Permit Application Status

PRRES20204576


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20204576
Building Permit - Residential
Certificate of Occupancy
D AND D BUILDING INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
12/02/2020
01/11/2021
06/26/2021
09/28/2022
Locations
Contacts
D AND D BUILDING INC, Address:PO BOX 7014, Phone:(816) 491-2125  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
TEAGUE ELECTRIC CONSTRUCTION INC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
DANDDBUILDINGCO@GMAIL.COM  
D AND D BUILDING INC, Address:1100 NE DELTA SCHOOL RD  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 12/30/2020 12/28/2020
Brandon Kalwei
Residential Plan Review Approved 12/30/2020 12/28/2020
Brandon Kalwei
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
12/28/2020

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) - detectors not found on 1st floor.
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
12/28/2020

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
34 Specify type of wall bracing method(s) utilized.
Corrective Action Required
12/28/2020

Specify type of wall bracing method(s) utilized. (IRC Section R602.10)
Plot Plan Review Approved 12/04/2020 12/03/2020
Brandon Kalwei
Residential Plan Review Rejected 12/04/2020 12/02/2020
Brandon Kalwei
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
12/02/2020

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) - detectors not found on 1st floor.
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
12/02/2020

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
34 Specify type of wall bracing method(s) utilized.
Corrective Action Required
12/02/2020

Specify type of wall bracing method(s) utilized. (IRC Section R602.10)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,007.15 $1,007.15 Paid 01/11/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 01/11/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/11/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/11/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 01/11/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 01/11/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $150.00 $150.00 Paid 09/28/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/26/2021 (Ready Now) 1/26/2021 01/26/2021
Underslab Plumbing Inspection - Residential Passed 3/2/2021 03/02/2021
Erosion Control Inspection Residential Failed 3/2/2021 03/02/2021
Misc
Corrective Action Required
03/02/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -immediate street cleanup required -provide and maintain gravel filter -no further inspections until issues are resolved
Miscellaneous Inspection Failed 3/2/2021 03/02/2021
Misc
Corrective Action Required
03/02/2021
Post site address
Erosion Control Inspection Residential Failed 3/17/2021 03/17/2021
Misc
Partial Correction
03/17/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -immediate street cleanup required -no further inspections until issues are resolved
Misc
Informational
03/17/2021
First notification 03/02/2021 Second notification 03/17/2021 Stop work order will be issued if not resolved within 48 hours
Miscellaneous Inspection Passed 3/17/2021 03/17/2021
Misc
Resolved
03/17/2021
Post site address
Sewer Service Inspection - R Passed 3/26/2021 (1:00) 3/26/2021 03/26/2021
Water Service Inspection - R Passed 3/30/2021 03/30/2021
All Rough Inspection - Residential Failed 5/12/2021 5/12/2021 05/12/2021
Misc
Corrective Action Required
05/12/2021
Inspection denied due to lack of compliance with erosion control inspection reports
Erosion Control Inspection Residential Failed 3/17/2021 05/12/2021
Misc
Partial Correction
03/17/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -immediate street cleanup required -Remove debris from storm water inlet -no further inspections until issues are resolved
Misc
Resolved
05/12/2021
First notification 03/02/2021 Second notification 03/17/2021 Stop work order will be issued if not resolved within 48 hours
Erosion Control Inspection Residential Failed 5/12/2021 05/18/2021
Misc
Partial Correction
05/12/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -immediate street cleanup required -Remove debris from storm water inlet -no further inspections until issues are resolved FINAL NOTICE, STOP WORK ORDER WILL BE ISSUED IN 48 HOURS IF ISSUES ARE NOT RESOLVED
Electrical Service Inspection Failed 7/22/2021 7/22/2021 07/22/2021
Misc
Corrective Action Required
07/22/2021
-Install a #4 cu bonding jumper from the grounding bus bar, where the GEC is connected to, to the service grounded bus bar -Can only have one conductor at grounding clamp. Install a separate bonding clamp for the gas bonding conductor
Gas Service Inspection - Residential Failed 7/22/2021 7/22/2021 07/22/2021
Misc
Corrective Action Required
07/22/2021
-Provide min ten psi pressure for testing
All Rough Inspection - Residential Failed 7/22/2021 7/22/2021 07/22/2021
Misc
Corrective Action Required
05/12/2021
-Nail exterior wall sheathing per code -Support valley rafters above great room to beam, not ceiling joists -Secure CSST gas line every 32” inside fireplace space -Complete fireplace flue through roof; complete framing and secure fireplace to framing -Install full stud support for the lvl beam near the stair to concrete pad below -Block basement walkout door jamb stud per security code -Install a wall receptacle for useable wall space wider than 2 ft outside basement bedroom -Support gas piping no more than ten ft apart at east side of basement -Install missing I beam support column at basement bathroom wall per plan -Provide CSPF framing where required per A/4 on the plan (rear dining, master bedroom walls) -Brace interior walls per plan -Have engineer address support of the 16” lvl point load at foyer wall. It currently bearing on subfloor only **OK TO INSULATE
All Rough Inspection - Residential Failed 8/6/2021 08/06/2021
Misc
Corrective Action Required
07/22/2021
-Nail exterior wall sheathing per code -Support valley rafters above great room to beam, not ceiling joists -Provide CSPF framing where required per A/4 on the plan (rear dining, master bedroom walls) -Brace interior walls per plan -Have engineer address support of the 16” lvl point load at foyer wall. It currently bearing on subfloor only **OK TO INSULATE
All Rough Inspection - Residential Failed 8/24/2021 08/24/2021
Misc
Corrective Action Required
08/06/2021
-Provide CSPF framing where required per A/4 on the plan (rear dining, master bedroom walls), nail off all metal straps, nail exterior sheathing per CS-PF design -Have engineer address support of the 16” lvl point load at foyer wall. It currently bearing on subfloor only **OK TO INSULATE
Gas Service Inspection - Residential Passed 10/8/2021 10/8/2021 10/08/2021
Misc
Resolved
10/08/2021
-Provide min ten psi pressure for testing
Electrical Service Inspection Passed 10/8/2021 10/8/2021 10/08/2021
Misc
Resolved
10/08/2021
-Install a #4 cu bonding jumper from the grounding bus bar, where the GEC is connected to, to the service grounded bus bar -Can only have one conductor at grounding clamp. Install a separate bonding clamp for the gas bonding conductor
All Rough Inspection - Residential Passed 10/8/2021 10/8/2021 10/08/2021
Misc
Resolved
10/08/2021
-Provide CSPF framing where required per A/4 on the plan (rear dining, master bedroom walls), nail off all metal straps, nail exterior sheathing per CS-PF design -Have engineer address support of the 16” lvl point load at foyer wall. It currently bearing on subfloor only **OK TO INSULATE
Misc
Resolved
10/08/2021
5th rough 3 fees added MARK HARDING 10/08/2021 7:14 AM
Driveway Inspection Partial 12/27/2021 12/27/2021 12/27/2021
Misc
Informational
12/27/2021
Driveway was framed up with aggregate in and compacted. 12/27/21 ES
Sidewalk Inspection Partial 12/27/2021 12/27/2021 12/27/2021
Misc
Informational
12/27/2021
Sidewalk was framed up with aggregate in and compacted. 12/27/21 ES
Erosion Control Inspection Residential Failed 3/24/2022 03/24/2022
Misc
Resolved
03/24/2022
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -immediate street cleanup required -Remove debris from storm water inlet -no further inspections until issues are resolved FINAL NOTICE, STOP WORK ORDER WILL BE ISSUED IN 48 HOURS IF ISSUES ARE NOT RESOLVED
DCM5 ESC INSP DENIED
Corrective Action Required
03/24/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. see back of lot
Occupancy Inspection - Codes Residential Failed 3/24/2022 3/24/2022 03/24/2022
Misc
Corrective Action Required
03/24/2022
inspection denied due to erosion control not in compliance.
Plot Plan Inspection Passed 4/1/2022 04/01/2022
Erosion Control Inspection Residential Failed 4/1/2022 04/01/2022
DCM5 ESC INSP DENIED
Resolved
04/01/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. see back of lot
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/01/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 4/1/2022 4/1/2022 04/01/2022
Misc
Resolved
04/01/2022
inspection denied due to erosion control not in compliance.
Misc
Corrective Action Required
04/01/2022
-erosion control to be in compliance at time of re-inspection -pay all fees -final grade and sod -Splash blocks and sump pump discharge to extend 36” from foundation -water meter to be 14-18” from meter lid to well lid meter must maintain clearance underneath to remain serviceable -address piers poured without inspection -obtain lawn irrigation permit -secondary locking device at back sliding door -spark rings for kitchen countertop outlets as required by code -label all non-GFCI outlets in unfinished spaces -garage stair hand rail must comply with irc code section R311.7.8.1
Occupancy Inspection - Codes Residential Failed 4/15/2022 4/15/2022 04/15/2022
Misc
Corrective Action Required
04/01/2022
-pay all fees -water meter to be 14-18” from meter lid to well lid meter must maintain clearance underneath to remain serviceable -address piers poured without inspection -address siding from grade at back of lot, wood siding must maintain 6" clearance from ground -secondary locking device at back sliding door -spark rings for kitchen countertop outlets as required by code -label all non-GFCI outlets in unfinished spaces -garage stair hand rail must comply with irc code section R311.7.8.1
Piers/Caissons Inspection - Residential Passed 5/4/2022 05/04/2022
Erosion Control Inspection Residential Passed 5/4/2022 05/04/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/01/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 5/4/2022 5/4/2022 05/04/2022
Misc
Corrective Action Required
04/15/2022
-pay all fees -address siding from grade at back of lot, wood siding must maintain 6" clearance from ground -secondary locking device at back sliding door -spark rings for kitchen countertop outlets -label all non-GFCI outlets in unfinished spaces
Misc
Informational
05/04/2022
Home fully staged and occupied with people touring for parade of homes. Homes has not been given a occupancy.
Occupancy Inspection - Codes Residential Failed 9/28/2022 9/28/2022 09/28/2022
Misc
Corrective Action Required
05/04/2022
-pay all fees -spark rings for kitchen countertop outlets
Misc
Informational
05/04/2022
Home fully staged and occupied with people touring for parade of homes. Homes has not been given a occupancy.
Occupancy Inspection - Codes Residential Full C of O 9/28/2022 09/28/2022
Misc
Resolved
09/28/2022
-pay all fees -spark rings for kitchen countertop outlets
Misc
Resolved
09/28/2022
Home fully staged and occupied with people touring for parade of homes. Homes has not been given a occupancy.
Documents & Images
Date Uploaded File Type Document Name
12/02/2020 Plans HOUSE PLANS
12/02/2020 Application Form APPLICATION
12/02/2020 Plot Plan PLOT PLAN
12/03/2020 Letter Codes Residential Plan Review
01/11/2021 Receipt Receipt for transaction:2021-000144
01/11/2021 Letter DS Building Permit
01/20/2021 Approved Plans APPROVED PLANS
01/26/2021 Plot Plan APPROVED PLOT PLAN
01/26/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/17/2021 Letter INSPECTION SUMMARY
03/17/2021 Letter INSPECTION SUMMARY
03/26/2021 Letter INSPECTION SUMMARY
03/30/2021 Letter INSPECTION SUMMARY
05/12/2021 Letter INSPECTION SUMMARY
05/12/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
08/24/2021 Letter INSPECTION SUMMARY
10/04/2021 DD-7167 Lot 32 Whispering Woods Inspection Item
10/08/2021 Letter INSPECTION SUMMARY
10/08/2021 Letter INSPECTION SUMMARY
10/08/2021 Letter INSPECTION SUMMARY
12/27/2021 Letter INSPECTION SUMMARY
12/27/2021 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
09/21/2022 Letter Codes 140 Day Letter
09/28/2022 Receipt Receipt for transaction:2022-007871
09/28/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter Codes Final Certificate of Occupancy
09/28/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents