Permit Application Status

PRRES20204450


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20204450
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - FINISHED AND UNFINISHED BASEMENT STOP WORK ORDER generated on 04/23/2021 12:00 AM by username 'Mark Harding'. STOP WORK ORDER removed on 04/23/2021 12:00 AM by username 'Michael Harkins'.
11/24/2020
12/18/2020
12/07/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
PERMITTING@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review (RES) Approved 12/17/2020 12/17/2020
Shannon McGuire
Plot Plan Review Approved 11/30/2020 12/17/2020
Brandon Kalwei
Residential Plan Review Approved 11/30/2020 12/15/2020
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,125.02 $1,125.02 Paid 12/18/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 12/18/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/18/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/18/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 12/18/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 12/18/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/06/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/06/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/06/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/06/2021
Outstanding Fees Amount Paid Owing Date Paid
9110080-Not Ready Inspection Fee $50.00 $0.00 $50.00 Not Paid


$50.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 2/18/2021 (1:00) 2/18/2021 02/18/2021
Underslab Plumbing Inspection - Residential Failed 2/24/2021 2/24/2021 02/24/2021
Misc
Corrective Action Required
02/24/2021
- COMPLETE CONNECTION OF INTERIOR UNDERSLAB DRAIN TILE TO SUMP -
Water Service Inspection - R Passed 2/24/2021 (1:00) 2/24/2021 02/24/2021
Footing Inspection - Residential Failed 2/25/2021 02/25/2021
Misc
Corrective Action Required
02/25/2021
- NO FOOTING INSPECTION ON RECORD SUBMIT 3RD PARTY INSPECTIONS WITHIN 48 HOURS OF POUR -
Underslab Plumbing Inspection - Residential Passed 2/25/2021 2/25/2021 02/25/2021
Misc
Resolved
02/25/2021
Erosion Control Inspection Residential Failed 2/25/2021 02/25/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/25/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - PROVIDE GRAVEL FILTER AT DRIVEWAY - - PROVIDE SILT FENCE -
All Rough Inspection - Residential Failed - Stop Work 4/23/2021 4/23/2021 04/23/2021
Misc
Corrective Action Required
04/23/2021
Stop construction posted. inspections denied. no footing inspection provided.
Footing Inspection - Residential Passed 4/23/2021 04/23/2021
Misc
Corrective Action Required
02/25/2021
- NO FOOTING INSPECTION ON RECORD SUBMIT 3RD PARTY INSPECTIONS WITHIN 48 HOURS OF POUR -
Misc
Corrective Action Required
04/23/2021
3RD PARTY FOOTING BY DEREK PEREZ @ RES SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATION SOUTH EAST (REAR LEFT) CORNER OF GARAGE FOUNDATION WALL
Gas Service Inspection - Residential Passed 4/27/2021 4/27/2021 04/27/2021
Electrical Service Inspection Passed 4/27/2021 4/27/2021 04/27/2021
All Rough Inspection - Residential Failed 4/27/2021 4/27/2021 04/27/2021
Misc
Resolved
04/27/2021
Stop construction posted. inspections denied. no footing inspection provided.
Misc
Corrective Action Required
04/27/2021
Provide fire resistive rating for exterior wall projection on east & west side of house, less than 5' from property line, no soffit vents in these areas ( 2018 IRC R302.1 Provide truss screws / H2.5 dbl hip girder A-1 at fireplace Provide LTHJA26 hangers trusses CJ-1 CJ-2 per truss plans Nail stud to stud at intersecting wall corners ( at braced wall panels #9 S1.0) South basement corners Nail structural panel wall sheathing per code ( Plans call for nails not staples ) Seal exterior penetration bed #3 closet Seal top Plate penetrations bed # 2 Tighten anchor bolts garage Complete nailing STHD14 west side Provide 5/8 anchor bolts per PFH portal frame detail Provide Tyvek tape over nail penetrations in Tyvek at PFH portal frame Provide H2.5 / truss screws at dbl girder E-3 At radon line to roof garage Provide lateral truss bracing per truss plans Provide joist hangers rec room / storage at cantilever Provide 2 studs under double joist storage room Seal fire blocking at top plate basement furr out Fire block beams at columns & beam pockets Apply sheathing to interior side of wall extend braced wall panels into interior edge of wall per plan at walkout Tighten anchor bolts basement Support pex at bath #3 vanity
All Rough Inspection - Residential Not Ready 5/5/2021 5/5/2021 05/05/2021
Misc
Corrective Action Required
04/27/2021
Provide fire resistive rating for exterior wall projection on east & west side of house, less than 5' from property line, no soffit vents in these areas ( 2018 IRC R302.1) fire caulk & complete solid blocking in corners of soffits Nail stud to stud at intersecting wall corners ( at braced wall panels #9 S1.0) SGD Nail structural panel wall sheathing per code ( Plans call for nails not staples) Tighten anchor bolts garage Seal fire blocking at top plate basement furr out Fire block beams at columns & beam pockets
All Rough Inspection - Residential Failed 5/13/2021 5/13/2021 05/13/2021
Misc
Corrective Action Required
05/05/2021
Tyvek tape nails sheathing Provide 1 1/2 bearing deck beam Ok to insulate
All Rough Inspection - Residential Failed 5/17/2021 5/17/2021 05/17/2021
Misc
Corrective Action Required
05/13/2021
Tyvek tape nails sheathing PFH PORTAL FRAME COMPLETE. STILL NAIL PENETRATIONS GARAGE, FRONT BEDROOM, DECK Provide 1 1/2 bearing deck beam ROOF OK. CEDAR POST UNDER DECK BEAM ? Ok to insulate
Driveway Inspection Partial 5/21/2021 05/21/2021
Misc
Informational
05/21/2021
JJACKSON Driveway 5/21/21 Forms and materials passed pre-inspection.
All Rough Inspection - Residential Not Ready 5/26/2021 5/26/2021 05/26/2021
Misc
Corrective Action Required
05/17/2021
Tyvek tape nail penetrations in tyvek wrap STILL NAIL PENETRATIONS FRONT BEDROOM, DECK & BRACED WALL PANELS Provide 1 1/2 bearing deck beam OR LEDGER LOCK SIDES TO HOUSE PER CODE AND USE SIMPSON CONCEALED FLANG DOUBLE JOIST HANGER HUC212-2 OR EQUIVALENT : Ok to insulate :
Driveway Inspection Failed 5/28/2021 5/28/2021 05/28/2021
Misc
Informational
05/21/2021
JJACKSON Driveway 5/21/21 Forms and materials passed pre-inspection.
Misc
Corrective Action Required
05/28/2021
Finished driveway is out of ADA tolerance and needs to be replaced. RP 5-28-21
All Rough Inspection - Residential Failed 6/8/2021 6/8/2021 06/08/2021
Misc
Corrective Action Required
05/26/2021
Provide 1 1/2 bearing deck beam OR LEDGER LOCK SIDES TO HOUSE PER CODE AND USE SIMPSON CONCEALED FLANG DOUBLE JOIST HANGER HUC212-2 OR EQUIVALENT : Ok to insulate :
All Rough Inspection - Residential Passed 6/23/2021 6/23/2021 06/23/2021
Misc
Resolved
06/23/2021
Sidewalk Inspection Partial 7/19/2021 7/19/2021 07/19/2021
Misc
Informational
07/19/2021
Sidewalk was formed and rock was compacted. Also made them clean up in front of the house before passing the pre-pour. The forms appear to meed ADA standards.
Driveway Inspection Passed 7/21/2021 07/21/2021
Misc
Informational
05/28/2021
JJACKSON Driveway 5/21/21 Forms and materials passed pre-inspection.
Misc
Corrective Action Required
05/28/2021
Finished driveway is out of ADA tolerance and needs to be replaced. RP 5-28-21
Misc
Informational
07/21/2021
Met with Steve Robbins to discuss the driveway and sidewalk. Even though it is technically out of spec, we decided to pass it this time. RP 7-21-21
Occupancy Inspection - Codes Residential Not Ready 9/23/2021 9/23/2021 09/23/2021
Occupancy Inspection - Codes Residential Not Ready 9/27/2021 9/27/2021 09/27/2021
Piers/Caissons Inspection - Residential Passed 10/1/2021 10/01/2021
Misc
Informational
10/01/2021
3RD PARTY BY RES ON FOOTING REPORT
Occupancy Inspection - Codes Residential Failed 10/1/2021 10/1/2021 10/01/2021
Misc
Corrective Action Required
10/01/2021
Pay outstanding fees Sidewalk inspection pending Remove dust covers smoke detectors Provide self closing door garage A 4" sphere shall not pass through stair spindles Provide back-flow device at water shut off Provide two 3" screws in each exterior door hinge & strike plate patio door Sump & drain tile shall discharge 36" from foundation Provide splash blocks where missing 7 3/4 max riser at bottom of deck stairs Deck handrail height shall be between 34" -38" DO NOT MOVE FURNITURE INTO A HOUSE WITHOUT OCCUPANCY INSPECTION / TCO
Occupancy Inspection - Codes Residential Not Ready 11/2/2021 11/2/2021 11/02/2021
Misc
Corrective Action Required
10/01/2021
Sidewalk inspection pending Remove dust covers smoke detectors Provide back-flow device at water shut off ( anti siphon device still missing ) 7 3/4 max riser at bottom of deck stairs DO NOT MOVE FURNITURE INTO A HOUSE WITHOUT OCCUPANCY INSPECTION / TCO
Occupancy Inspection - Codes Residential Temporary C of O 11/11/2021 11/11/2021 11/11/2021
Misc
Corrective Action Required
11/02/2021
Sidewalk inspection pending TCO until 11/21/2021
Sidewalk Inspection Passed 12/2/2021 12/2/2021 12/02/2021
Misc
Informational
12/02/2021
Sidewalk meets LS and ADA specs. RP 12-2-21
Occupancy Inspection - Codes Residential Full C of O 12/7/2021 12/7/2021 12/07/2021
Misc
Resolved
12/07/2021
TCO until 11/21/2021
Plot Plan Inspection Passed 1/11/2022 01/11/2022
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: