Permit Application Status

PRRES20204938


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20204938
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
12/28/2020
03/03/2021
07/11/2021
06/30/2022
Locations
Contacts
KC CUSTOM HOMES, Address:406 NW DONOVAN RD, Phone:(816) 564-5149  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
THE SOLAR GUYS, Address:6114 MO-9 HWY STE C1, Phone:(913) 424-2112  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
steve@kc-customhomes.com  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/14/2021 01/12/2021
Brandon Kalwei
Residential Plan Review Approved 01/14/2021 01/12/2021
Brandon Kalwei
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
01/12/2021

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) need to put unfinished basement sq. footage on the plans.
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
01/12/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315)
16 Identify location(s) of vertical supports and purlins.
Corrective Action Required
01/12/2021

Identify location(s) of vertical supports and purlins. (IRC Section R802.5.1)
21 Foundation wall thickness and height and reinforcement.
Corrective Action Required
01/12/2021

Foundation wall thickness and height and reinforcement. (IRC Section R404)
36 Identify interior load bearing walls.
Corrective Action Required
01/12/2021

Identify interior load bearing walls. (IRC Section R602)
33 Identify braced wall locations and length of braced wall panel(s).
Corrective Action Required
01/12/2021

Identify braced wall locations and length of braced wall panel(s). (IRC Section R602.10)
34 Specify type of wall bracing method(s) utilized.
Corrective Action Required
01/12/2021

Specify type of wall bracing method(s) utilized. (IRC Section R602.10)
Plot Plan Review Approved 12/30/2020 12/30/2020
Brandon Kalwei
Rear yard dimension
Corrective Action Required
12/28/2020

The rear yard demision(s) must be provided on the plot plan.
Deck location
Corrective Action Required
12/28/2020

Deck location, with dimensions to property lines must be provided on the plot plan.
Basement egress
Corrective Action Required
12/28/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
Residential Plan Review Rejected 12/30/2020 12/28/2020
Brandon Kalwei
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
12/28/2020

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) need to put unfinished basement sq. footage on the plans.
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
12/28/2020

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315)
16 Identify location(s) of vertical supports and purlins.
Corrective Action Required
12/28/2020

Identify location(s) of vertical supports and purlins. (IRC Section R802.5.1)
21 Foundation wall thickness and height and reinforcement.
Corrective Action Required
12/28/2020

Foundation wall thickness and height and reinforcement. (IRC Section R404)
36 Identify interior load bearing walls.
Corrective Action Required
12/28/2020

Identify interior load bearing walls. (IRC Section R602)
33 Identify braced wall locations and length of braced wall panel(s).
Corrective Action Required
12/28/2020

Identify braced wall locations and length of braced wall panel(s). (IRC Section R602.10)
34 Specify type of wall bracing method(s) utilized.
Corrective Action Required
12/28/2020

Specify type of wall bracing method(s) utilized. (IRC Section R602.10)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,786.04 $1,786.04 Paid 03/03/2021
8331507-Sewer Connection Fee $690.00 $690.00 Paid 03/03/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/03/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/03/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 03/03/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 03/03/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/16/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/16/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/3/2021 (11:30) 3/3/2021 03/03/2021
Misc
Informational
03/03/2021
- POST ADDRESS - - UFER NORTH & SOUTH FOUNDATION WALLS WEST SIDE -
Sewer Service Inspection - R Passed 3/29/2021 (8:30) 3/29/2021 03/29/2021
Underslab Plumbing Inspection - Residential Passed 3/30/2021 3/30/2021 03/30/2021
Water Service Inspection - R Passed 3/31/2021 (8:00) 3/30/2021 03/30/2021
Piers/Caissons Inspection - Residential Passed 6/23/2021 06/23/2021
Misc
Informational
06/23/2021
3RD PARTY DECK PIERS BY KEVIN MILLER @ APEX SIGNED & SEALED BY CLAYTON HESS (3) 24 X 36
All Rough Inspection - Residential Failed 8/9/2021 8/9/2021 08/09/2021
Misc
Corrective Action Required
08/09/2021
NO CITY APPROVED PLANS ON SITE NOT READY FOR ALL ROUGH
All Rough Inspection - Residential Failed 8/13/2021 8/13/2021 08/13/2021
Misc
Resolved
08/13/2021
NO CITY APPROVED PLANS ON SITE NOT READY FOR ALL ROUGH
Miscellaneous Correction
Corrective Action Required
08/13/2021
Provide 5/8 anchor bolts with double bottom plate per plan detail A1 Provide header to jack stud straps portal framing garage Fasten top plate to header with 2 rows 16d sinkers at 3" OC portal frame garage Provide anchor bolts within 12" of plate break & ends of plate Tighten anchor bolts garage Solid block sheathing breaks and nail per code Provide midpoint support vertical DWV 2" & smaller Seal all upward & exterior penetrations throughout Provide anchor bolts SCH 40 columns Land conductors in a box Install service panel Fire block chases in garage Seal stud penetrations in kitchen & master bed return air plenums Provide LIBs per plan Provide CS-PF wall bracing @ breakfast, office/den,per plan detail A4? Provide fire blocking great room SE corner Secure & shield CSST at fireplace Seal fire blocking lid of fireplace Protect NM conductors at kitchen island Address rafters landing on blocks not continuous plate throughput Nail abutting studs at intersecting wall corners per code Fire block chase near master shower Address (2) 24" LVLs above great room plan shows (3) 18" LVLs Identify ufer ground (green tape both ends) Install eggress windows basement Provide anchor bolts within 12" of plate break north basement wall Provide steel straps at stairs per plan Nail exterior wall sheathing per code
Erosion Control Inspection Residential Failed 8/26/2021 08/26/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/26/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
All Rough Inspection - Residential Not Ready 8/26/2021 8/26/2021 08/26/2021
Miscellaneous Correction
Corrective Action Required
08/13/2021
Provide 5/8 anchor bolts with double bottom plate per plan detail A1 ( tighten anchor bolts) Fasten top plate to header with 2 rows 16d sinkers at 3" OC portal frame garage Solid block sheathing breaks and nail per code ( office/ den ) Provide midpoint support vertical DWV 2" & smaller Seal all upward & exterior penetrations throughout Fire block chases in garage Provide LIBs per plan Provide CS-PF wall bracing @ breakfast, office/den,per plan detail A4? Provide fire blocking great room SE corner Secure & shield CSST at fireplace Address rafters landing on blocks not continuous plate throughput Nail abutting studs at intersecting wall corners per code Address (2) 24" LVLs above great room plan shows (3) 18" LVLs Install eggress windows basement Provide anchor bolts within 12" of plate break north basement wall Provide steel straps at stairs per plan Nail exterior wall sheathing per code
All Rough Inspection - Residential Not Ready 9/1/2021 9/1/2021 09/01/2021
Miscellaneous Correction
Corrective Action Required
08/26/2021
Provide 5/8 anchor bolts with double bottom plate per plan detail A1 ( tighten anchor bolts) Fasten top plate to header with 2 rows 16d sinkers at 3" OC portal frame garage Solid block sheathing breaks and nail per code ( office/ den ) Provide midpoint support vertical DWV 2" & smaller Seal all upward & exterior penetrations throughout Fire block chases in garage Provide LIBs per plan Provide CS-PF wall bracing @ breakfast, office/den,per plan detail A4? Provide fire blocking great room SE corner Secure & shield CSST at fireplace Address rafters landing on blocks not continuous plate throughput Nail abutting studs at intersecting wall corners per code Address (2) 24" LVLs above great room plan shows (3) 18" LVLs Install eggress windows basement Provide anchor bolts within 12" of plate break north basement wall Provide steel straps at stairs per plan Nail exterior wall sheathing per code NOTE: hammer arrestors in wall laundry room
All Rough Inspection - Residential Failed 9/10/2021 9/10/2021 09/10/2021
Miscellaneous Correction
Corrective Action Required
09/01/2021
Secure & shield CSST at fireplace COF NOTE: hammer arrestors in wall laundry room
Electrical Service Inspection Passed 9/10/2021 09/10/2021
Gas Service Inspection - Residential Passed 9/10/2021 09/10/2021
All Rough Inspection - Residential Passed 9/16/2021 9/16/2021 09/16/2021
Miscellaneous Correction
Informational
09/16/2021
NOTE: hammer arrestors in wall laundry room
Driveway Inspection Partial 9/16/2021 9/16/2021 09/16/2021
Misc
Informational
09/16/2021
Driveway is at the 36” max. Forms were place and rock was compacted.
Driveway Inspection Passed 9/24/2021 9/24/2021 09/24/2021
Misc
Informational
09/16/2021
Driveway is at the 36” max. Forms were place and rock was compacted.
Misc
Informational
09/24/2021
9-24-21 10:56 expansion joint at 11ft easement and curb line
Occupancy Inspection - Codes Residential Failed 5/13/2022 5/13/2022 05/13/2022
Miscellaneous Correction
Corrective Action Required
05/13/2022
OBTAIN LAWN IRRIGATION PERMIT SUBMIT BACK FLOW CERTIFICATION . ok for tco if needed
Erosion Control Inspection Residential Passed 06/30/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/26/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
Plot Plan Inspection Passed 06/30/2022
Occupancy Inspection - Codes Residential Full C of O 6/30/2022 6/30/2022 06/30/2022
Miscellaneous Correction
Resolved
06/30/2022
Documents & Images
Date Uploaded File Type Document Name
12/28/2020 Application Form APPLICATION
12/28/2020 Plans plans
12/29/2020 Letter Codes Residential Plan Review
12/30/2020 Plot Plan APPROVED PLOT PLAN
01/12/2021 Approved Plans APPROVED PLANS
01/25/2021 SF-7015 (LOT 74) Siding Revised
03/03/2021 Receipt Receipt for transaction:2021-001029
03/03/2021 Letter DS Building Permit
03/03/2021 Letter INSPECTION SUMMARY
03/29/2021 Letter INSPECTION SUMMARY
03/30/2021 Letter INSPECTION SUMMARY
03/30/2021 Letter INSPECTION SUMMARY
06/23/2021 341 NW Ambersham Dr Deck Pier Inspection Report
06/23/2021 Letter INSPECTION SUMMARY
08/09/2021 Letter INSPECTION SUMMARY
08/13/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
09/01/2021 Letter INSPECTION SUMMARY
09/04/2021 341 Ambersham LVL Report
09/10/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/16/2021 Receipt Receipt for transaction:2021-007373
09/16/2021 Letter INSPECTION SUMMARY
09/16/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
02/11/2022 Letter Codes 140 Day Letter
03/23/2022 Letter Codes 180 Day Letter
05/13/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter Field Certificate of Occupancy
06/30/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home