential Failed 10/5/2021 10/5/2021 10/05/2021
Misc
Corrective Action Required
10/05/2021
INSPECTION DENIED FAILED EROSION CONTROL NO SILT FENCE
Electrical Service Inspection Passed 10/8/2021 10/8/2021 10/08/2021
Gas Service Inspection - Residential Passed 10/8/2021 10/8/2021 10/08/2021
All Rough Inspection - Residential Failed 10/8/2021 10/8/2021 10/08/2021
Misc
Resolved
10/08/2021
INSPECTION DENIED FAILED EROSION CONTROL NO SILT FENCE
Miscellaneous Correction
Corrective Action Required
10/08/2021
Complete chase garage Furr out supply air garage/kitchen for insulation Provide anchor bolts schedule 40 columns basement Support stair stringers with Simpson LS70 hangers per plan Protect NM conductors penetrating floor at kitchen island Provide midpoint support vertical DWV 2" & smaller Provide solid security blocking deck door anchor bolts shall land in middle 1/3 the width of plate throughout Unable to verify sheathing to header nail pattern PFG portal garage Provide header to jack stud straps garage PFG portal frame per plan Fasten top plate to header with two rows of 16d sinkers at 2" OC per plan PFG portal Solid block spliced edges and nail per plan PFG portal Provide anchor bolts within 12" of plate break garage south wall under beam Provide 6 studs under garage beam per plan Provide 7 studs under beam at dead space kitchen/garage per plan Provide 2 studs under ridge beam kitchen/garage per plan Seal bottom plate penetrations at oven Provide rafter ties at ceiling joist perpendicular to rafters per plan Nail studs at intersecting wall corners per plan Provide hangers at triple joist great room @ LVL Seal floor penetrations at fireplace Seal dead space at master/ radius stairs Fire block dead space behind master shower Seal low volt penetrations master closet Solid block & nail sheathing breaks office & front door Provide anchor bolts SE & NE corners bed #4 & bed # 2 Fire block soffit above wet bar Fire block soffit at game area Provide 8 studs per plan game/ rec area Tighten anchor bolts garage & basement
All Rough Inspection - Residential Not Ready 10/18/2021 10/18/2021 10/18/2021
Miscellaneous Correction
Corrective Action Required
10/08/2021
Support stair stringers with Simpson LS70 hangers per plan Protect NM conductors penetrating floor at kitchen island Provide solid security blocking deck door anchor bolts shall land in middle 1/3 the width of plate throughout Unable to verify sheathing to header nail pattern PFG portal garage Fasten top plate to header with two rows of 16d sinkers at 2" OC per plan PFG portal Provide rafter ties at ceiling joist perpendicular to rafters per plan Nail studs at intersecting wall corners per plan Provide hangers at triple joist great room @ LVL Fire block dead space behind master shower Solid block & nail sheathing breaks office & front door Provide anchor bolts SE & NE corners bed #4 & bed # 2 Fire block soffit above wet bar Fire block soffit at game area Provide 8 studs per plan game/ rec area SECURE NM AT STUD ADDED UNDER RIDGE BEAM KITCHEN/GARAGE
Plot Plan Inspection Passed 10/28/2021 10/28/2021
Erosion Control Inspection Residential Failed 10/28/2021 10/28/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/05/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - PROVIDE ADDRESS -
DCM5 ESC INSP DENIED
Corrective Action Required
10/05/2021
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/28/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE UNTIL SOD COMPLETE -
All Rough Inspection - Residential Failed 10/28/2021 10/28/2021 10/28/2021
Miscellaneous Correction
Corrective Action Required
10/18/2021
Support stair stringers with Simpson LS70 hangers per plan Protect NM conductors penetrating floor at kitchen island Provide solid security blocking deck door anchor bolts shall land in middle 1/3 the width of plate throughout Unable to verify sheathing to header nail pattern PFG portal garage Fasten top plate to header with two rows of 16d sinkers at 2" OC per plan PFG portal Provide rafter ties at ceiling joist perpendicular to rafters per plan Nail studs at intersecting wall corners per plan Provide hangers at triple joist great room @ LVL Fire block dead space behind master shower Solid block & nail sheathing breaks office & front door Provide anchor bolts SE & NE corners bed #4 & bed # 2 Fire block soffit above wet bar Fire block soffit at game area Provide 8 studs per plan game/ rec area SECURE NM AT STUD ADDED UNDER RIDGE BEAM KITCHEN/GARAGE UNDERSLAB PLUMBING FAILED
Misc
Corrective Action Required
10/28/2021
NO SILT FENCE EROSION CONTROL FAILED NO INSPECTIONS UNTIL SILT FENCE IN PLACE NO ACCESS HOUSE LOCKED CALLED RICK @ 10:41 LEFT MESSAGE NEVER CALLED ME BACK
All Rough Inspection - Residential Not Ready 11/1/2021 11/1/2021 11/01/2021
Miscellaneous Correction
Corrective Action Required
10/28/2021
anchor bolts shall land in middle 1/3 the width of plate throughout Provide rafter ties at ceiling joist perpendicular to rafters per plan Provide anchor bolts SE & NE corners bed #4 & bed # 2 Fire block soffit above wet bar Fire block soffit at game area : UNDERSLAB PLUMBING FAILED :
Misc
Resolved
11/01/2021
NO SILT FENCE EROSION CONTROL FAILED NO INSPECTIONS UNTIL SILT FENCE IN PLACE NO ACCESS HOUSE LOCKED CALLED RICK @ 10:41 LEFT MESSAGE NEVER CALLED ME BACK
All Rough Inspection - Residential Passed 11/3/2021 11/3/2021 11/03/2021
Miscellaneous Correction
Corrective Action Required
11/01/2021
: UNDERSLAB PLUMBING FAILED :
Erosion Control Inspection Residential Failed 3/28/2022 03/28/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/28/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - PROVIDE ADDRESS -
DCM5 ESC INSP DENIED
Corrective Action Required
10/28/2021
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/28/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE UNTIL SOD COMPLETE -
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/28/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE UNTIL SOD COMPLETE
Occupancy Inspection - Codes Residential Failed 3/28/2022 3/28/2022 03/28/2022
Miscellaneous Correction
Corrective Action Required
03/28/2022
Obtain lawn irrigation permit & submit back flow certification Under slab plumbing failed 3/2/21 Pay not ready fees Provide ceiling light fixture powder room at garage door Label non GFCI receptacles garage No power GFCI @ covered deck Seal exterior penetration at gas line covered deck A 4" sphere shall not pass through deck railing Install master bath tub Provide wet rated fixture above master tub Secure switches & provide cover plate at master shower Secure metal box & protect NM conductors wet bar basement Provide light fixture south bedroom closet in basement Provide (2) 1/2 through bolts deck beam to post connection ( PER 2018 IRC FIGURE R507.5.1(2) Post permanent address Provide sod Provide gutters & downspouts Provide splash blocks Provide final grade Remove Constuction debris from job site & contain trash
Occupancy Inspection - Codes Residential Not Ready 4/14/2022 4/14/2022 04/14/2022
Miscellaneous Correction
Corrective Action Required
03/28/2022
Obtain lawn irrigation permit & submit back flow certification Under slab plumbing failed 3/2/21 Pay not ready fees Provide wet rated fixture above master tub ( per 2018 IRC E4003.11) Provide (2) 1/2 through bolts deck beam to post connection ( PER 2018 IRC FIGURE R507.5.1(2) Provide splash blocks
Occupancy Inspection - Codes Residential Temporary C of O 4/20/2022 04/20/2022
Miscellaneous Correction
Corrective Action Required
04/14/2022
Obtain lawn irrigation permit & submit back flow certification
Occupancy Inspection - Codes Residential Full C of O 7/1/2022 07/01/2022
Miscellaneous Correction
Resolved
07/01/2022
Documents & Images
Date Uploaded File Type Document Name
01/07/2021 Application Form APPLICATION
01/07/2021 Application Form excise tax
01/07/2021 Sealed Plot Plan - Troy Approved - Lot 77 WR
01/08/2021 Letter Codes Residential Plan Review
01/08/2021 Approved Plans APPROVED PLANS
01/11/2021 Plot Plan APPROVED PLOT PLAN
01/14/2021 Receipt Receipt for transaction: 2021-000213
01/14/2021 Letter DS Building Permit
01/22/2021 Letter INSPECTION SUMMARY
03/01/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/04/2021 Letter INSPECTION SUMMARY
08/30/2021 Letter INSPECTION SUMMARY
09/01/2021 Letter INSPECTION SUMMARY
09/02/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
10/05/2021 Letter INSPECTION SUMMARY
10/05/2021 Letter INSPECTION SUMMARY
10/08/2021 Letter INSPECTION SUMMARY
10/08/2021 Letter INSPECTION SUMMARY
10/08/2021 Letter INSPECTION SUMMARY
10/18/2021 Letter INSPECTION SUMMARY
10/28/2021 Letter INSPECTION SUMMARY
10/28/2021 Letter INSPECTION SUMMARY
11/01/2021 Letter INSPECTION SUMMARY
11/03/2021 Letter INSPECTION SUMMARY
11/11/2021 Letter INSPECTION SUMMARY
03/23/2022 Letter Codes 140 Day Letter
03/28/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
04/15/2022 Receipt Receipt for transaction: 2022-002109
04/18/2022 SKMBT_C284e22041723590
04/18/2022 329 Drain Tile invoice
04/20/2022 Letter Codes Temporary Certificate of Occupancy
07/01/2022 Letter Codes Final Certificate of Occupancy
07/01/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home